Intraoperative electromyographic monitoring in children using a novel pediatric sensor

BACKGROUND: Train-of-four (TOF) monitoring is essential in optimizing perioperative outcomes as a means to assess the depth of neuromuscular blockade and confirm recovery following the administration of neuromuscular blocking agents (NMBAs). Quantitative TOF monitoring has been limited in infants an...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalsotra, Sidhant, Rice-Weimer, Julie, Tobias, Joseph D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435795/
https://www.ncbi.nlm.nih.gov/pubmed/37601498
http://dx.doi.org/10.4103/sja.sja_160_23
_version_ 1785092184116035584
author Kalsotra, Sidhant
Rice-Weimer, Julie
Tobias, Joseph D.
author_facet Kalsotra, Sidhant
Rice-Weimer, Julie
Tobias, Joseph D.
author_sort Kalsotra, Sidhant
collection PubMed
description BACKGROUND: Train-of-four (TOF) monitoring is essential in optimizing perioperative outcomes as a means to assess the depth of neuromuscular blockade and confirm recovery following the administration of neuromuscular blocking agents (NMBAs). Quantitative TOF monitoring has been limited in infants and children primarily due to lack of effective equipment. The current study evaluates a novel electromyography (EMG)-based TOF monitor with a recently developed pediatric-sized self-adhesive sensor in infants and children. METHODS: Consented pediatric patients undergoing inpatient surgery requiring the administration of NMBAs were enrolled. The EMG electrode was placed along the ulnar nerve on the volar aspect of the distal forearm. The muscle action potentials from the adductor pollicis muscle were recorded throughout surgery at 20-second intervals. Data from the monitor’s built-in memory card were later retrieved and analyzed. RESULTS: The final study cohort included 51 patients who ranged in age from 0.2 to 7.9 years and in weight from 4.2 to 36.0 kilograms. Thirty patients weighed less than 15 kgs. Supramaximal stimulus current intensity (mA) at a pulse width of 200 μsec was 30 mA in 8%; 40 mA in 29%; 50 mA in 16%; and 60 mA in 20% of the patients. Supramaximal stimulus current intensity (mA) at a pulse width of 300 μsec was 50 mA in 4%; 60 mA in 24%. The muscle action potential baseline amplitude was 8.7 ± 3.3 mV and recovered to 7.2 ± 3.7 mV after antagonism of neuromuscular blockade. The average baseline TOF ratio was 100 ± 3% and recovered to 98 ± 7% after antagonism of neuromuscular blockade. No technical issues were noted with application of the sensor or subsequent use of the monitor. CONCLUSION: Neuromuscular monitoring can be performed intraoperatively in pediatric patients who are less than 8 years of age using a novel commercially available EMG-based monitor with a recently developed pediatric sensor. The novel sensor allows use of an EMG-based monitor in infants and children in whom acceleromyography or subjective (visual) observation of the TOF response may not be feasible. Automatic detection of neuromuscular stimulating parameters (supramaximal current intensity level, baseline amplitude of the muscle action potential) was feasible in pediatric patients of all sizes including those weighing less than 15 kilograms or when there was limited access to the extremity being monitored.
format Online
Article
Text
id pubmed-10435795
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104357952023-08-19 Intraoperative electromyographic monitoring in children using a novel pediatric sensor Kalsotra, Sidhant Rice-Weimer, Julie Tobias, Joseph D. Saudi J Anaesth Original Article BACKGROUND: Train-of-four (TOF) monitoring is essential in optimizing perioperative outcomes as a means to assess the depth of neuromuscular blockade and confirm recovery following the administration of neuromuscular blocking agents (NMBAs). Quantitative TOF monitoring has been limited in infants and children primarily due to lack of effective equipment. The current study evaluates a novel electromyography (EMG)-based TOF monitor with a recently developed pediatric-sized self-adhesive sensor in infants and children. METHODS: Consented pediatric patients undergoing inpatient surgery requiring the administration of NMBAs were enrolled. The EMG electrode was placed along the ulnar nerve on the volar aspect of the distal forearm. The muscle action potentials from the adductor pollicis muscle were recorded throughout surgery at 20-second intervals. Data from the monitor’s built-in memory card were later retrieved and analyzed. RESULTS: The final study cohort included 51 patients who ranged in age from 0.2 to 7.9 years and in weight from 4.2 to 36.0 kilograms. Thirty patients weighed less than 15 kgs. Supramaximal stimulus current intensity (mA) at a pulse width of 200 μsec was 30 mA in 8%; 40 mA in 29%; 50 mA in 16%; and 60 mA in 20% of the patients. Supramaximal stimulus current intensity (mA) at a pulse width of 300 μsec was 50 mA in 4%; 60 mA in 24%. The muscle action potential baseline amplitude was 8.7 ± 3.3 mV and recovered to 7.2 ± 3.7 mV after antagonism of neuromuscular blockade. The average baseline TOF ratio was 100 ± 3% and recovered to 98 ± 7% after antagonism of neuromuscular blockade. No technical issues were noted with application of the sensor or subsequent use of the monitor. CONCLUSION: Neuromuscular monitoring can be performed intraoperatively in pediatric patients who are less than 8 years of age using a novel commercially available EMG-based monitor with a recently developed pediatric sensor. The novel sensor allows use of an EMG-based monitor in infants and children in whom acceleromyography or subjective (visual) observation of the TOF response may not be feasible. Automatic detection of neuromuscular stimulating parameters (supramaximal current intensity level, baseline amplitude of the muscle action potential) was feasible in pediatric patients of all sizes including those weighing less than 15 kilograms or when there was limited access to the extremity being monitored. Wolters Kluwer - Medknow 2023 2023-06-22 /pmc/articles/PMC10435795/ /pubmed/37601498 http://dx.doi.org/10.4103/sja.sja_160_23 Text en Copyright: © 2023 Saudi Journal of Anesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kalsotra, Sidhant
Rice-Weimer, Julie
Tobias, Joseph D.
Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title_full Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title_fullStr Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title_full_unstemmed Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title_short Intraoperative electromyographic monitoring in children using a novel pediatric sensor
title_sort intraoperative electromyographic monitoring in children using a novel pediatric sensor
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435795/
https://www.ncbi.nlm.nih.gov/pubmed/37601498
http://dx.doi.org/10.4103/sja.sja_160_23
work_keys_str_mv AT kalsotrasidhant intraoperativeelectromyographicmonitoringinchildrenusinganovelpediatricsensor
AT riceweimerjulie intraoperativeelectromyographicmonitoringinchildrenusinganovelpediatricsensor
AT tobiasjosephd intraoperativeelectromyographicmonitoringinchildrenusinganovelpediatricsensor