Cargando…

Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications

OBJECTIVE: To discuss the relationship between time in range (TIR) which is deprived of the FGMS and the risk of diabetic vascular complications and to provide a theoretical foundation for the clinical application of TIR and other FGMS-deprived indexes. METHODS: Patients with T2DM who wore the FGMS...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheng, Xia, Li, Ting, Hu, Yi, Xiong, Cheng-Shun, Hu, Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440601/
https://www.ncbi.nlm.nih.gov/pubmed/37608851
http://dx.doi.org/10.2147/DMSO.S418224
_version_ 1785093192574566400
author Sheng, Xia
Li, Ting
Hu, Yi
Xiong, Cheng-Shun
Hu, Ling
author_facet Sheng, Xia
Li, Ting
Hu, Yi
Xiong, Cheng-Shun
Hu, Ling
author_sort Sheng, Xia
collection PubMed
description OBJECTIVE: To discuss the relationship between time in range (TIR) which is deprived of the FGMS and the risk of diabetic vascular complications and to provide a theoretical foundation for the clinical application of TIR and other FGMS-deprived indexes. METHODS: Patients with T2DM who wore the FGMS sensor continuously were enrolled. Relevant indexes such as TIR, time below range (TBR), time above range (TAR), a standard deviation of blood glucose (SDBG), coefficient of variation of blood glucose (CV), and mean amplitude of glycemic excursion (MAGE) generated by the FGMS were recorded, and the risk of diabetic vascular complications were followed up for one year. The TIR was measured by continuous glucose monitoring at baseline, and patients were grouped according to TIR every 20%. Finally, the Cox proportional hazards regression model was used to estimate the association of different levels of TIR with different rates of diabetic vascular complications. RESULTS: TIR was negatively correlated with HbA1C, CV, SDBG, and amplitude of glycemic excursion (MV), wherein, the lower the TIR, the higher the HbA1C, CV, SDBG, and MV. TIR in the diabetic microvascular complication was significantly lower than that in the non-microvascular complication group, and the difference was statistically significant. TIR <40% was identified as a risk factor for DN, DPN, and DR according to the risk assessment. The mean TAR in the DN group was significantly higher than that in the non-DN group. TAR, CV, SD, MAGE, and HbA1C in the DR group were significantly higher than those in the non-DR group. TAR, ABG, CV, SD, MAGE, and HbA1C in the DPN group were significantly higher than those in the non-DPN group. CONCLUSION: The relationships between the TIR and the prevalence and risk of diabetic vascular complications and the HbA1C may be negative. Other CGM-deprived indexes such as CV and MV should be integrated into glycemic control and diabetes complication prediction.
format Online
Article
Text
id pubmed-10440601
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-104406012023-08-22 Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications Sheng, Xia Li, Ting Hu, Yi Xiong, Cheng-Shun Hu, Ling Diabetes Metab Syndr Obes Original Research OBJECTIVE: To discuss the relationship between time in range (TIR) which is deprived of the FGMS and the risk of diabetic vascular complications and to provide a theoretical foundation for the clinical application of TIR and other FGMS-deprived indexes. METHODS: Patients with T2DM who wore the FGMS sensor continuously were enrolled. Relevant indexes such as TIR, time below range (TBR), time above range (TAR), a standard deviation of blood glucose (SDBG), coefficient of variation of blood glucose (CV), and mean amplitude of glycemic excursion (MAGE) generated by the FGMS were recorded, and the risk of diabetic vascular complications were followed up for one year. The TIR was measured by continuous glucose monitoring at baseline, and patients were grouped according to TIR every 20%. Finally, the Cox proportional hazards regression model was used to estimate the association of different levels of TIR with different rates of diabetic vascular complications. RESULTS: TIR was negatively correlated with HbA1C, CV, SDBG, and amplitude of glycemic excursion (MV), wherein, the lower the TIR, the higher the HbA1C, CV, SDBG, and MV. TIR in the diabetic microvascular complication was significantly lower than that in the non-microvascular complication group, and the difference was statistically significant. TIR <40% was identified as a risk factor for DN, DPN, and DR according to the risk assessment. The mean TAR in the DN group was significantly higher than that in the non-DN group. TAR, CV, SD, MAGE, and HbA1C in the DR group were significantly higher than those in the non-DR group. TAR, ABG, CV, SD, MAGE, and HbA1C in the DPN group were significantly higher than those in the non-DPN group. CONCLUSION: The relationships between the TIR and the prevalence and risk of diabetic vascular complications and the HbA1C may be negative. Other CGM-deprived indexes such as CV and MV should be integrated into glycemic control and diabetes complication prediction. Dove 2023-08-16 /pmc/articles/PMC10440601/ /pubmed/37608851 http://dx.doi.org/10.2147/DMSO.S418224 Text en © 2023 Sheng et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Sheng, Xia
Li, Ting
Hu, Yi
Xiong, Cheng-Shun
Hu, Ling
Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title_full Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title_fullStr Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title_full_unstemmed Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title_short Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
title_sort correlation between blood glucose indexes generated by the flash glucose monitoring system and diabetic vascular complications
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440601/
https://www.ncbi.nlm.nih.gov/pubmed/37608851
http://dx.doi.org/10.2147/DMSO.S418224
work_keys_str_mv AT shengxia correlationbetweenbloodglucoseindexesgeneratedbytheflashglucosemonitoringsystemanddiabeticvascularcomplications
AT liting correlationbetweenbloodglucoseindexesgeneratedbytheflashglucosemonitoringsystemanddiabeticvascularcomplications
AT huyi correlationbetweenbloodglucoseindexesgeneratedbytheflashglucosemonitoringsystemanddiabeticvascularcomplications
AT xiongchengshun correlationbetweenbloodglucoseindexesgeneratedbytheflashglucosemonitoringsystemanddiabeticvascularcomplications
AT huling correlationbetweenbloodglucoseindexesgeneratedbytheflashglucosemonitoringsystemanddiabeticvascularcomplications