Cargando…
Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study
PURPOSE: To determine whether patients with type 1 diabetes mellitus (T1DM), without any sign of diabetic retinopathy, have any alteration in Contrast Sensitivity Function (CSF), in relation to patients without this disease, and whether CSF assessment in three different light conditions can be an ef...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10432366/ https://www.ncbi.nlm.nih.gov/pubmed/37039937 http://dx.doi.org/10.1007/s00417-023-06057-6 |
_version_ | 1785091388248948736 |
---|---|
author | Silva-Viguera, María-Carmen García-Romera, Marta C. Bautista-Llamas, María-José |
author_facet | Silva-Viguera, María-Carmen García-Romera, Marta C. Bautista-Llamas, María-José |
author_sort | Silva-Viguera, María-Carmen |
collection | PubMed |
description | PURPOSE: To determine whether patients with type 1 diabetes mellitus (T1DM), without any sign of diabetic retinopathy, have any alteration in Contrast Sensitivity Function (CSF), in relation to patients without this disease, and whether CSF assessment in three different light conditions can be an effective test in the early detection of diabetic retinopathy. METHODS: A prospective, cross-sectional, case-control study was preformed including 80 patients (40 with T1DM without diabetic retinopathy and 40 controls) between 11 and 47 years old. CSF was assessed at four spatial frequencies (3, 6, 12 and 18 cycles/degree) using the CSV-1000E test, under three light conditions: high (550 lx), medium (200 lx) and low (< 2 lx). RESULTS: A lower CSF in the T1DM group was found at the three light conditions studied. The most spatial frequency affected was 18 cpd, 0.08 log units (p = 0.048) in high, 0.10 log units (p = 0.010) in medium (p = 0.010) and 0.16 log units (p < 0.001) in low-light conditions in mean CS values. The least spatial frequency affected was 3 cpd (p > 0.05 in all three light conditions). CONCLUSION: Patients with T1DM, without diabetic retinopathy, presented a loss of CS to sine-wave gratings, with respect to people with the same characteristics without the disease, mainly at medium and high frequencies, and in medium and low-light conditions. |
format | Online Article Text |
id | pubmed-10432366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-104323662023-08-18 Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study Silva-Viguera, María-Carmen García-Romera, Marta C. Bautista-Llamas, María-José Graefes Arch Clin Exp Ophthalmol Retinal Disorders PURPOSE: To determine whether patients with type 1 diabetes mellitus (T1DM), without any sign of diabetic retinopathy, have any alteration in Contrast Sensitivity Function (CSF), in relation to patients without this disease, and whether CSF assessment in three different light conditions can be an effective test in the early detection of diabetic retinopathy. METHODS: A prospective, cross-sectional, case-control study was preformed including 80 patients (40 with T1DM without diabetic retinopathy and 40 controls) between 11 and 47 years old. CSF was assessed at four spatial frequencies (3, 6, 12 and 18 cycles/degree) using the CSV-1000E test, under three light conditions: high (550 lx), medium (200 lx) and low (< 2 lx). RESULTS: A lower CSF in the T1DM group was found at the three light conditions studied. The most spatial frequency affected was 18 cpd, 0.08 log units (p = 0.048) in high, 0.10 log units (p = 0.010) in medium (p = 0.010) and 0.16 log units (p < 0.001) in low-light conditions in mean CS values. The least spatial frequency affected was 3 cpd (p > 0.05 in all three light conditions). CONCLUSION: Patients with T1DM, without diabetic retinopathy, presented a loss of CS to sine-wave gratings, with respect to people with the same characteristics without the disease, mainly at medium and high frequencies, and in medium and low-light conditions. Springer Berlin Heidelberg 2023-04-11 2023 /pmc/articles/PMC10432366/ /pubmed/37039937 http://dx.doi.org/10.1007/s00417-023-06057-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Retinal Disorders Silva-Viguera, María-Carmen García-Romera, Marta C. Bautista-Llamas, María-José Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title | Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title_full | Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title_fullStr | Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title_full_unstemmed | Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title_short | Contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
title_sort | contrast sensitivity function under three light conditions in patients with type 1 diabetes mellitus without retinopathy: a cross-sectional, case–control study |
topic | Retinal Disorders |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10432366/ https://www.ncbi.nlm.nih.gov/pubmed/37039937 http://dx.doi.org/10.1007/s00417-023-06057-6 |
work_keys_str_mv | AT silvavigueramariacarmen contrastsensitivityfunctionunderthreelightconditionsinpatientswithtype1diabetesmellituswithoutretinopathyacrosssectionalcasecontrolstudy AT garciaromeramartac contrastsensitivityfunctionunderthreelightconditionsinpatientswithtype1diabetesmellituswithoutretinopathyacrosssectionalcasecontrolstudy AT bautistallamasmariajose contrastsensitivityfunctionunderthreelightconditionsinpatientswithtype1diabetesmellituswithoutretinopathyacrosssectionalcasecontrolstudy |