Cargando…
Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula
BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in compa...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10437865/ https://www.ncbi.nlm.nih.gov/pubmed/37594956 http://dx.doi.org/10.1371/journal.pone.0290418 |
_version_ | 1785092633850281984 |
---|---|
author | Al Ateah, Ghazi Kirschfink, Annemarie Frick, Michael Almalla, Mohammad Becker, Michael Cornelissen, Christian Hoffmann, Rainer Marx, Nikolaus Altiok, Ertunc |
author_facet | Al Ateah, Ghazi Kirschfink, Annemarie Frick, Michael Almalla, Mohammad Becker, Michael Cornelissen, Christian Hoffmann, Rainer Marx, Nikolaus Altiok, Ertunc |
author_sort | Al Ateah, Ghazi |
collection | PubMed |
description | BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). METHODS: 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd(2) * Ld, and RV ESV = 1.21 * Ds(2) * Ls. RESULTS: Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). CONCLUSION: Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC. |
format | Online Article Text |
id | pubmed-10437865 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-104378652023-08-19 Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula Al Ateah, Ghazi Kirschfink, Annemarie Frick, Michael Almalla, Mohammad Becker, Michael Cornelissen, Christian Hoffmann, Rainer Marx, Nikolaus Altiok, Ertunc PLoS One Research Article BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). METHODS: 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd(2) * Ld, and RV ESV = 1.21 * Ds(2) * Ls. RESULTS: Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). CONCLUSION: Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC. Public Library of Science 2023-08-18 /pmc/articles/PMC10437865/ /pubmed/37594956 http://dx.doi.org/10.1371/journal.pone.0290418 Text en © 2023 Al Ateah et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Al Ateah, Ghazi Kirschfink, Annemarie Frick, Michael Almalla, Mohammad Becker, Michael Cornelissen, Christian Hoffmann, Rainer Marx, Nikolaus Altiok, Ertunc Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title | Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title_full | Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title_fullStr | Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title_full_unstemmed | Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title_short | Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula |
title_sort | echocardiographic determination of right ventricular volumes and ejection fraction: validation of a truncated cone and rhomboid pyramid formula |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10437865/ https://www.ncbi.nlm.nih.gov/pubmed/37594956 http://dx.doi.org/10.1371/journal.pone.0290418 |
work_keys_str_mv | AT alateahghazi echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT kirschfinkannemarie echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT frickmichael echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT almallamohammad echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT beckermichael echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT cornelissenchristian echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT hoffmannrainer echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT marxnikolaus echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula AT altiokertunc echocardiographicdeterminationofrightventricularvolumesandejectionfractionvalidationofatruncatedconeandrhomboidpyramidformula |