Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge

PURPOSE: To evaluate efficiency of grooving, nuclear fragment removal, and changes in pressure control in the Oertli Faros using traditional peristaltic and Speed and Precision (SPEEP) features. The SPEEP mode uses novel peristaltic technology permitting independent control of flow and vacuum. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Ricks, Reiker G, Cardenas, Ivan A, Ungricht, Emilie L, Olson, Randall J, Pettey, Jeff H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438468/
https://www.ncbi.nlm.nih.gov/pubmed/37600145
http://dx.doi.org/10.2147/OPTH.S416604
_version_ 1785092799008342016
author Ricks, Reiker G
Cardenas, Ivan A
Ungricht, Emilie L
Olson, Randall J
Pettey, Jeff H
author_facet Ricks, Reiker G
Cardenas, Ivan A
Ungricht, Emilie L
Olson, Randall J
Pettey, Jeff H
author_sort Ricks, Reiker G
collection PubMed
description PURPOSE: To evaluate efficiency of grooving, nuclear fragment removal, and changes in pressure control in the Oertli Faros using traditional peristaltic and Speed and Precision (SPEEP) features. The SPEEP mode uses novel peristaltic technology permitting independent control of flow and vacuum. METHODS: A porcine lens model was used with an enclosed chamber simulating the anterior segment. Grooving efficiency is evaluated with flow rates of 10, 30, and 50 mL/min using whole lenses. Lens cubes were emulsified at 20, 40, 60, 80, and 100% power with both SPEEP and non-SPEEP modes. Surge was evaluated with pressure gauges placed on the irrigation tubing and aspiration tubing. Pressure readings were recorded per the following: fluid and vacuum were initiated for 15 seconds, vacuum tubing was occluded for 5 seconds, tubing patency was then re-introduced for 15 seconds. Differences between sensors were recorded. RESULTS: No significant increase in efficiency was seen with increasing flow rate from 30 to 50 mL/min using SPEEP. No significant differences were shown in lens fragment removal in SPEEP and non-SPEEP modes at any power tested. Pressure difference measurements were not significantly different with SPEEP and non-SPEEP modes. CONCLUSION: We showed that lower flow rates show comparable efficiency of grooving when using the SPEEP mode. The SPEEP function did not show increased efficiency in nuclear fragment removal when compared to traditional mode. Surge control was also comparable with both SPEEP and non-SPEEP modes. We suggest that the SPEEP function included in the Oertli Faros may have some advantages.
format Online
Article
Text
id pubmed-10438468
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-104384682023-08-19 Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge Ricks, Reiker G Cardenas, Ivan A Ungricht, Emilie L Olson, Randall J Pettey, Jeff H Clin Ophthalmol Original Research PURPOSE: To evaluate efficiency of grooving, nuclear fragment removal, and changes in pressure control in the Oertli Faros using traditional peristaltic and Speed and Precision (SPEEP) features. The SPEEP mode uses novel peristaltic technology permitting independent control of flow and vacuum. METHODS: A porcine lens model was used with an enclosed chamber simulating the anterior segment. Grooving efficiency is evaluated with flow rates of 10, 30, and 50 mL/min using whole lenses. Lens cubes were emulsified at 20, 40, 60, 80, and 100% power with both SPEEP and non-SPEEP modes. Surge was evaluated with pressure gauges placed on the irrigation tubing and aspiration tubing. Pressure readings were recorded per the following: fluid and vacuum were initiated for 15 seconds, vacuum tubing was occluded for 5 seconds, tubing patency was then re-introduced for 15 seconds. Differences between sensors were recorded. RESULTS: No significant increase in efficiency was seen with increasing flow rate from 30 to 50 mL/min using SPEEP. No significant differences were shown in lens fragment removal in SPEEP and non-SPEEP modes at any power tested. Pressure difference measurements were not significantly different with SPEEP and non-SPEEP modes. CONCLUSION: We showed that lower flow rates show comparable efficiency of grooving when using the SPEEP mode. The SPEEP function did not show increased efficiency in nuclear fragment removal when compared to traditional mode. Surge control was also comparable with both SPEEP and non-SPEEP modes. We suggest that the SPEEP function included in the Oertli Faros may have some advantages. Dove 2023-08-14 /pmc/articles/PMC10438468/ /pubmed/37600145 http://dx.doi.org/10.2147/OPTH.S416604 Text en © 2023 Ricks et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Ricks, Reiker G
Cardenas, Ivan A
Ungricht, Emilie L
Olson, Randall J
Pettey, Jeff H
Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title_full Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title_fullStr Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title_full_unstemmed Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title_short Effect of Modified Peristaltic Phacoemulsification Device on Efficiency and Post-Occlusion Pressure Surge
title_sort effect of modified peristaltic phacoemulsification device on efficiency and post-occlusion pressure surge
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438468/
https://www.ncbi.nlm.nih.gov/pubmed/37600145
http://dx.doi.org/10.2147/OPTH.S416604
work_keys_str_mv AT ricksreikerg effectofmodifiedperistalticphacoemulsificationdeviceonefficiencyandpostocclusionpressuresurge
AT cardenasivana effectofmodifiedperistalticphacoemulsificationdeviceonefficiencyandpostocclusionpressuresurge
AT ungrichtemiliel effectofmodifiedperistalticphacoemulsificationdeviceonefficiencyandpostocclusionpressuresurge
AT olsonrandallj effectofmodifiedperistalticphacoemulsificationdeviceonefficiencyandpostocclusionpressuresurge
AT petteyjeffh effectofmodifiedperistalticphacoemulsificationdeviceonefficiencyandpostocclusionpressuresurge