Cargando…

Direct oligonucleotide sequencing with nanopores

Third-generation DNA sequencing has enabled sequencing of long, unamplified DNA fragments with minimal steps. Direct sequencing of ssDNA or RNA gives valuable insights like base-level modifications, phosphoramidite synthesis yield estimates and strand quality analysis, without the need to add the co...

Descripción completa

Detalles Bibliográficos
Autores principales: Chalapati, Sachin, Crosbie, Conor A, Limbachiya, Dixita, Pinnamaneni, Nimesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: F1000 Research Limited 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445935/
https://www.ncbi.nlm.nih.gov/pubmed/37645114
http://dx.doi.org/10.12688/openreseurope.13578.2
_version_ 1785094292447952896
author Chalapati, Sachin
Crosbie, Conor A
Limbachiya, Dixita
Pinnamaneni, Nimesh
author_facet Chalapati, Sachin
Crosbie, Conor A
Limbachiya, Dixita
Pinnamaneni, Nimesh
author_sort Chalapati, Sachin
collection PubMed
description Third-generation DNA sequencing has enabled sequencing of long, unamplified DNA fragments with minimal steps. Direct sequencing of ssDNA or RNA gives valuable insights like base-level modifications, phosphoramidite synthesis yield estimates and strand quality analysis, without the need to add the complimentary strand. Direct sequencing of single-stranded nucleic acid species is challenging as they are non-compatible to the double-stranded sequencing adapters used by manufacturers. The MinION platform from Oxford Nanopore Technologies performs sequencing by passing single-strands of DNA through a layer of biological nanopore sensors; although sequencing is performed on single-strands, the recommended template by the manufacturer is double-stranded. We have identified that the MinION platform can perform sequencing of short, single-strand oligonucleotides directly without amplification or second-strand synthesis by performing a single annealing step before library preparation. Short 5’ phosphorylated oligos when annealed to an adapter sequence can be directly sequenced in the 5' to 3' direction via nanopores. Adapter sequences were designed to bind to the 5’ end of the oligos and to leave a 3’ adenosine overhang after binding to their target. The 3’ adenosine overhang of the adapter and the terminal phosphate makes the 5’ end of the oligo analogous to an end-prepared dsDNA, rendering it compatible with ligation-based library preparation for sequencing. An oligo-pool containing 42,000, 120 nt orthogonal sequences was phosphorylated and sequenced using this method and ~90% of these sequences were recovered with high accuracy using BLAST. In the nanopore raw data, we have identified that empty signals can be wrongly identified as a valid read by the MinION platform and sometimes multiple signals containing several strands can be fused into a single raw sequence file due to segmentation faults in the software. This direct oligonucleotide sequencing method enables novel applications in DNA data storage systems where short oligonucleotides are the primary information carriers.
format Online
Article
Text
id pubmed-10445935
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher F1000 Research Limited
record_format MEDLINE/PubMed
spelling pubmed-104459352023-08-29 Direct oligonucleotide sequencing with nanopores Chalapati, Sachin Crosbie, Conor A Limbachiya, Dixita Pinnamaneni, Nimesh Open Res Eur Method Article Third-generation DNA sequencing has enabled sequencing of long, unamplified DNA fragments with minimal steps. Direct sequencing of ssDNA or RNA gives valuable insights like base-level modifications, phosphoramidite synthesis yield estimates and strand quality analysis, without the need to add the complimentary strand. Direct sequencing of single-stranded nucleic acid species is challenging as they are non-compatible to the double-stranded sequencing adapters used by manufacturers. The MinION platform from Oxford Nanopore Technologies performs sequencing by passing single-strands of DNA through a layer of biological nanopore sensors; although sequencing is performed on single-strands, the recommended template by the manufacturer is double-stranded. We have identified that the MinION platform can perform sequencing of short, single-strand oligonucleotides directly without amplification or second-strand synthesis by performing a single annealing step before library preparation. Short 5’ phosphorylated oligos when annealed to an adapter sequence can be directly sequenced in the 5' to 3' direction via nanopores. Adapter sequences were designed to bind to the 5’ end of the oligos and to leave a 3’ adenosine overhang after binding to their target. The 3’ adenosine overhang of the adapter and the terminal phosphate makes the 5’ end of the oligo analogous to an end-prepared dsDNA, rendering it compatible with ligation-based library preparation for sequencing. An oligo-pool containing 42,000, 120 nt orthogonal sequences was phosphorylated and sequenced using this method and ~90% of these sequences were recovered with high accuracy using BLAST. In the nanopore raw data, we have identified that empty signals can be wrongly identified as a valid read by the MinION platform and sometimes multiple signals containing several strands can be fused into a single raw sequence file due to segmentation faults in the software. This direct oligonucleotide sequencing method enables novel applications in DNA data storage systems where short oligonucleotides are the primary information carriers. F1000 Research Limited 2021-08-24 /pmc/articles/PMC10445935/ /pubmed/37645114 http://dx.doi.org/10.12688/openreseurope.13578.2 Text en Copyright: © 2021 Chalapati S et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Method Article
Chalapati, Sachin
Crosbie, Conor A
Limbachiya, Dixita
Pinnamaneni, Nimesh
Direct oligonucleotide sequencing with nanopores
title Direct oligonucleotide sequencing with nanopores
title_full Direct oligonucleotide sequencing with nanopores
title_fullStr Direct oligonucleotide sequencing with nanopores
title_full_unstemmed Direct oligonucleotide sequencing with nanopores
title_short Direct oligonucleotide sequencing with nanopores
title_sort direct oligonucleotide sequencing with nanopores
topic Method Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445935/
https://www.ncbi.nlm.nih.gov/pubmed/37645114
http://dx.doi.org/10.12688/openreseurope.13578.2
work_keys_str_mv AT chalapatisachin directoligonucleotidesequencingwithnanopores
AT crosbieconora directoligonucleotidesequencingwithnanopores
AT limbachiyadixita directoligonucleotidesequencingwithnanopores
AT pinnamaneninimesh directoligonucleotidesequencingwithnanopores