Cargando…

Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters

BACKGROUND: Virtual wedge (VW) is used in radiotherapy to compensate for missing tissues and create a uniform dose distribution in tissues. According to TECDOC-1583 and technical reports series no. 430, evaluating the dose calculation accuracy is essential for the quality assurance of treatment plan...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeinali, Ahad, Molazadeh, Mikaeil, Ganjgahi, Samaneh, Saberi, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445677/
https://www.ncbi.nlm.nih.gov/pubmed/37622042
http://dx.doi.org/10.4103/jmss.jmss_7_22
_version_ 1785094227606110208
author Zeinali, Ahad
Molazadeh, Mikaeil
Ganjgahi, Samaneh
Saberi, Hassan
author_facet Zeinali, Ahad
Molazadeh, Mikaeil
Ganjgahi, Samaneh
Saberi, Hassan
author_sort Zeinali, Ahad
collection PubMed
description BACKGROUND: Virtual wedge (VW) is used in radiotherapy to compensate for missing tissues and create a uniform dose distribution in tissues. According to TECDOC-1583 and technical reports series no. 430, evaluating the dose calculation accuracy is essential for the quality assurance of treatment planning systems (TPSs). In this study, the dose calculation accuracy of the collapsed cone superposition (CCS) algorithm in the postmastectomy radiotherapy of the chest wall for breast cancer was evaluated by comparing the calculated and measured dose in VW fields. METHODS: Two tangential fields with the typical VW angles were planned using ISOgray TPS in a thorax phantom. The CCS algorithm was used for dose calculation at 6 and 15 MV photon beams. The obtained dose distributions from EBT3 film spaces and TPS were evaluated using the gamma index. RESULTS: The measured and calculated dose values using VW in a heterogeneous medium with different beam energies were in a good agreement with each other (acceptance rate: 88.0%–93.4%). The calculated and measured data did not differ significantly with an increase/decrease in wedge angle. In addition, the results demonstrated that ISOgray overestimated and underestimated the dose of the soft tissue and lung in the planned volume, respectively. CONCLUSIONS: According to the results of gamma index analysis, the calculated dose distribution using VW model with the CCS algorithm in a heterogeneous environment was within acceptable limits.
format Online
Article
Text
id pubmed-10445677
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104456772023-08-24 Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters Zeinali, Ahad Molazadeh, Mikaeil Ganjgahi, Samaneh Saberi, Hassan J Med Signals Sens Original Article BACKGROUND: Virtual wedge (VW) is used in radiotherapy to compensate for missing tissues and create a uniform dose distribution in tissues. According to TECDOC-1583 and technical reports series no. 430, evaluating the dose calculation accuracy is essential for the quality assurance of treatment planning systems (TPSs). In this study, the dose calculation accuracy of the collapsed cone superposition (CCS) algorithm in the postmastectomy radiotherapy of the chest wall for breast cancer was evaluated by comparing the calculated and measured dose in VW fields. METHODS: Two tangential fields with the typical VW angles were planned using ISOgray TPS in a thorax phantom. The CCS algorithm was used for dose calculation at 6 and 15 MV photon beams. The obtained dose distributions from EBT3 film spaces and TPS were evaluated using the gamma index. RESULTS: The measured and calculated dose values using VW in a heterogeneous medium with different beam energies were in a good agreement with each other (acceptance rate: 88.0%–93.4%). The calculated and measured data did not differ significantly with an increase/decrease in wedge angle. In addition, the results demonstrated that ISOgray overestimated and underestimated the dose of the soft tissue and lung in the planned volume, respectively. CONCLUSIONS: According to the results of gamma index analysis, the calculated dose distribution using VW model with the CCS algorithm in a heterogeneous environment was within acceptable limits. Wolters Kluwer - Medknow 2023-07-12 /pmc/articles/PMC10445677/ /pubmed/37622042 http://dx.doi.org/10.4103/jmss.jmss_7_22 Text en Copyright: © 2023 Journal of Medical Signals & Sensors https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Zeinali, Ahad
Molazadeh, Mikaeil
Ganjgahi, Samaneh
Saberi, Hassan
Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title_full Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title_fullStr Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title_full_unstemmed Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title_short Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
title_sort collapsed cone superposition algorithm validation for chest wall tangential fields using virtual wedge filters
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445677/
https://www.ncbi.nlm.nih.gov/pubmed/37622042
http://dx.doi.org/10.4103/jmss.jmss_7_22
work_keys_str_mv AT zeinaliahad collapsedconesuperpositionalgorithmvalidationforchestwalltangentialfieldsusingvirtualwedgefilters
AT molazadehmikaeil collapsedconesuperpositionalgorithmvalidationforchestwalltangentialfieldsusingvirtualwedgefilters
AT ganjgahisamaneh collapsedconesuperpositionalgorithmvalidationforchestwalltangentialfieldsusingvirtualwedgefilters
AT saberihassan collapsedconesuperpositionalgorithmvalidationforchestwalltangentialfieldsusingvirtualwedgefilters