Cargando…
Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study
BACKGROUND: CommandEP™ is a mixed reality (MXR) system for cardiac electrophysiological (EP) procedures that provides a real-time 3-dimensional digital image of cardiac geometry and catheter locations. In a previous study, physicians using the system demonstrated improved navigational accuracy. This...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435945/ https://www.ncbi.nlm.nih.gov/pubmed/37600447 http://dx.doi.org/10.1016/j.cvdhj.2023.06.003 |
_version_ | 1785092218479968256 |
---|---|
author | Bloom, David Catherall, David Miller, Nathan Southworth, Michael K. Glatz, Andrew C. Silva, Jonathan R. Avari Silva, Jennifer N. |
author_facet | Bloom, David Catherall, David Miller, Nathan Southworth, Michael K. Glatz, Andrew C. Silva, Jonathan R. Avari Silva, Jennifer N. |
author_sort | Bloom, David |
collection | PubMed |
description | BACKGROUND: CommandEP™ is a mixed reality (MXR) system for cardiac electrophysiological (EP) procedures that provides a real-time 3-dimensional digital image of cardiac geometry and catheter locations. In a previous study, physicians using the system demonstrated improved navigational accuracy. This study investigated the impact of the CommandEP system on EP procedural times compared to the standard-of-care electroanatomic mapping system (EAMS) display. OBJECTIVE: The purpose of this retrospective case-controlled analysis was to evaluate the impact of a novel MXR interface on EP procedural times compared to a case-matched cohort. METHODS: Cases from the Cardiac Augmented REality (CARE) study were matched for diagnosis and weight using a contemporary cohort. Procedural time was compared from the roll-in and full implementation cohort. During routine EP procedures, operators performed tasks during the postablation waiting phase, including creation of cardiac geometry and 5-point navigation under 2 conditions: (1) EAMS first; and (2) CommandEP. RESULTS: From a total of 16 CARE study patients, the 10 full implementation patients were matched to a cohort of 20 control patients (2 controls:1 CARE, matched according to pathology and age/weight). No statistical difference in total case times between CARE study patients vs control group (118 ± 29 minutes vs 97 ± 20 minutes; P = .07) or fluoroscopy times (6 ± 4 minutes vs 7 ± 6 minutes; P = .9). No significant difference in case duration for CARE study patients comparing roll-in vs full-implementation cohort (121 ± 26 minutes vs 118 ± 29 minutes; P = .96). CommandEP wear time during cases was significantly longer in full implementation cases (53 ± 24 minutes vs 24 ± 5 minutes; P = .0009). During creation of a single cardiac geometry, no significant time difference was noted between CommandEP vs EAMS (284 ± 45 seconds vs 268 ± 43 seconds; P = .1) or fluoroscopy use (9 ± 19 seconds vs 6 ± 18 seconds; P = .25). During point navigation tasks, there was no difference in total time (CommandEP 31 ± 14 seconds vs EAMS 28 ± 15 seconds; P = .16) or fluoroscopy time (CommandEP 0 second vs EAMS 0 second). CONCLUSION: MXR did not prolong overall procedural time compared to a matched cohort. There was no prolongation in study task completion time. Future studies with experienced CommandEP users directly assessing procedural time and task completion time in a randomized study population would be of interest. |
format | Online Article Text |
id | pubmed-10435945 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104359452023-08-19 Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study Bloom, David Catherall, David Miller, Nathan Southworth, Michael K. Glatz, Andrew C. Silva, Jonathan R. Avari Silva, Jennifer N. Cardiovasc Digit Health J Original Article BACKGROUND: CommandEP™ is a mixed reality (MXR) system for cardiac electrophysiological (EP) procedures that provides a real-time 3-dimensional digital image of cardiac geometry and catheter locations. In a previous study, physicians using the system demonstrated improved navigational accuracy. This study investigated the impact of the CommandEP system on EP procedural times compared to the standard-of-care electroanatomic mapping system (EAMS) display. OBJECTIVE: The purpose of this retrospective case-controlled analysis was to evaluate the impact of a novel MXR interface on EP procedural times compared to a case-matched cohort. METHODS: Cases from the Cardiac Augmented REality (CARE) study were matched for diagnosis and weight using a contemporary cohort. Procedural time was compared from the roll-in and full implementation cohort. During routine EP procedures, operators performed tasks during the postablation waiting phase, including creation of cardiac geometry and 5-point navigation under 2 conditions: (1) EAMS first; and (2) CommandEP. RESULTS: From a total of 16 CARE study patients, the 10 full implementation patients were matched to a cohort of 20 control patients (2 controls:1 CARE, matched according to pathology and age/weight). No statistical difference in total case times between CARE study patients vs control group (118 ± 29 minutes vs 97 ± 20 minutes; P = .07) or fluoroscopy times (6 ± 4 minutes vs 7 ± 6 minutes; P = .9). No significant difference in case duration for CARE study patients comparing roll-in vs full-implementation cohort (121 ± 26 minutes vs 118 ± 29 minutes; P = .96). CommandEP wear time during cases was significantly longer in full implementation cases (53 ± 24 minutes vs 24 ± 5 minutes; P = .0009). During creation of a single cardiac geometry, no significant time difference was noted between CommandEP vs EAMS (284 ± 45 seconds vs 268 ± 43 seconds; P = .1) or fluoroscopy use (9 ± 19 seconds vs 6 ± 18 seconds; P = .25). During point navigation tasks, there was no difference in total time (CommandEP 31 ± 14 seconds vs EAMS 28 ± 15 seconds; P = .16) or fluoroscopy time (CommandEP 0 second vs EAMS 0 second). CONCLUSION: MXR did not prolong overall procedural time compared to a matched cohort. There was no prolongation in study task completion time. Future studies with experienced CommandEP users directly assessing procedural time and task completion time in a randomized study population would be of interest. Elsevier 2023-06-14 /pmc/articles/PMC10435945/ /pubmed/37600447 http://dx.doi.org/10.1016/j.cvdhj.2023.06.003 Text en © 2023 Published by Elsevier Inc. on behalf of Heart Rhythm Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Bloom, David Catherall, David Miller, Nathan Southworth, Michael K. Glatz, Andrew C. Silva, Jonathan R. Avari Silva, Jennifer N. Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title | Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title_full | Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title_fullStr | Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title_full_unstemmed | Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title_short | Use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: A subanalysis from the Cardiac Augmented REality study |
title_sort | use of a mixed reality system for navigational mapping during cardiac electrophysiological testing does not prolong case duration: a subanalysis from the cardiac augmented reality study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435945/ https://www.ncbi.nlm.nih.gov/pubmed/37600447 http://dx.doi.org/10.1016/j.cvdhj.2023.06.003 |
work_keys_str_mv | AT bloomdavid useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT catheralldavid useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT millernathan useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT southworthmichaelk useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT glatzandrewc useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT silvajonathanr useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy AT avarisilvajennifern useofamixedrealitysystemfornavigationalmappingduringcardiacelectrophysiologicaltestingdoesnotprolongcasedurationasubanalysisfromthecardiacaugmentedrealitystudy |