Cargando…

Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model

The usefulness of optical frequency domain imaging (OFDI) guidance on two-stenting at left main bifurcation has not been evaluated. Here, we used a novel bench model to investigate whether pre-defined optimal rewiring with OFDI-guidance decreases acute incomplete stent apposition (ISA) at the left m...

Descripción completa

Detalles Bibliográficos
Autores principales: Okamura, Takayuki, Iwasaki, Kiyotaka, Lu, Hongze, Zhu, Xiaodong, Fujimura, Tatsuhiro, Kitaba, Norika, Murakami, Keisuke, Nakamura, Ryota, Mitsui, Haruki, Tsuboko, Yusuke, Miyazaki, Yousuke, Matsuyama, Tetsuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10439901/
https://www.ncbi.nlm.nih.gov/pubmed/37598246
http://dx.doi.org/10.1038/s41598-023-40606-7
_version_ 1785093052658876416
author Okamura, Takayuki
Iwasaki, Kiyotaka
Lu, Hongze
Zhu, Xiaodong
Fujimura, Tatsuhiro
Kitaba, Norika
Murakami, Keisuke
Nakamura, Ryota
Mitsui, Haruki
Tsuboko, Yusuke
Miyazaki, Yousuke
Matsuyama, Tetsuya
author_facet Okamura, Takayuki
Iwasaki, Kiyotaka
Lu, Hongze
Zhu, Xiaodong
Fujimura, Tatsuhiro
Kitaba, Norika
Murakami, Keisuke
Nakamura, Ryota
Mitsui, Haruki
Tsuboko, Yusuke
Miyazaki, Yousuke
Matsuyama, Tetsuya
author_sort Okamura, Takayuki
collection PubMed
description The usefulness of optical frequency domain imaging (OFDI) guidance on two-stenting at left main bifurcation has not been evaluated. Here, we used a novel bench model to investigate whether pre-defined optimal rewiring with OFDI-guidance decreases acute incomplete stent apposition (ISA) at the left main bifurcation segment. A novel bench simulation system was developed to simulate the foreshortening and overlapping of daughter vessels as well as left main bifurcation motion under fluoroscopy. Double-kissing (DK) culotte stenting was performed using the novel bench model under fluoroscopy with or without OFDI-guidance. In the OFDI-guidance group, if the guidewire did not pass through the pre-defined optimal cell according to the 3-dimensional OFDI, additional attempts of rewiring into the jailed side branch were performed. The success rate of optimal jailed side branch rewiring after implantation of the first and second stent under OFDI-guidance was significantly higher than that under only angio-guidance. After completion of the DK-culotte stenting, the incidence and volume of ISA at the bifurcation segment in the OFDI-guidance group was significantly lower than that in the angio-guidance group. Online 3-dimensional OFDI-guided DK-culotte stenting according to a pre-defined optimal rewiring point might be superior to only angio-guided rewiring for reducing ISA at the bifurcation.
format Online
Article
Text
id pubmed-10439901
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-104399012023-08-21 Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model Okamura, Takayuki Iwasaki, Kiyotaka Lu, Hongze Zhu, Xiaodong Fujimura, Tatsuhiro Kitaba, Norika Murakami, Keisuke Nakamura, Ryota Mitsui, Haruki Tsuboko, Yusuke Miyazaki, Yousuke Matsuyama, Tetsuya Sci Rep Article The usefulness of optical frequency domain imaging (OFDI) guidance on two-stenting at left main bifurcation has not been evaluated. Here, we used a novel bench model to investigate whether pre-defined optimal rewiring with OFDI-guidance decreases acute incomplete stent apposition (ISA) at the left main bifurcation segment. A novel bench simulation system was developed to simulate the foreshortening and overlapping of daughter vessels as well as left main bifurcation motion under fluoroscopy. Double-kissing (DK) culotte stenting was performed using the novel bench model under fluoroscopy with or without OFDI-guidance. In the OFDI-guidance group, if the guidewire did not pass through the pre-defined optimal cell according to the 3-dimensional OFDI, additional attempts of rewiring into the jailed side branch were performed. The success rate of optimal jailed side branch rewiring after implantation of the first and second stent under OFDI-guidance was significantly higher than that under only angio-guidance. After completion of the DK-culotte stenting, the incidence and volume of ISA at the bifurcation segment in the OFDI-guidance group was significantly lower than that in the angio-guidance group. Online 3-dimensional OFDI-guided DK-culotte stenting according to a pre-defined optimal rewiring point might be superior to only angio-guided rewiring for reducing ISA at the bifurcation. Nature Publishing Group UK 2023-08-19 /pmc/articles/PMC10439901/ /pubmed/37598246 http://dx.doi.org/10.1038/s41598-023-40606-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Okamura, Takayuki
Iwasaki, Kiyotaka
Lu, Hongze
Zhu, Xiaodong
Fujimura, Tatsuhiro
Kitaba, Norika
Murakami, Keisuke
Nakamura, Ryota
Mitsui, Haruki
Tsuboko, Yusuke
Miyazaki, Yousuke
Matsuyama, Tetsuya
Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title_full Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title_fullStr Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title_full_unstemmed Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title_short Importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
title_sort importance of optimal rewiring guided by 3-dimensional optical frequency domain imaging during double-kissing culotte stenting demonstrated through a novel bench model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10439901/
https://www.ncbi.nlm.nih.gov/pubmed/37598246
http://dx.doi.org/10.1038/s41598-023-40606-7
work_keys_str_mv AT okamuratakayuki importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT iwasakikiyotaka importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT luhongze importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT zhuxiaodong importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT fujimuratatsuhiro importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT kitabanorika importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT murakamikeisuke importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT nakamuraryota importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT mitsuiharuki importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT tsubokoyusuke importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT miyazakiyousuke importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel
AT matsuyamatetsuya importanceofoptimalrewiringguidedby3dimensionalopticalfrequencydomainimagingduringdoublekissingculottestentingdemonstratedthroughanovelbenchmodel