Cargando…

Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study

INTRODUCTION: Given the rising prevalence of knee osteoarthritis, radiofrequency ablation of genicular nerves (RFA) has emerged as a promising treatment option for knee pain. The knee has an extremely complex and variable innervation with nearly 13 genicular nerves described. The frequently ablated...

Descripción completa

Detalles Bibliográficos
Autores principales: Kolakkanni, Chinchu, Gonnade, Nitesh Manohar, Gaur, Ravi, Nayyar, Ashish Kumar, Ghuleliya, Rambeer, TK, Abins
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10429091/
https://www.ncbi.nlm.nih.gov/pubmed/37587439
http://dx.doi.org/10.1186/s12891-023-06761-8
_version_ 1785090627269033984
author Kolakkanni, Chinchu
Gonnade, Nitesh Manohar
Gaur, Ravi
Nayyar, Ashish Kumar
Ghuleliya, Rambeer
TK, Abins
author_facet Kolakkanni, Chinchu
Gonnade, Nitesh Manohar
Gaur, Ravi
Nayyar, Ashish Kumar
Ghuleliya, Rambeer
TK, Abins
author_sort Kolakkanni, Chinchu
collection PubMed
description INTRODUCTION: Given the rising prevalence of knee osteoarthritis, radiofrequency ablation of genicular nerves (RFA) has emerged as a promising treatment option for knee pain. The knee has an extremely complex and variable innervation with nearly 13 genicular nerves described. The frequently ablated genicular nerves are the superomedial (SMGN), the superolateral (SLGN), and the inferomedial (IMGN) genicular nerves. Conventionally, under ultrasound guidance, these nerves are ablated near the corresponding arterial pulsations, but due to the rich vascular anastomosis around the knee joint, identifying the arteries corresponding to these constant genicular nerves can be tedious unless guided by some bony landmarks. In this study, we have evaluated whether it is possible to accurately target these three genicular nerves by just locating bony landmarks under ultrasound in human cadaveric knee specimens. METHODS: Fifteen formalin-fixed cadaveric knee specimens were studied. SMGN was targeted 1 cm anterior to the adductor tubercle in the axial view. For SLGN, in the coronal view, the junction of the lateral femoral condyle and shaft was identified, and at the same level in the axial view, the crest between the lateral and posterior femoral cortex was targeted. For IMGN in the coronal view, the midpoint between the most prominent part of the medial tibial condyle and the insertion of the deep fibers of the medial collateral ligament was marked. The medial end of the medial tibial cortex was then targeted at the same level in the axial view. The needle was inserted from anterior to posterior, with an in-plane approach for all nerves. Eosin, 2% W/V, in 0.1 ml was injected. Microdissection was done while keeping the needle in situ. Staining of the nerve was considered a positive outcome, and the percentage was calculated. The nerve-to-needle distance was measured, and the mean with an interquartile range was calculated. RESULT: The accuracies of ultrasound-guided bony landmarks of SMGN, SLGN, and IMGN were 100% in terms of staining, with average nerve-to-needle distances of 1.67, 3.2, and 1.8 mm respectively. CONCLUSION: It is with 100% accuracy, that we can perform RFA of SMGN, SLGN, and IMGN under ultrasound guidance, by locating the aforementioned bony landmarks. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-023-06761-8.
format Online
Article
Text
id pubmed-10429091
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-104290912023-08-17 Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study Kolakkanni, Chinchu Gonnade, Nitesh Manohar Gaur, Ravi Nayyar, Ashish Kumar Ghuleliya, Rambeer TK, Abins BMC Musculoskelet Disord Research INTRODUCTION: Given the rising prevalence of knee osteoarthritis, radiofrequency ablation of genicular nerves (RFA) has emerged as a promising treatment option for knee pain. The knee has an extremely complex and variable innervation with nearly 13 genicular nerves described. The frequently ablated genicular nerves are the superomedial (SMGN), the superolateral (SLGN), and the inferomedial (IMGN) genicular nerves. Conventionally, under ultrasound guidance, these nerves are ablated near the corresponding arterial pulsations, but due to the rich vascular anastomosis around the knee joint, identifying the arteries corresponding to these constant genicular nerves can be tedious unless guided by some bony landmarks. In this study, we have evaluated whether it is possible to accurately target these three genicular nerves by just locating bony landmarks under ultrasound in human cadaveric knee specimens. METHODS: Fifteen formalin-fixed cadaveric knee specimens were studied. SMGN was targeted 1 cm anterior to the adductor tubercle in the axial view. For SLGN, in the coronal view, the junction of the lateral femoral condyle and shaft was identified, and at the same level in the axial view, the crest between the lateral and posterior femoral cortex was targeted. For IMGN in the coronal view, the midpoint between the most prominent part of the medial tibial condyle and the insertion of the deep fibers of the medial collateral ligament was marked. The medial end of the medial tibial cortex was then targeted at the same level in the axial view. The needle was inserted from anterior to posterior, with an in-plane approach for all nerves. Eosin, 2% W/V, in 0.1 ml was injected. Microdissection was done while keeping the needle in situ. Staining of the nerve was considered a positive outcome, and the percentage was calculated. The nerve-to-needle distance was measured, and the mean with an interquartile range was calculated. RESULT: The accuracies of ultrasound-guided bony landmarks of SMGN, SLGN, and IMGN were 100% in terms of staining, with average nerve-to-needle distances of 1.67, 3.2, and 1.8 mm respectively. CONCLUSION: It is with 100% accuracy, that we can perform RFA of SMGN, SLGN, and IMGN under ultrasound guidance, by locating the aforementioned bony landmarks. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-023-06761-8. BioMed Central 2023-08-16 /pmc/articles/PMC10429091/ /pubmed/37587439 http://dx.doi.org/10.1186/s12891-023-06761-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kolakkanni, Chinchu
Gonnade, Nitesh Manohar
Gaur, Ravi
Nayyar, Ashish Kumar
Ghuleliya, Rambeer
TK, Abins
Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title_full Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title_fullStr Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title_full_unstemmed Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title_short Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
title_sort can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10429091/
https://www.ncbi.nlm.nih.gov/pubmed/37587439
http://dx.doi.org/10.1186/s12891-023-06761-8
work_keys_str_mv AT kolakkannichinchu canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy
AT gonnadeniteshmanohar canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy
AT gaurravi canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy
AT nayyarashishkumar canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy
AT ghuleliyarambeer canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy
AT tkabins canultrasoundguidedradiofrequencyablationofgenicularnervesofthekneebeperformedwithoutlocatingcorrespondingarterialpulsationsacadavericstudy