Cargando…

Effects of volume-targeted pressure-controlled inverse ratio ventilation on functional residual capacity and dead space in obese patients undergoing robot-assisted laparoscopic radical prostatectomy

BACKGROUND: The effect of inverse inspiration:expiration (I:E) ratio on functional residual capacity (FRC) during pneumoperitoneum is unclear. We hypothesised that volume-targeted pressure-controlled inverse ratio ventilation (vtPC-IRV) would increase FRC by increasing the level of auto-PEEP in low...

Descripción completa

Detalles Bibliográficos
Autores principales: Hirabayashi, Go, Yokose, Yuuki, Oshika, Hiroyuki, Saito, Minami, Maruyama, Koichi, Andoh, Tomio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10430846/
https://www.ncbi.nlm.nih.gov/pubmed/37588587
http://dx.doi.org/10.1016/j.bjao.2022.100020
Descripción
Sumario:BACKGROUND: The effect of inverse inspiration:expiration (I:E) ratio on functional residual capacity (FRC) during pneumoperitoneum is unclear. We hypothesised that volume-targeted pressure-controlled inverse ratio ventilation (vtPC-IRV) would increase FRC by increasing the level of auto-PEEP in low respiratory compliance situations. METHODS: During robot-assisted laparoscopic radical prostatectomy, 20 obese patients were sequentially ventilated with four different settings for 30 min in each setting: (1) control, I:E ratio of 1:2 and baseline airway pressure (BAP) of 5 cm H(2)O; (2) IRV2, I:E ratio of 2:1 and BAP off; (3) IRV3, I:E ratio of 3:1 and BAP off; and (4) IRV4, I:E ratio of 4:1 and BAP off. The changes in FRC were identified and compared among these settings. RESULTS: The FRC significantly increased as the I:E ratio increased. The FRC values expressed as median (inter-quartile range) during control, IRV2, IRV3, and IRV4 were 1149 (898–1386), 1485 (1018–1717), 1602 (1209–1775), and 1757 (1337–1955) ml, respectively. Auto-PEEP increased significantly as the I:E ratio increased and correlated with FRC (rho=0.303; P=0.006). Shunt and physiological dead space were significantly lower in all IRV groups than in the control group; however, there were no significant differences among the IRV groups. CONCLUSIONS: vtPC-IRV with shortened expiratory time and increased auto-PEEP effectively increases FRC during robot-assisted laparoscopic radical prostatectomy in obese patients. FRC increases progressively as the I:E ratio increases from 1:2 to 4:1; however, an I:E ratio higher than 2:1 does not further improve the dead space. CLINICAL TRIAL REGISTRATION: UMIN000038989.