Cargando…

Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula

BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in compa...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Ateah, Ghazi, Kirschfink, Annemarie, Frick, Michael, Almalla, Mohammad, Becker, Michael, Cornelissen, Christian, Hoffmann, Rainer, Marx, Nikolaus, Altiok, Ertunc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10437865/
https://www.ncbi.nlm.nih.gov/pubmed/37594956
http://dx.doi.org/10.1371/journal.pone.0290418
_version_ 1785092633850281984
author Al Ateah, Ghazi
Kirschfink, Annemarie
Frick, Michael
Almalla, Mohammad
Becker, Michael
Cornelissen, Christian
Hoffmann, Rainer
Marx, Nikolaus
Altiok, Ertunc
author_facet Al Ateah, Ghazi
Kirschfink, Annemarie
Frick, Michael
Almalla, Mohammad
Becker, Michael
Cornelissen, Christian
Hoffmann, Rainer
Marx, Nikolaus
Altiok, Ertunc
author_sort Al Ateah, Ghazi
collection PubMed
description BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). METHODS: 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd(2) * Ld, and RV ESV = 1.21 * Ds(2) * Ls. RESULTS: Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). CONCLUSION: Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC.
format Online
Article
Text
id pubmed-10437865
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-104378652023-08-19 Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula Al Ateah, Ghazi Kirschfink, Annemarie Frick, Michael Almalla, Mohammad Becker, Michael Cornelissen, Christian Hoffmann, Rainer Marx, Nikolaus Altiok, Ertunc PLoS One Research Article BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). METHODS: 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd(2) * Ld, and RV ESV = 1.21 * Ds(2) * Ls. RESULTS: Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). CONCLUSION: Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC. Public Library of Science 2023-08-18 /pmc/articles/PMC10437865/ /pubmed/37594956 http://dx.doi.org/10.1371/journal.pone.0290418 Text en © 2023 Al Ateah et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Al Ateah, Ghazi
Kirschfink, Annemarie
Frick, Michael
Almalla, Mohammad
Becker, Michael
Cornelissen, Christian
Hoffmann, Rainer
Marx, Nikolaus
Altiok, Ertunc
Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title_full Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title_fullStr Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title_full_unstemmed Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title_short Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
title_sort echocardiographic determination of right ventricular volumes and ejection fraction: validation of a truncated cone and rhomboid pyramid formula
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10437865/
https://www.ncbi.nlm.nih.gov/pubmed/37594956
http://dx.doi.org/10.1371/journal.pone.0290418
work_keys_str_mv AT alateahghazi echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT kirschfinkannemarie echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT frickmichael echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT almallamohammad echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT beckermichael echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT cornelissenchristian echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT hoffmannrainer echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT marxnikolaus echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula
AT altiokertunc echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula