Cargando…
ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY
PURPOSE: To investigate the performance of novel intraocular lens calculation formulae (Barrett Universal II, Emmetropia Verifying Optical, and Kane) and conventional formulae (Haigis, Hoffer Q, Holladay 1, and Sanders‐Retzlaff‐Kraff/T [SRK/T]) in patients who underwent pars plana vitrectomy or sili...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Retina
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10442118/ https://www.ncbi.nlm.nih.gov/pubmed/37307580 http://dx.doi.org/10.1097/IAE.0000000000003846 |
_version_ | 1785093519326576640 |
---|---|
author | Chen, Xu Zhao, He Xu, Yufei Qin, Zuoxin Ren, Jiayun Wang, Lu Wan, Junli Wang, Ziran Liu, Bo Wu, Nan Liu, Xi Liu, Yong |
author_facet | Chen, Xu Zhao, He Xu, Yufei Qin, Zuoxin Ren, Jiayun Wang, Lu Wan, Junli Wang, Ziran Liu, Bo Wu, Nan Liu, Xi Liu, Yong |
author_sort | Chen, Xu |
collection | PubMed |
description | PURPOSE: To investigate the performance of novel intraocular lens calculation formulae (Barrett Universal II, Emmetropia Verifying Optical, and Kane) and conventional formulae (Haigis, Hoffer Q, Holladay 1, and Sanders‐Retzlaff‐Kraff/T [SRK/T]) in patients who underwent pars plana vitrectomy or silicone oil removal combined with cataract surgery. METHODS: In total, 301 eyes from 301 patients who underwent pars plana vitrectomy/silicone oil removal with concomitant cataract surgery were enrolled and divided into the following four groups according to preoperative diagnosis: silicone oil–filled eyes after pars plana vitrectomy, epiretinal membrane, primary retinal detachment, and macular hole. RESULTS: Barrett Universal II exhibited the smallest mean absolute error (0.65 diopters [D]) and median absolute error (0.39 D) in total. In patients with primary retinal detachment, each formula exhibited the worst refractive outcomes in diverse vitreoretinal pathologies (P < 0.01), and no difference in accuracy between the seven formulas was observed (P = 0.075). For long eyes, the second linear (Wang–Koch 2) version of the Wang–Koch adjustment significantly reduced the median absolute error for Holladay 1 and SRK/T (P < 0.001 and P = 0.019). CONCLUSION: In combined surgery, both new and conventional formulas using the second linear version of the Wang–Koch 2 adjustment demonstrated satisfactory performance, with Barrett Universal II exhibiting the best overall performance. However, in patients with primary retinal detachment, all seven formulas showed less favorable performance. |
format | Online Article Text |
id | pubmed-10442118 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Retina |
record_format | MEDLINE/PubMed |
spelling | pubmed-104421182023-08-22 ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY Chen, Xu Zhao, He Xu, Yufei Qin, Zuoxin Ren, Jiayun Wang, Lu Wan, Junli Wang, Ziran Liu, Bo Wu, Nan Liu, Xi Liu, Yong Retina Original Study PURPOSE: To investigate the performance of novel intraocular lens calculation formulae (Barrett Universal II, Emmetropia Verifying Optical, and Kane) and conventional formulae (Haigis, Hoffer Q, Holladay 1, and Sanders‐Retzlaff‐Kraff/T [SRK/T]) in patients who underwent pars plana vitrectomy or silicone oil removal combined with cataract surgery. METHODS: In total, 301 eyes from 301 patients who underwent pars plana vitrectomy/silicone oil removal with concomitant cataract surgery were enrolled and divided into the following four groups according to preoperative diagnosis: silicone oil–filled eyes after pars plana vitrectomy, epiretinal membrane, primary retinal detachment, and macular hole. RESULTS: Barrett Universal II exhibited the smallest mean absolute error (0.65 diopters [D]) and median absolute error (0.39 D) in total. In patients with primary retinal detachment, each formula exhibited the worst refractive outcomes in diverse vitreoretinal pathologies (P < 0.01), and no difference in accuracy between the seven formulas was observed (P = 0.075). For long eyes, the second linear (Wang–Koch 2) version of the Wang–Koch adjustment significantly reduced the median absolute error for Holladay 1 and SRK/T (P < 0.001 and P = 0.019). CONCLUSION: In combined surgery, both new and conventional formulas using the second linear version of the Wang–Koch 2 adjustment demonstrated satisfactory performance, with Barrett Universal II exhibiting the best overall performance. However, in patients with primary retinal detachment, all seven formulas showed less favorable performance. Retina 2023-09 2023-06-05 /pmc/articles/PMC10442118/ /pubmed/37307580 http://dx.doi.org/10.1097/IAE.0000000000003846 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Opthalmic Communications Society, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Study Chen, Xu Zhao, He Xu, Yufei Qin, Zuoxin Ren, Jiayun Wang, Lu Wan, Junli Wang, Ziran Liu, Bo Wu, Nan Liu, Xi Liu, Yong ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title | ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title_full | ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title_fullStr | ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title_full_unstemmed | ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title_short | ACCURACY OF NEW INTRAOCULAR LENS CALCULATION FORMULAE IN EYES UNDERGOING SILICONE OIL REMOVAL/PARS PLANA VITRECTOMY-CATARACT SURGERY |
title_sort | accuracy of new intraocular lens calculation formulae in eyes undergoing silicone oil removal/pars plana vitrectomy-cataract surgery |
topic | Original Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10442118/ https://www.ncbi.nlm.nih.gov/pubmed/37307580 http://dx.doi.org/10.1097/IAE.0000000000003846 |
work_keys_str_mv | AT chenxu accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT zhaohe accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT xuyufei accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT qinzuoxin accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT renjiayun accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT wanglu accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT wanjunli accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT wangziran accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT liubo accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT wunan accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT liuxi accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery AT liuyong accuracyofnewintraocularlenscalculationformulaeineyesundergoingsiliconeoilremovalparsplanavitrectomycataractsurgery |