Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation

Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conduct...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharaf, Omar M, Hao, Kevin A, Demos, Daniel S, Plowman, Emily K, Ahmed, Mustafa M, Jeng, Eric I
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441160/
https://www.ncbi.nlm.nih.gov/pubmed/37609102
http://dx.doi.org/10.7759/cureus.42291
_version_ 1785093317554339840
author Sharaf, Omar M
Hao, Kevin A
Demos, Daniel S
Plowman, Emily K
Ahmed, Mustafa M
Jeng, Eric I
author_facet Sharaf, Omar M
Hao, Kevin A
Demos, Daniel S
Plowman, Emily K
Ahmed, Mustafa M
Jeng, Eric I
author_sort Sharaf, Omar M
collection PubMed
description Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conducted in adults (≥18 years of age) undergoing durable LVAD (February 2019 - January 2020). Six patients were prospectively enrolled, evaluated, and underwent FEES within 72 hours of extubation-they were compared to 12 control patients. Demographic, surgical, and postoperative outcomes were collected. Unpaired two-sided t-tests and Fisher’s exact tests were performed. Results Baseline characteristics were similar between groups. Intraoperative criteria including duration of transesophageal echo (314 ± 86 min) and surgery (301 ± 74 min) did not differ. The mean time of intubation was comparable (57.3 vs. 68.7 hours, p=0.77). In the entire cohort, 30-day, one-year, two-year, and three-year mortality were 0%, 5.6%, 5.6%, and 16.7%, respectively. Sixty-seven percent of the patients that underwent FEES had inefficient swallowing function. The FEES group trended to a shorter hospital length of stay (LOS) (29.1 vs. 46.6 days, p=0.098), post-implantation LOS (25.3 vs 30.7 days, p=0.46), and lower incidence of postoperative pneumonia (16.7% vs. 50%, p=0.32) and sepsis (0% vs. 33.3%, p=0.25). Conclusion FEES did not impact 30-day, one-year, two-year, or three-year mortality. Though not statistically significant, patients who underwent FEES trended toward shorter LOS and lower postoperative pneumonia and sepsis rates. Additionally, we report a higher incidence of dysphagia among patients undergoing FEES despite comparable baseline risk factors with controls.
format Online
Article
Text
id pubmed-10441160
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-104411602023-08-22 Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation Sharaf, Omar M Hao, Kevin A Demos, Daniel S Plowman, Emily K Ahmed, Mustafa M Jeng, Eric I Cureus Cardiac/Thoracic/Vascular Surgery Objective Dysphagia following cardiac surgery is common and associated with adverse outcomes. Among patients receiving left ventricular assist devices (LVAD), we evaluated the impact of fiberoptic endoscopic evaluation of swallowing (FEES) on outcomes. Methods A single-center pilot study was conducted in adults (≥18 years of age) undergoing durable LVAD (February 2019 - January 2020). Six patients were prospectively enrolled, evaluated, and underwent FEES within 72 hours of extubation-they were compared to 12 control patients. Demographic, surgical, and postoperative outcomes were collected. Unpaired two-sided t-tests and Fisher’s exact tests were performed. Results Baseline characteristics were similar between groups. Intraoperative criteria including duration of transesophageal echo (314 ± 86 min) and surgery (301 ± 74 min) did not differ. The mean time of intubation was comparable (57.3 vs. 68.7 hours, p=0.77). In the entire cohort, 30-day, one-year, two-year, and three-year mortality were 0%, 5.6%, 5.6%, and 16.7%, respectively. Sixty-seven percent of the patients that underwent FEES had inefficient swallowing function. The FEES group trended to a shorter hospital length of stay (LOS) (29.1 vs. 46.6 days, p=0.098), post-implantation LOS (25.3 vs 30.7 days, p=0.46), and lower incidence of postoperative pneumonia (16.7% vs. 50%, p=0.32) and sepsis (0% vs. 33.3%, p=0.25). Conclusion FEES did not impact 30-day, one-year, two-year, or three-year mortality. Though not statistically significant, patients who underwent FEES trended toward shorter LOS and lower postoperative pneumonia and sepsis rates. Additionally, we report a higher incidence of dysphagia among patients undergoing FEES despite comparable baseline risk factors with controls. Cureus 2023-07-22 /pmc/articles/PMC10441160/ /pubmed/37609102 http://dx.doi.org/10.7759/cureus.42291 Text en Copyright © 2023, Sharaf et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Sharaf, Omar M
Hao, Kevin A
Demos, Daniel S
Plowman, Emily K
Ahmed, Mustafa M
Jeng, Eric I
Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title_full Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title_fullStr Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title_full_unstemmed Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title_short Utility of Fiberoptic Endoscopic Evaluation of Swallowing After Left Ventricular Assist Device Implantation
title_sort utility of fiberoptic endoscopic evaluation of swallowing after left ventricular assist device implantation
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441160/
https://www.ncbi.nlm.nih.gov/pubmed/37609102
http://dx.doi.org/10.7759/cureus.42291
work_keys_str_mv AT sharafomarm utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation
AT haokevina utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation
AT demosdaniels utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation
AT plowmanemilyk utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation
AT ahmedmustafam utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation
AT jengerici utilityoffiberopticendoscopicevaluationofswallowingafterleftventricularassistdeviceimplantation