Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft
Background and objective: The G-Branch endograft is a novel multibranched “off-the-shelf” device used to repair thoracoabdominal aortic aneurysms (TAAAs). This report describes the hemodynamic and morphological performance of the G-Branch endograft in a human patient with TAAA. Materials and methods...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438984/ https://www.ncbi.nlm.nih.gov/pubmed/37601633 http://dx.doi.org/10.3389/fphys.2023.1234989 |
_version_ | 1785092839690993664 |
---|---|
author | Wang, Jiabin Fan, Tingting Zhang, Hongpeng Ge, Yangyang Lu, Weihang Liu, Feng Rong, Dan Guo, Wei |
author_facet | Wang, Jiabin Fan, Tingting Zhang, Hongpeng Ge, Yangyang Lu, Weihang Liu, Feng Rong, Dan Guo, Wei |
author_sort | Wang, Jiabin |
collection | PubMed |
description | Background and objective: The G-Branch endograft is a novel multibranched “off-the-shelf” device used to repair thoracoabdominal aortic aneurysms (TAAAs). This report describes the hemodynamic and morphological performance of the G-Branch endograft in a human patient with TAAA. Materials and methods: We retrospectively reviewed the computed tomography angiography scans and clinical data of a woman in whom TAAA was treated using a G-Branch endograft. Patient-specific three-dimensional models were reconstructed, and computational fluid dynamics and morphological and hemodynamic indicators were analyzed before and after implantation of the device. Results: From a morphological perspective, there was an increase in cross-sectional area in the G-Branch endograft and all bridging stent grafts over time. Blood flow was redistributed among the renovisceral arteries, with a decrease in flow rate in the celiac artery and an increase in the left renal artery. Laminar blood flow was smoother and more rapid after implantation of the G-Branch device and remained stable during follow-up. In the bridging stent grafts, flow recirculation zones were found in the bridging zones of the celiac artery and superior mesenteric artery as well as the distal sealing zones of both renal arteries. Furthermore, higher time-averaged wall shear stress and a lower oscillatory index and relative resident time were found in the G-Branch endograft and bridging stent grafts. Quantitative analysis showed obvious reduction in the surface area ratio of the elevated time-averaged wall shear stress area and surface area ratio of the relative resident time after G-branch implantation. Conclusion: The revascularization of branch vessels occurred following G-branch implantation, with improvements arising not only from morphological changes but also from hemodynamic alterations. The long-term performance of the G-Branch endograft needs further investigation and clinical validation. |
format | Online Article Text |
id | pubmed-10438984 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104389842023-08-19 Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft Wang, Jiabin Fan, Tingting Zhang, Hongpeng Ge, Yangyang Lu, Weihang Liu, Feng Rong, Dan Guo, Wei Front Physiol Physiology Background and objective: The G-Branch endograft is a novel multibranched “off-the-shelf” device used to repair thoracoabdominal aortic aneurysms (TAAAs). This report describes the hemodynamic and morphological performance of the G-Branch endograft in a human patient with TAAA. Materials and methods: We retrospectively reviewed the computed tomography angiography scans and clinical data of a woman in whom TAAA was treated using a G-Branch endograft. Patient-specific three-dimensional models were reconstructed, and computational fluid dynamics and morphological and hemodynamic indicators were analyzed before and after implantation of the device. Results: From a morphological perspective, there was an increase in cross-sectional area in the G-Branch endograft and all bridging stent grafts over time. Blood flow was redistributed among the renovisceral arteries, with a decrease in flow rate in the celiac artery and an increase in the left renal artery. Laminar blood flow was smoother and more rapid after implantation of the G-Branch device and remained stable during follow-up. In the bridging stent grafts, flow recirculation zones were found in the bridging zones of the celiac artery and superior mesenteric artery as well as the distal sealing zones of both renal arteries. Furthermore, higher time-averaged wall shear stress and a lower oscillatory index and relative resident time were found in the G-Branch endograft and bridging stent grafts. Quantitative analysis showed obvious reduction in the surface area ratio of the elevated time-averaged wall shear stress area and surface area ratio of the relative resident time after G-branch implantation. Conclusion: The revascularization of branch vessels occurred following G-branch implantation, with improvements arising not only from morphological changes but also from hemodynamic alterations. The long-term performance of the G-Branch endograft needs further investigation and clinical validation. Frontiers Media S.A. 2023-08-04 /pmc/articles/PMC10438984/ /pubmed/37601633 http://dx.doi.org/10.3389/fphys.2023.1234989 Text en Copyright © 2023 Wang, Fan, Zhang, Ge, Lu, Liu, Rong and Guo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Wang, Jiabin Fan, Tingting Zhang, Hongpeng Ge, Yangyang Lu, Weihang Liu, Feng Rong, Dan Guo, Wei Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title | Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title_full | Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title_fullStr | Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title_full_unstemmed | Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title_short | Aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a G-Branch endograft |
title_sort | aortic hemodynamic and morphological analysis before and after repair of thoracoabdominal aortic aneurysm using a g-branch endograft |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10438984/ https://www.ncbi.nlm.nih.gov/pubmed/37601633 http://dx.doi.org/10.3389/fphys.2023.1234989 |
work_keys_str_mv | AT wangjiabin aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT fantingting aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT zhanghongpeng aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT geyangyang aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT luweihang aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT liufeng aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT rongdan aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft AT guowei aortichemodynamicandmorphologicalanalysisbeforeandafterrepairofthoracoabdominalaorticaneurysmusingagbranchendograft |