Cargando…

A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining

Whole mount zebrafish antibody staining (ABS) is a common staining technique used to localize protein information in a zebrafish embryo or larva. Like most biological assays, the whole mount zebrafish ABS is still largely conducted manually through labor intensive and time-consuming steps which affe...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Songtao, Chin, Wei-Chun, Ni, Chih-Wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427545/
https://www.ncbi.nlm.nih.gov/pubmed/37581716
http://dx.doi.org/10.1007/s10544-023-00670-2
_version_ 1785090267406139392
author Ye, Songtao
Chin, Wei-Chun
Ni, Chih-Wen
author_facet Ye, Songtao
Chin, Wei-Chun
Ni, Chih-Wen
author_sort Ye, Songtao
collection PubMed
description Whole mount zebrafish antibody staining (ABS) is a common staining technique used to localize protein information in a zebrafish embryo or larva. Like most biological assays, the whole mount zebrafish ABS is still largely conducted manually through labor intensive and time-consuming steps which affect both consistency and throughput of the assay. In this work, we develop a milli fluidic device that can automatically trap and immobilize the fixed chorion-less zebrafish embryos for the whole mount ABS. With just a single loading step, the zebrafish embryos can be trapped by the milli fluidic device through a chaotic hydrodynamic trapping process. Moreover, a consistent body orientation (i.e., head point inward) for the trapped zebrafish embryos can be achieved without additional orientation adjustment device. Furthermore, we employed a consumer-grade SLA 3D printer assisted method for device prototyping which is ideal for labs with limited budgets. Notably, the milli fluidic device has enabled the optimization and successful implementation of whole mount zebrafish Caspase-3 ABS. We demonstrated our device can accelerate the overall procedure by reducing at least 50% of washing time in the standard well-plate-based manual procedure. Also, the consistency is improved, and manual steps are reduced using the milli fluidic device. This work fills the gap in the milli fluidic application for whole mount zebrafish immunohistochemistry. We hope the device can be accepted by the zebrafish community and be used for other types of whole mount zebrafish ABS procedures or expanded to more complicated in situ hybridization (ISH) procedure. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10544-023-00670-2.
format Online
Article
Text
id pubmed-10427545
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-104275452023-08-17 A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining Ye, Songtao Chin, Wei-Chun Ni, Chih-Wen Biomed Microdevices Research Whole mount zebrafish antibody staining (ABS) is a common staining technique used to localize protein information in a zebrafish embryo or larva. Like most biological assays, the whole mount zebrafish ABS is still largely conducted manually through labor intensive and time-consuming steps which affect both consistency and throughput of the assay. In this work, we develop a milli fluidic device that can automatically trap and immobilize the fixed chorion-less zebrafish embryos for the whole mount ABS. With just a single loading step, the zebrafish embryos can be trapped by the milli fluidic device through a chaotic hydrodynamic trapping process. Moreover, a consistent body orientation (i.e., head point inward) for the trapped zebrafish embryos can be achieved without additional orientation adjustment device. Furthermore, we employed a consumer-grade SLA 3D printer assisted method for device prototyping which is ideal for labs with limited budgets. Notably, the milli fluidic device has enabled the optimization and successful implementation of whole mount zebrafish Caspase-3 ABS. We demonstrated our device can accelerate the overall procedure by reducing at least 50% of washing time in the standard well-plate-based manual procedure. Also, the consistency is improved, and manual steps are reduced using the milli fluidic device. This work fills the gap in the milli fluidic application for whole mount zebrafish immunohistochemistry. We hope the device can be accepted by the zebrafish community and be used for other types of whole mount zebrafish ABS procedures or expanded to more complicated in situ hybridization (ISH) procedure. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10544-023-00670-2. Springer US 2023-08-15 2023 /pmc/articles/PMC10427545/ /pubmed/37581716 http://dx.doi.org/10.1007/s10544-023-00670-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Ye, Songtao
Chin, Wei-Chun
Ni, Chih-Wen
A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title_full A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title_fullStr A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title_full_unstemmed A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title_short A multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
title_sort multi-depth spiral milli fluidic device for whole mount zebrafish antibody staining
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427545/
https://www.ncbi.nlm.nih.gov/pubmed/37581716
http://dx.doi.org/10.1007/s10544-023-00670-2
work_keys_str_mv AT yesongtao amultidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining
AT chinweichun amultidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining
AT nichihwen amultidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining
AT yesongtao multidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining
AT chinweichun multidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining
AT nichihwen multidepthspiralmillifluidicdeviceforwholemountzebrafishantibodystaining