Cargando…

Risk Factors and Outcome of Pulmonary Artery Stenting After Bidirectional Cavopulmonary Connection (BDCPC) in Single Ventricle Circulation

After bidirectional cavopulmonary connection (BDCPC) central pulmonary arteries (PAs) of single ventricle (SV) patients can be affected by stenosis or even closure. Aim of this study is to compare SV patients with and without PA-stent implantation post-BDCPC regarding risk factors for stent implanta...

Descripción completa

Detalles Bibliográficos
Autores principales: Callegari, Alessia, Logoteta, Jana, Knirsch, Walter, Cesnjevar, Robert, Dave, Hitendu, Kretschmar, Oliver, Quandt, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435611/
https://www.ncbi.nlm.nih.gov/pubmed/37453932
http://dx.doi.org/10.1007/s00246-023-03229-3
Descripción
Sumario:After bidirectional cavopulmonary connection (BDCPC) central pulmonary arteries (PAs) of single ventricle (SV) patients can be affected by stenosis or even closure. Aim of this study is to compare SV patients with and without PA-stent implantation post-BDCPC regarding risk factors for stent implantation and outcome. Single center, retrospective (2006–2021) study of 136 SV consecutive patients with and without PA-stent implantation post-BDCPC. Patient characteristics, risk factors for PA-stent implantation and PA growth were assessed comparing angiographic data pre-BDCPC and pre-TCPC. A total of 40/136 (29%) patients underwent PA-stent implantation at median (IQR) 14 (1.1–39.0) days post-BDCPC. 37/40 (92.5%) underwent LPA-stenting. Multiple regression analysis showed single LV patients to receive less likely PA-stents than single RV patients (OR 0.41; p = 0.05). Reduced LPA/BSA (mm/m2) and larger diameter of neo-ascending aorta pre-BDCPC were associated with an increased likelihood of PA-stent implantation post-BDCPC (OR 0.89, p = 0.03; OR 1.05, p = 0.001). Stent re-dilatation was performed in 36/40 (89%) after 1 (0.8–1.5) year. Pulmonary artery diameters pre-BDCPC were lower in the PA-stent group: McGoon (p < 0.001), Nakata (p < 0.001). Indexed pulmonary artery diameters increased equally in both groups but remained lower pre-TCPC in the PA-stent group: McGoon (p < 0.001), Nakata (p = 0.009), and Lower Lobe Index (p = 0.003). LPA and RPA grew symmetrically in both groups. Single RV, larger neo-ascending aorta, and small LPA pre- BDCPC are independent risk factors for PA-stent implantation post-BDCPC. Pulmonary artery diameters after PA-stent implantation and stent re-dilatation showed significant growth together with the contralateral side, but the PA-system remained symmetrically smaller in the stent group.