Cargando…

Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis

INTRODUCTION: This systematic review and meta-analysis aimed to summarize the evidence regarding the impact of needle direction and distance of arteriovenous fistula (AVF) cannulation on KT/V (where k is the dialyzer urea clearance, t, the duration of dialysis, and V, the volume of distribution of u...

Descripción completa

Detalles Bibliográficos
Autores principales: Karkhah, Samad, Pourshaikhian, Majid, Ghorbani Vajargah, Pooyan, Zaboli Mahdiabadi, Morteza, Mollaei, Amirabbas, Maroufizadeh, Saman, Hosseini, Seyed Javad, Osuji, Joseph, Moghadamnia, Mohammad Taghi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shahid Beheshti University of Medical Sciences 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440757/
https://www.ncbi.nlm.nih.gov/pubmed/37609532
http://dx.doi.org/10.22037/aaem.v11i1.1943
_version_ 1785093221110513664
author Karkhah, Samad
Pourshaikhian, Majid
Ghorbani Vajargah, Pooyan
Zaboli Mahdiabadi, Morteza
Mollaei, Amirabbas
Maroufizadeh, Saman
Hosseini, Seyed Javad
Osuji, Joseph
Moghadamnia, Mohammad Taghi
author_facet Karkhah, Samad
Pourshaikhian, Majid
Ghorbani Vajargah, Pooyan
Zaboli Mahdiabadi, Morteza
Mollaei, Amirabbas
Maroufizadeh, Saman
Hosseini, Seyed Javad
Osuji, Joseph
Moghadamnia, Mohammad Taghi
author_sort Karkhah, Samad
collection PubMed
description INTRODUCTION: This systematic review and meta-analysis aimed to summarize the evidence regarding the impact of needle direction and distance of arteriovenous fistula (AVF) cannulation on KT/V (where k is the dialyzer urea clearance, t, the duration of dialysis, and V, the volume of distribution of urea) and access recirculation (AR) as hemodialysis (HD) adequacy criteria. METHODS: A comprehensive systematic search was performed on international and domestic electronic databases from the earliest to June 4, 2022 using keywords. Analysis was performed in STATA software v.14. RESULTS: Three randomized control trials (RCTs) and four non-RCT articles were included in the final review. Six studies reported the effects of direction, while four mentioned the effects of distances of AVF cannulation on outcomes of HD adequacy based on KT/V or AR. Results of three non-RCT studies showed that retrograde direction decreased KT/V more than antegrade direction (ES: 0.44, 95% CI: -0.38 to 1.27). Two non-RCT studies showed that antegrade decreased AR compared to the retrograde direction (ES: -0.64, 95%CI: -1.94 to 0.67). However, the results of two RCTs indicated uncertainty about this issue. Two of the four studies suggested that a distance of 5 cm or more in arterial and venous needles had greater adequacy than a distance of less than 5 cm. However, other studies did not confirm this finding. CONCLUSION: Overall comparison of the results qualitatively and quantitatively indicated uncertainty about the effects of direction and distance of AVF cannulation on HD adequacy outcomes. More studies with high-quality designs, such as RCTs, are required to better understand and adjudicate the effects of needle direction and distance of AVF cannulation on HD adequacy outcomes.
format Online
Article
Text
id pubmed-10440757
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Shahid Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-104407572023-08-22 Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis Karkhah, Samad Pourshaikhian, Majid Ghorbani Vajargah, Pooyan Zaboli Mahdiabadi, Morteza Mollaei, Amirabbas Maroufizadeh, Saman Hosseini, Seyed Javad Osuji, Joseph Moghadamnia, Mohammad Taghi Arch Acad Emerg Med Review Article INTRODUCTION: This systematic review and meta-analysis aimed to summarize the evidence regarding the impact of needle direction and distance of arteriovenous fistula (AVF) cannulation on KT/V (where k is the dialyzer urea clearance, t, the duration of dialysis, and V, the volume of distribution of urea) and access recirculation (AR) as hemodialysis (HD) adequacy criteria. METHODS: A comprehensive systematic search was performed on international and domestic electronic databases from the earliest to June 4, 2022 using keywords. Analysis was performed in STATA software v.14. RESULTS: Three randomized control trials (RCTs) and four non-RCT articles were included in the final review. Six studies reported the effects of direction, while four mentioned the effects of distances of AVF cannulation on outcomes of HD adequacy based on KT/V or AR. Results of three non-RCT studies showed that retrograde direction decreased KT/V more than antegrade direction (ES: 0.44, 95% CI: -0.38 to 1.27). Two non-RCT studies showed that antegrade decreased AR compared to the retrograde direction (ES: -0.64, 95%CI: -1.94 to 0.67). However, the results of two RCTs indicated uncertainty about this issue. Two of the four studies suggested that a distance of 5 cm or more in arterial and venous needles had greater adequacy than a distance of less than 5 cm. However, other studies did not confirm this finding. CONCLUSION: Overall comparison of the results qualitatively and quantitatively indicated uncertainty about the effects of direction and distance of AVF cannulation on HD adequacy outcomes. More studies with high-quality designs, such as RCTs, are required to better understand and adjudicate the effects of needle direction and distance of AVF cannulation on HD adequacy outcomes. Shahid Beheshti University of Medical Sciences 2023-05-20 /pmc/articles/PMC10440757/ /pubmed/37609532 http://dx.doi.org/10.22037/aaem.v11i1.1943 Text en https://creativecommons.org/licenses/by-nc/3.0/This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). (https://creativecommons.org/licenses/by-nc/3.0/)
spellingShingle Review Article
Karkhah, Samad
Pourshaikhian, Majid
Ghorbani Vajargah, Pooyan
Zaboli Mahdiabadi, Morteza
Mollaei, Amirabbas
Maroufizadeh, Saman
Hosseini, Seyed Javad
Osuji, Joseph
Moghadamnia, Mohammad Taghi
Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title_full Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title_fullStr Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title_full_unstemmed Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title_short Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis
title_sort needle direction and distance of arteriovenous fistula cannulation in hemodialysis adequacy; a systematic review and meta-analysis
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440757/
https://www.ncbi.nlm.nih.gov/pubmed/37609532
http://dx.doi.org/10.22037/aaem.v11i1.1943
work_keys_str_mv AT karkhahsamad needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT pourshaikhianmajid needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT ghorbanivajargahpooyan needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT zabolimahdiabadimorteza needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT mollaeiamirabbas needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT maroufizadehsaman needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT hosseiniseyedjavad needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT osujijoseph needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis
AT moghadamniamohammadtaghi needledirectionanddistanceofarteriovenousfistulacannulationinhemodialysisadequacyasystematicreviewandmetaanalysis