Cargando…
Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection
Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427398/ https://www.ncbi.nlm.nih.gov/pubmed/37276437 http://dx.doi.org/10.1002/advs.202301207 |
_version_ | 1785090230350512128 |
---|---|
author | Suter, Benjamin Anthis, Alexandre H. C. Zehnder, Anna‐Katharina Mergen, Victor Rosendorf, Jachym Gerken, Lukas R. H. Schlegel, Andrea A. Korcakova, Eva Liska, Vaclav Herrmann, Inge K. |
author_facet | Suter, Benjamin Anthis, Alexandre H. C. Zehnder, Anna‐Katharina Mergen, Victor Rosendorf, Jachym Gerken, Lukas R. H. Schlegel, Andrea A. Korcakova, Eva Liska, Vaclav Herrmann, Inge K. |
author_sort | Suter, Benjamin |
collection | PubMed |
description | Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive, dual modality, electronic‐free, leak sensor system integrable into surgical adhesive suture support materials is introduced. Leak sensors contain high atomic number carbonates embedded in a polyacrylamide matrix, that upon exposure to gastric fluid convert into gaseous carbon dioxide (CO(2)). CO(2) bubbles remain entrapped in the hydrogel matrix, leading to a distinctly increased echogenic contrast detectable by a low‐cost and portable ultrasound transducer, while the dissolution of the carbonate species and the resulting diffusion of the cation produces a markedly reduced contrast in computed tomography imaging. The sensing elements can be patterned into a variety of characteristic shapes and can be combined with nonreactive tantalum oxide reference elements, allowing the design of shape‐morphing sensing elements visible to the naked eye as well as artificial intelligence‐assisted automated detection. In summary, shape‐morphing dual modality sensors for the early and robust detection of postoperative complications at deep tissue sites, opening new routes for postoperative patient surveillance using existing hospital infrastructure is reported. |
format | Online Article Text |
id | pubmed-10427398 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104273982023-08-17 Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection Suter, Benjamin Anthis, Alexandre H. C. Zehnder, Anna‐Katharina Mergen, Victor Rosendorf, Jachym Gerken, Lukas R. H. Schlegel, Andrea A. Korcakova, Eva Liska, Vaclav Herrmann, Inge K. Adv Sci (Weinh) Research Articles Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive, dual modality, electronic‐free, leak sensor system integrable into surgical adhesive suture support materials is introduced. Leak sensors contain high atomic number carbonates embedded in a polyacrylamide matrix, that upon exposure to gastric fluid convert into gaseous carbon dioxide (CO(2)). CO(2) bubbles remain entrapped in the hydrogel matrix, leading to a distinctly increased echogenic contrast detectable by a low‐cost and portable ultrasound transducer, while the dissolution of the carbonate species and the resulting diffusion of the cation produces a markedly reduced contrast in computed tomography imaging. The sensing elements can be patterned into a variety of characteristic shapes and can be combined with nonreactive tantalum oxide reference elements, allowing the design of shape‐morphing sensing elements visible to the naked eye as well as artificial intelligence‐assisted automated detection. In summary, shape‐morphing dual modality sensors for the early and robust detection of postoperative complications at deep tissue sites, opening new routes for postoperative patient surveillance using existing hospital infrastructure is reported. John Wiley and Sons Inc. 2023-06-05 /pmc/articles/PMC10427398/ /pubmed/37276437 http://dx.doi.org/10.1002/advs.202301207 Text en © 2023 The Authors. Advanced Science published by Wiley‐VCH GmbH https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Suter, Benjamin Anthis, Alexandre H. C. Zehnder, Anna‐Katharina Mergen, Victor Rosendorf, Jachym Gerken, Lukas R. H. Schlegel, Andrea A. Korcakova, Eva Liska, Vaclav Herrmann, Inge K. Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title | Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title_full | Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title_fullStr | Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title_full_unstemmed | Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title_short | Surgical Sealant with Integrated Shape‐Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection |
title_sort | surgical sealant with integrated shape‐morphing dual modality ultrasound and computed tomography sensors for gastric leak detection |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427398/ https://www.ncbi.nlm.nih.gov/pubmed/37276437 http://dx.doi.org/10.1002/advs.202301207 |
work_keys_str_mv | AT suterbenjamin surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT anthisalexandrehc surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT zehnderannakatharina surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT mergenvictor surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT rosendorfjachym surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT gerkenlukasrh surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT schlegelandreaa surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT korcakovaeva surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT liskavaclav surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection AT herrmanningek surgicalsealantwithintegratedshapemorphingdualmodalityultrasoundandcomputedtomographysensorsforgastricleakdetection |