Cargando…
A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report
The socket-shield technique is considered one of the best treatment modalities that reduce the amount of facial bone loss and gingival recession following tooth extraction. However, the difficulty in preparing the shield by partial tooth extraction makes it technique-sensitive and limits its use. Th...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10431202/ https://www.ncbi.nlm.nih.gov/pubmed/37593187 http://dx.doi.org/10.1093/jscr/rjad464 |
_version_ | 1785091145228877824 |
---|---|
author | Lahham, Cezar Lahham, Elias Edward Ali, Ali Abu |
author_facet | Lahham, Cezar Lahham, Elias Edward Ali, Ali Abu |
author_sort | Lahham, Cezar |
collection | PubMed |
description | The socket-shield technique is considered one of the best treatment modalities that reduce the amount of facial bone loss and gingival recession following tooth extraction. However, the difficulty in preparing the shield by partial tooth extraction makes it technique-sensitive and limits its use. This case report presents a 29-year-old medically fit male patient with a destructed non-vital lateral incisor. It was planned for immediate implant placement in conjunction with the socket-shield technique. The shield was prepared in a new technique using a nickel–titanium endodontic file, which was repeatedly adjusted to increase the diameter of the canal gradually. The canal was enlarged to reach a sufficient diameter to perform root separation safely. Following the shield preparation, immediate implant placement was preformed, and screw-retained temporary crown was done. |
format | Online Article Text |
id | pubmed-10431202 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-104312022023-08-17 A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report Lahham, Cezar Lahham, Elias Edward Ali, Ali Abu J Surg Case Rep Case Report The socket-shield technique is considered one of the best treatment modalities that reduce the amount of facial bone loss and gingival recession following tooth extraction. However, the difficulty in preparing the shield by partial tooth extraction makes it technique-sensitive and limits its use. This case report presents a 29-year-old medically fit male patient with a destructed non-vital lateral incisor. It was planned for immediate implant placement in conjunction with the socket-shield technique. The shield was prepared in a new technique using a nickel–titanium endodontic file, which was repeatedly adjusted to increase the diameter of the canal gradually. The canal was enlarged to reach a sufficient diameter to perform root separation safely. Following the shield preparation, immediate implant placement was preformed, and screw-retained temporary crown was done. Oxford University Press 2023-08-14 /pmc/articles/PMC10431202/ /pubmed/37593187 http://dx.doi.org/10.1093/jscr/rjad464 Text en Published by Oxford University Press and JSCR Publishing Ltd. © The Author(s) 2023. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Lahham, Cezar Lahham, Elias Edward Ali, Ali Abu A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title | A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title_full | A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title_fullStr | A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title_full_unstemmed | A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title_short | A novel technique for socket-shield preparation used in conjunction with immediate implant placement. A case report |
title_sort | novel technique for socket-shield preparation used in conjunction with immediate implant placement. a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10431202/ https://www.ncbi.nlm.nih.gov/pubmed/37593187 http://dx.doi.org/10.1093/jscr/rjad464 |
work_keys_str_mv | AT lahhamcezar anoveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport AT lahhameliasedward anoveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport AT alialiabu anoveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport AT lahhamcezar noveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport AT lahhameliasedward noveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport AT alialiabu noveltechniqueforsocketshieldpreparationusedinconjunctionwithimmediateimplantplacementacasereport |