Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study

BACKGROUND: Mobility is a meaningful aspect of an individual’s health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. OBJECTIVE: Our objective was to characterize the analy...

Descripción completa

Detalles Bibliográficos
Autores principales: Kowahl, Nathan, Shin, Sooyoon, Barman, Poulami, Rainaldi, Erin, Popham, Sara, Kapur, Ritu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10436116/
https://www.ncbi.nlm.nih.gov/pubmed/37535417
http://dx.doi.org/10.2196/48270
_version_ 1785092255875334144
author Kowahl, Nathan
Shin, Sooyoon
Barman, Poulami
Rainaldi, Erin
Popham, Sara
Kapur, Ritu
author_facet Kowahl, Nathan
Shin, Sooyoon
Barman, Poulami
Rainaldi, Erin
Popham, Sara
Kapur, Ritu
author_sort Kowahl, Nathan
collection PubMed
description BACKGROUND: Mobility is a meaningful aspect of an individual’s health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. OBJECTIVE: Our objective was to characterize the analytical performance (accuracy and reliability) of a suite of digital measures of walking behaviors as critical aspects in the practical implementation of digital measures into clinical studies. METHODS: We collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without a history of gait or walking impairment in a real-world setting. On the basis of step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, and peak 30-minute walking pace. To characterize the accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4) with known low error, calculating the following metrics: intraclass correlation coefficient (ICC), Pearson r coefficient, mean error, and mean absolute error. To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time to reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1 to 30 days and analyzing test-retest reliability based on ICCs between adjacent (nonoverlapping) time windows for each measure. RESULTS: In the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (n=35 participants; median observation time 5 days). Agreement with the reference device–based readouts in the testing subcohort (n=35) for the 8 measurements under evaluation, as reflected by ICCs, ranged between 0.7 and 0.9; Pearson r values were all greater than 0.75, and all reached statistical significance (P<.001). For the time-to-reliability characterization, we collected data for a total of 15,120 participant-days (overall cohort N=234; median observation time 119 days). All digital measures achieved an ICC between adjacent readouts of >0.75 by 16 days of wear time. CONCLUSIONS: We characterized the accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide the practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions.
format Online
Article
Text
id pubmed-10436116
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-104361162023-08-19 Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study Kowahl, Nathan Shin, Sooyoon Barman, Poulami Rainaldi, Erin Popham, Sara Kapur, Ritu JMIR Hum Factors Original Paper BACKGROUND: Mobility is a meaningful aspect of an individual’s health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. OBJECTIVE: Our objective was to characterize the analytical performance (accuracy and reliability) of a suite of digital measures of walking behaviors as critical aspects in the practical implementation of digital measures into clinical studies. METHODS: We collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without a history of gait or walking impairment in a real-world setting. On the basis of step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, and peak 30-minute walking pace. To characterize the accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4) with known low error, calculating the following metrics: intraclass correlation coefficient (ICC), Pearson r coefficient, mean error, and mean absolute error. To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time to reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1 to 30 days and analyzing test-retest reliability based on ICCs between adjacent (nonoverlapping) time windows for each measure. RESULTS: In the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (n=35 participants; median observation time 5 days). Agreement with the reference device–based readouts in the testing subcohort (n=35) for the 8 measurements under evaluation, as reflected by ICCs, ranged between 0.7 and 0.9; Pearson r values were all greater than 0.75, and all reached statistical significance (P<.001). For the time-to-reliability characterization, we collected data for a total of 15,120 participant-days (overall cohort N=234; median observation time 119 days). All digital measures achieved an ICC between adjacent readouts of >0.75 by 16 days of wear time. CONCLUSIONS: We characterized the accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide the practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions. JMIR Publications 2023-08-03 /pmc/articles/PMC10436116/ /pubmed/37535417 http://dx.doi.org/10.2196/48270 Text en ©Nathan Kowahl, Sooyoon Shin, Poulami Barman, Erin Rainaldi, Sara Popham, Ritu Kapur. Originally published in JMIR Human Factors (https://humanfactors.jmir.org), 03.08.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Human Factors, is properly cited. The complete bibliographic information, a link to the original publication on https://humanfactors.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Kowahl, Nathan
Shin, Sooyoon
Barman, Poulami
Rainaldi, Erin
Popham, Sara
Kapur, Ritu
Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title_full Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title_fullStr Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title_full_unstemmed Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title_short Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study
title_sort accuracy and reliability of a suite of digital measures of walking generated using a wrist-worn sensor in healthy individuals: performance characterization study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10436116/
https://www.ncbi.nlm.nih.gov/pubmed/37535417
http://dx.doi.org/10.2196/48270
work_keys_str_mv AT kowahlnathan accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy
AT shinsooyoon accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy
AT barmanpoulami accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy
AT rainaldierin accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy
AT pophamsara accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy
AT kapurritu accuracyandreliabilityofasuiteofdigitalmeasuresofwalkinggeneratedusingawristwornsensorinhealthyindividualsperformancecharacterizationstudy