Cargando…
Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights
Multi-detector computed tomography (MDCT) is the gold standard non-invasive tool for evaluating aortic root dimensions. We assessed the agreement between 4D TEE and MDCT-derived aortic valve annular dimensions, coronary ostia height, and minor dimensions of sinuses of Valsalva (SoV) and sinotubular...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427530/ https://www.ncbi.nlm.nih.gov/pubmed/37269399 http://dx.doi.org/10.1007/s10554-023-02873-3 |
_version_ | 1785090263677403136 |
---|---|
author | Hassan, Mohamed Abdrabou, Mostafa M. Wahba, Wasseem Amin Samaan, Amir Anwar Baghdady, Yasser Elamragy, Ahmed A. |
author_facet | Hassan, Mohamed Abdrabou, Mostafa M. Wahba, Wasseem Amin Samaan, Amir Anwar Baghdady, Yasser Elamragy, Ahmed A. |
author_sort | Hassan, Mohamed |
collection | PubMed |
description | Multi-detector computed tomography (MDCT) is the gold standard non-invasive tool for evaluating aortic root dimensions. We assessed the agreement between 4D TEE and MDCT-derived aortic valve annular dimensions, coronary ostia height, and minor dimensions of sinuses of Valsalva (SoV) and sinotubular junction (STJ). In this prospective analytical study, we measured the annular area, annular perimeter, area-derived diameter, area-derived perimeter, left and right coronary ostial heights, and minor diameters of the SoV and the STJ using ECG-gated MDCT and 4D TEE. TEE measurements were calculated semi-automatically by the eSie valve software. We enrolled 43 adult patients (27 males, median age: 46 years). We found strong correlations and good agreement between the two modalities in annular dimensions (area, perimeter, area-derived diameter, and perimeter-derived diameter), left coronary ostial height, minimum STJ diameter, and minimum SoV diameters. Moderate correlations, and agreement, with relatively large differences between the 95% LOA, were demonstrated for the right coronary artery ostial height. 4D TEE correlates well with MDCT in measuring aortic annular dimensions, coronary ostial height, SoV minor diameter, and sinotubular junction minor diameter. Whether this can affect clinical outcomes is unknown. It could replace MDCT if the latter is unavailable or contraindicated. |
format | Online Article Text |
id | pubmed-10427530 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-104275302023-08-17 Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights Hassan, Mohamed Abdrabou, Mostafa M. Wahba, Wasseem Amin Samaan, Amir Anwar Baghdady, Yasser Elamragy, Ahmed A. Int J Cardiovasc Imaging Original Paper Multi-detector computed tomography (MDCT) is the gold standard non-invasive tool for evaluating aortic root dimensions. We assessed the agreement between 4D TEE and MDCT-derived aortic valve annular dimensions, coronary ostia height, and minor dimensions of sinuses of Valsalva (SoV) and sinotubular junction (STJ). In this prospective analytical study, we measured the annular area, annular perimeter, area-derived diameter, area-derived perimeter, left and right coronary ostial heights, and minor diameters of the SoV and the STJ using ECG-gated MDCT and 4D TEE. TEE measurements were calculated semi-automatically by the eSie valve software. We enrolled 43 adult patients (27 males, median age: 46 years). We found strong correlations and good agreement between the two modalities in annular dimensions (area, perimeter, area-derived diameter, and perimeter-derived diameter), left coronary ostial height, minimum STJ diameter, and minimum SoV diameters. Moderate correlations, and agreement, with relatively large differences between the 95% LOA, were demonstrated for the right coronary artery ostial height. 4D TEE correlates well with MDCT in measuring aortic annular dimensions, coronary ostial height, SoV minor diameter, and sinotubular junction minor diameter. Whether this can affect clinical outcomes is unknown. It could replace MDCT if the latter is unavailable or contraindicated. Springer Netherlands 2023-06-03 2023 /pmc/articles/PMC10427530/ /pubmed/37269399 http://dx.doi.org/10.1007/s10554-023-02873-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Hassan, Mohamed Abdrabou, Mostafa M. Wahba, Wasseem Amin Samaan, Amir Anwar Baghdady, Yasser Elamragy, Ahmed A. Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title | Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title_full | Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title_fullStr | Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title_full_unstemmed | Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title_short | Agreement between 4D transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
title_sort | agreement between 4d transesophageal echocardiography and multi-detector computed tomography in measuring aortic root dimensions and coronary ostia heights |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427530/ https://www.ncbi.nlm.nih.gov/pubmed/37269399 http://dx.doi.org/10.1007/s10554-023-02873-3 |
work_keys_str_mv | AT hassanmohamed agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights AT abdraboumostafam agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights AT wahbawasseemamin agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights AT samaanamiranwar agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights AT baghdadyyasser agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights AT elamragyahmeda agreementbetween4dtransesophagealechocardiographyandmultidetectorcomputedtomographyinmeasuringaorticrootdimensionsandcoronaryostiaheights |