Cargando…
A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study)
BACKGROUND: Retainer is a necessary procedure when orthodontic treatment complete to avoid relapse due to periodontal fiber elasticity and to allow for alveolar bone regeneration. Compare the influence of vertical force on the failure of three fixed retainers: CAD/CAM polyether ether ketone (PEEK),...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441729/ https://www.ncbi.nlm.nih.gov/pubmed/37605187 http://dx.doi.org/10.1186/s12903-023-03268-5 |
_version_ | 1785093436018262016 |
---|---|
author | Alabbadi , Abdullah A. Abdalla, Essam M. Hanafy, Seham A. Yousry, Tarek N. |
author_facet | Alabbadi , Abdullah A. Abdalla, Essam M. Hanafy, Seham A. Yousry, Tarek N. |
author_sort | Alabbadi , Abdullah A. |
collection | PubMed |
description | BACKGROUND: Retainer is a necessary procedure when orthodontic treatment complete to avoid relapse due to periodontal fiber elasticity and to allow for alveolar bone regeneration. Compare the influence of vertical force on the failure of three fixed retainers: CAD/CAM polyether ether ketone (PEEK), CAD/CAM fiber glass reinforced composites (FRCs), and lingual retainer wire “Bond-A-Braid™”. MATERIALS AND METHODS: One hundred and eight maxillary first premolars teeth were randomly allocated to three groups: Group A (CAD/CAM PEEK), Group B (CAD/CAM FRC), and Group C (lingual retainer wire " Bond-A-Braid™”). These retainers were bonded using Assure Plus Bonding Resin and GO TO Paste. For each specimen, a loading cycling and thermocycling machine was used. The failure debonding forces were measured on the interproximal segments using a universal testing machine with a cross-head speed of 1 mm/min. The adhesive remnant index (ARI) was calculated after identifying types of failure with a stereomicroscope at (X 20) magnification. RESULTS: Group B and group C showed the highest failure bonding forces, with a mean of 209.67 ± 16.15 and 86.81 ± 4.59 N, respectively. However, Group A had a statistically significant lower bond failure force, with a mean value of 45.73 ± 4.48 N. At baseline, there was a statistically significant difference in connector retainer displacement between the three studied groups (p < .001). The ARI score was not statistically significant (p < .001) between the three study groups; for groups A and B, the ARI was predominantly score 3, and group C showed a mixed score of 2 and 3. The failure mode of retainers was investigated using an optical stereomicroscope. In group B, there was a cohesive breakdown in the retainer, and groups A and C exhibited failures primarily in the adhesive at the retainer interface. CONCLUSION: All groups differed significantly, with group A having the lowest debonding force and group B having the highest. Furthermore, there was not a substantial variation in ARI, but there was a significant difference in connector retainer displacement and the types of failure amongst the three groups. |
format | Online Article Text |
id | pubmed-10441729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104417292023-08-22 A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) Alabbadi , Abdullah A. Abdalla, Essam M. Hanafy, Seham A. Yousry, Tarek N. BMC Oral Health Research BACKGROUND: Retainer is a necessary procedure when orthodontic treatment complete to avoid relapse due to periodontal fiber elasticity and to allow for alveolar bone regeneration. Compare the influence of vertical force on the failure of three fixed retainers: CAD/CAM polyether ether ketone (PEEK), CAD/CAM fiber glass reinforced composites (FRCs), and lingual retainer wire “Bond-A-Braid™”. MATERIALS AND METHODS: One hundred and eight maxillary first premolars teeth were randomly allocated to three groups: Group A (CAD/CAM PEEK), Group B (CAD/CAM FRC), and Group C (lingual retainer wire " Bond-A-Braid™”). These retainers were bonded using Assure Plus Bonding Resin and GO TO Paste. For each specimen, a loading cycling and thermocycling machine was used. The failure debonding forces were measured on the interproximal segments using a universal testing machine with a cross-head speed of 1 mm/min. The adhesive remnant index (ARI) was calculated after identifying types of failure with a stereomicroscope at (X 20) magnification. RESULTS: Group B and group C showed the highest failure bonding forces, with a mean of 209.67 ± 16.15 and 86.81 ± 4.59 N, respectively. However, Group A had a statistically significant lower bond failure force, with a mean value of 45.73 ± 4.48 N. At baseline, there was a statistically significant difference in connector retainer displacement between the three studied groups (p < .001). The ARI score was not statistically significant (p < .001) between the three study groups; for groups A and B, the ARI was predominantly score 3, and group C showed a mixed score of 2 and 3. The failure mode of retainers was investigated using an optical stereomicroscope. In group B, there was a cohesive breakdown in the retainer, and groups A and C exhibited failures primarily in the adhesive at the retainer interface. CONCLUSION: All groups differed significantly, with group A having the lowest debonding force and group B having the highest. Furthermore, there was not a substantial variation in ARI, but there was a significant difference in connector retainer displacement and the types of failure amongst the three groups. BioMed Central 2023-08-21 /pmc/articles/PMC10441729/ /pubmed/37605187 http://dx.doi.org/10.1186/s12903-023-03268-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Alabbadi , Abdullah A. Abdalla, Essam M. Hanafy, Seham A. Yousry, Tarek N. A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title | A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title_full | A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title_fullStr | A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title_full_unstemmed | A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title_short | A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
title_sort | comparative study of cad/cam fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study) |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10441729/ https://www.ncbi.nlm.nih.gov/pubmed/37605187 http://dx.doi.org/10.1186/s12903-023-03268-5 |
work_keys_str_mv | AT alabbadiabdullaha acomparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT abdallaessamm acomparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT hanafysehama acomparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT yousrytarekn acomparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT alabbadiabdullaha comparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT abdallaessamm comparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT hanafysehama comparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy AT yousrytarekn comparativestudyofcadcamfabricatedpolyetheretherketoneandfiberglassreinforcementcompositesversusmetallingualretainersunderverticalloadaninvitrostudy |