Cargando…

Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates

BACKGROUND & OBJECTIVES: Postpartum intrauterine contraceptive device (PPIUCD) is well accepted and recommended for contraception. However, anxiety at the time of delivery may restrict the acceptance of a PPIUCD for its immediate insertion. So far there is limited evidence to conclude anything c...

Descripción completa

Detalles Bibliográficos
Autores principales: Dorairajan, Gowri, Ashok, Venkatesh M., Veena, P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438408/
https://www.ncbi.nlm.nih.gov/pubmed/37282395
http://dx.doi.org/10.4103/ijmr.IJMR_1485_19
_version_ 1785092784184623104
author Dorairajan, Gowri
Ashok, Venkatesh M.
Veena, P.
author_facet Dorairajan, Gowri
Ashok, Venkatesh M.
Veena, P.
author_sort Dorairajan, Gowri
collection PubMed
description BACKGROUND & OBJECTIVES: Postpartum intrauterine contraceptive device (PPIUCD) is well accepted and recommended for contraception. However, anxiety at the time of delivery may restrict the acceptance of a PPIUCD for its immediate insertion. So far there is limited evidence to conclude anything concrete on the association between the expulsion rates and the timing of insertion following a vaginal delivery. Thus, this study was undertaken to compare the expulsion rates in immediate and early insertions and their safety and complications. METHODS: This prospective comparative study was carried out over 17 months on women delivering vaginally in a tertiary care teaching hospital in South India. A copper device (CuT380A) was inserted using Kelly’s placental forceps either within 10 min of placental delivery (immediate group, n=160) or between 10 min upto 48 h postpartum (early group, n=160). Ultrasound was done before discharge from the hospital. The expulsion rates and any other complications at six-week and three-month follow up were studied. Chi-square test was used to compare the difference in expulsion rates. RESULTS: The expulsion rate was five per cent in the immediate compared to 3.7 per cent in the early group (no significant difference). In ten cases, the device was found to be in the lower uterus upon ultrasound before discharge. These were repositioned. There was no case with perforation, irregular bleeding or infection up to the three-month follow up. Higher age, higher parity, lack of satisfaction and motivation to continue were predictors of expulsion. INTERPRETATION & CONCLUSIONS: In the present study PPIUCD was found to be safe with overall expulsion in 4.3 per cent. It was marginally, though not significantly, higher in the immediate group.
format Online
Article
Text
id pubmed-10438408
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104384082023-08-19 Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates Dorairajan, Gowri Ashok, Venkatesh M. Veena, P. Indian J Med Res Practice: Original Article BACKGROUND & OBJECTIVES: Postpartum intrauterine contraceptive device (PPIUCD) is well accepted and recommended for contraception. However, anxiety at the time of delivery may restrict the acceptance of a PPIUCD for its immediate insertion. So far there is limited evidence to conclude anything concrete on the association between the expulsion rates and the timing of insertion following a vaginal delivery. Thus, this study was undertaken to compare the expulsion rates in immediate and early insertions and their safety and complications. METHODS: This prospective comparative study was carried out over 17 months on women delivering vaginally in a tertiary care teaching hospital in South India. A copper device (CuT380A) was inserted using Kelly’s placental forceps either within 10 min of placental delivery (immediate group, n=160) or between 10 min upto 48 h postpartum (early group, n=160). Ultrasound was done before discharge from the hospital. The expulsion rates and any other complications at six-week and three-month follow up were studied. Chi-square test was used to compare the difference in expulsion rates. RESULTS: The expulsion rate was five per cent in the immediate compared to 3.7 per cent in the early group (no significant difference). In ten cases, the device was found to be in the lower uterus upon ultrasound before discharge. These were repositioned. There was no case with perforation, irregular bleeding or infection up to the three-month follow up. Higher age, higher parity, lack of satisfaction and motivation to continue were predictors of expulsion. INTERPRETATION & CONCLUSIONS: In the present study PPIUCD was found to be safe with overall expulsion in 4.3 per cent. It was marginally, though not significantly, higher in the immediate group. Wolters Kluwer - Medknow 2023-04 2023-05-31 /pmc/articles/PMC10438408/ /pubmed/37282395 http://dx.doi.org/10.4103/ijmr.IJMR_1485_19 Text en Copyright: © 2023 Indian Journal of Medical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Practice: Original Article
Dorairajan, Gowri
Ashok, Venkatesh M.
Veena, P.
Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title_full Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title_fullStr Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title_full_unstemmed Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title_short Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates
title_sort effect of the timing of insertion of postpartum intrauterine contraceptive device (ppiucd) copper t380a on expulsion rates
topic Practice: Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438408/
https://www.ncbi.nlm.nih.gov/pubmed/37282395
http://dx.doi.org/10.4103/ijmr.IJMR_1485_19
work_keys_str_mv AT dorairajangowri effectofthetimingofinsertionofpostpartumintrauterinecontraceptivedeviceppiucdcoppert380aonexpulsionrates
AT ashokvenkateshm effectofthetimingofinsertionofpostpartumintrauterinecontraceptivedeviceppiucdcoppert380aonexpulsionrates
AT veenap effectofthetimingofinsertionofpostpartumintrauterinecontraceptivedeviceppiucdcoppert380aonexpulsionrates