Cargando…
Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conduct...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441160/ https://www.ncbi.nlm.nih.gov/pubmed/37609102 http://dx.doi.org/10.7759/cureus.42291 |
_version_ | 1785093317554339840 |
---|---|
author | Sharaf, Omar M Hao, Kevin A Demos, Daniel S Plowman, Emily K Ahmed, Mustafa M Jeng, Eric I |
author_facet | Sharaf, Omar M Hao, Kevin A Demos, Daniel S Plowman, Emily K Ahmed, Mustafa M Jeng, Eric I |
author_sort | Sharaf, Omar M |
collection | PubMed |
description | Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conducted in adults (≥18 years of age) undergoing durable LVAD (February 2019 - January 2020). Six patients were prospectively enrolled, evaluated, and underwent FEES within 72 hours of extubation-they were compared to 12 control patients. Demographic, surgical, and postoperative outcomes were collected. Unpaired two-sided t-tests and Fisher’s exact tests were performed. Results Baseline characteristics were similar between groups. Intraoperative criteria including duration of transesophageal echo (314 ± 86 min) and surgery (301 ± 74 min) did not differ. The mean time of intubation was comparable (57.3 vs. 68.7 hours, p=0.77). In the entire cohort, 30-day, one-year, two-year, and three-year mortality were 0%, 5.6%, 5.6%, and 16.7%, respectively. Sixty-seven percent of the patients that underwent FEES had inefficient swallowing function. The FEES group trended to a shorter hospital length of stay (LOS) (29.1 vs. 46.6 days, p=0.098), post-implantation LOS (25.3 vs 30.7 days, p=0.46), and lower incidence of postoperative pneumonia (16.7% vs. 50%, p=0.32) and sepsis (0% vs. 33.3%, p=0.25). Conclusion FEES did not impact 30-day, one-year, two-year, or three-year mortality. Though not statistically significant, patients who underwent FEES trended toward shorter LOS and lower postoperative pneumonia and sepsis rates. Additionally, we report a higher incidence of dysphagia among patients undergoing FEES despite comparable baseline risk factors with controls. |
format | Online Article Text |
id | pubmed-10441160 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-104411602023-08-22 Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation Sharaf, Omar M Hao, Kevin A Demos, Daniel S Plowman, Emily K Ahmed, Mustafa M Jeng, Eric I Cureus Cardiac/Thoracic/Vascular Surgery Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conducted in adults (≥18 years of age) undergoing durable LVAD (February 2019 - January 2020). Six patients were prospectively enrolled, evaluated, and underwent FEES within 72 hours of extubation-they were compared to 12 control patients. Demographic, surgical, and postoperative outcomes were collected. Unpaired two-sided t-tests and Fisher’s exact tests were performed. Results Baseline characteristics were similar between groups. Intraoperative criteria including duration of transesophageal echo (314 ± 86 min) and surgery (301 ± 74 min) did not differ. The mean time of intubation was comparable (57.3 vs. 68.7 hours, p=0.77). In the entire cohort, 30-day, one-year, two-year, and three-year mortality were 0%, 5.6%, 5.6%, and 16.7%, respectively. Sixty-seven percent of the patients that underwent FEES had inefficient swallowing function. The FEES group trended to a shorter hospital length of stay (LOS) (29.1 vs. 46.6 days, p=0.098), post-implantation LOS (25.3 vs 30.7 days, p=0.46), and lower incidence of postoperative pneumonia (16.7% vs. 50%, p=0.32) and sepsis (0% vs. 33.3%, p=0.25). Conclusion FEES did not impact 30-day, one-year, two-year, or three-year mortality. Though not statistically significant, patients who underwent FEES trended toward shorter LOS and lower postoperative pneumonia and sepsis rates. Additionally, we report a higher incidence of dysphagia among patients undergoing FEES despite comparable baseline risk factors with controls. Cureus 2023-07-22 /pmc/articles/PMC10441160/ /pubmed/37609102 http://dx.doi.org/10.7759/cureus.42291 Text en Copyright © 2023, Sharaf et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Sharaf, Omar M Hao, Kevin A Demos, Daniel S Plowman, Emily K Ahmed, Mustafa M Jeng, Eric I Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title | Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title_full | Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title_fullStr | Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title_full_unstemmed | Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title_short | Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation |
title_sort | utility of fiberoptic endoscopic evaluation of swallowing after left ventricular assist device implantation |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441160/ https://www.ncbi.nlm.nih.gov/pubmed/37609102 http://dx.doi.org/10.7759/cureus.42291 |
work_keys_str_mv | AT sharafomarm utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation AT haokevina utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation AT demosdaniels utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation AT plowmanemilyk utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation AT ahmedmustafam utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation AT jengerici utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation |