Cargando…

Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation

OBJECTIVE: The purpose of this study was to examine the feasibility of using augmented reality during lead placement for sacral nerve stimulation (SNS). METHODS: The study was a prospective case series performed in a single tertiary center. Patients with fecal incontinence or urinary retention eligi...

Descripción completa

Detalles Bibliográficos
Autores principales: Freidin, Dor, Zilka, Nadav, Horesh, Nir, Saukhat, Olga, Ram, Edward, Tejman-Yarden, Shai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10431399/
https://www.ncbi.nlm.nih.gov/pubmed/37600095
http://dx.doi.org/10.1097/AS9.0000000000000138
_version_ 1785091191724834816
author Freidin, Dor
Zilka, Nadav
Horesh, Nir
Saukhat, Olga
Ram, Edward
Tejman-Yarden, Shai
author_facet Freidin, Dor
Zilka, Nadav
Horesh, Nir
Saukhat, Olga
Ram, Edward
Tejman-Yarden, Shai
author_sort Freidin, Dor
collection PubMed
description OBJECTIVE: The purpose of this study was to examine the feasibility of using augmented reality during lead placement for sacral nerve stimulation (SNS). METHODS: The study was a prospective case series performed in a single tertiary center. Patients with fecal incontinence or urinary retention eligible for SNS according to the American society of colon and rectal surgeon’s guidelines were included. Each patient underwent a computerized tomography scan of the sacrum and pelvic floor before surgery; and a segmentation of the sacral bone, the skin, and three fiducial markers on the lower back was produced. Surgical planning included the design of an ideal virtual transmission tract leading to the S3 foramen using the most suitable location and needle trajectory for introducing the lead. During the surgical intervention, a needle was inserted into the S3 foramen using the aligned tract as visualized using the Microsoft HoloLens first generation head mounted unit. RESULTS: Overall, 11 patients were included. Mean operative time was 43.8 minutes (range 25–81 minutes). All patients reported a significant reduction from the preoperative level of the mean postoperative Cleveland Clinic Incontinence Score (CCIS) assessed 2 weeks after the temporary SNS implant (CCIS preoperative 13.3, postoperative 8.5; CI –7.35 to –2.25; P < 0.01). The surgeons reported the imaging useful, allowing accurate and easier approach. CONCLUSIONS: Intraoperative augmented reality imaging for needle application during SNS appears to be feasible, practical, and may be useful in additional procedures.
format Online
Article
Text
id pubmed-10431399
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer Health, Inc.
record_format MEDLINE/PubMed
spelling pubmed-104313992023-08-18 Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation Freidin, Dor Zilka, Nadav Horesh, Nir Saukhat, Olga Ram, Edward Tejman-Yarden, Shai Ann Surg Open Brief Clinical Report OBJECTIVE: The purpose of this study was to examine the feasibility of using augmented reality during lead placement for sacral nerve stimulation (SNS). METHODS: The study was a prospective case series performed in a single tertiary center. Patients with fecal incontinence or urinary retention eligible for SNS according to the American society of colon and rectal surgeon’s guidelines were included. Each patient underwent a computerized tomography scan of the sacrum and pelvic floor before surgery; and a segmentation of the sacral bone, the skin, and three fiducial markers on the lower back was produced. Surgical planning included the design of an ideal virtual transmission tract leading to the S3 foramen using the most suitable location and needle trajectory for introducing the lead. During the surgical intervention, a needle was inserted into the S3 foramen using the aligned tract as visualized using the Microsoft HoloLens first generation head mounted unit. RESULTS: Overall, 11 patients were included. Mean operative time was 43.8 minutes (range 25–81 minutes). All patients reported a significant reduction from the preoperative level of the mean postoperative Cleveland Clinic Incontinence Score (CCIS) assessed 2 weeks after the temporary SNS implant (CCIS preoperative 13.3, postoperative 8.5; CI –7.35 to –2.25; P < 0.01). The surgeons reported the imaging useful, allowing accurate and easier approach. CONCLUSIONS: Intraoperative augmented reality imaging for needle application during SNS appears to be feasible, practical, and may be useful in additional procedures. Wolters Kluwer Health, Inc. 2022-02-23 /pmc/articles/PMC10431399/ /pubmed/37600095 http://dx.doi.org/10.1097/AS9.0000000000000138 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Brief Clinical Report
Freidin, Dor
Zilka, Nadav
Horesh, Nir
Saukhat, Olga
Ram, Edward
Tejman-Yarden, Shai
Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title_full Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title_fullStr Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title_full_unstemmed Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title_short Using Augmented Reality for Intraoperative Guidance During Sacral Neuromodulation System Implantation
title_sort using augmented reality for intraoperative guidance during sacral neuromodulation system implantation
topic Brief Clinical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10431399/
https://www.ncbi.nlm.nih.gov/pubmed/37600095
http://dx.doi.org/10.1097/AS9.0000000000000138
work_keys_str_mv AT freidindor usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation
AT zilkanadav usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation
AT horeshnir usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation
AT saukhatolga usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation
AT ramedward usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation
AT tejmanyardenshai usingaugmentedrealityforintraoperativeguidanceduringsacralneuromodulationsystemimplantation