Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation

STUDY DESIGN: A Retrospective Cohort Study. OBJECTIVE: To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conve...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang Hyo, Park, Jong-Hyeok, Lee, Jong Beom, Lee, Ho Jin, Kim, Il Sup, Hur, Jeong Woo, Hong, Jae Taek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10448084/
https://www.ncbi.nlm.nih.gov/pubmed/35193407
http://dx.doi.org/10.1177/21925682211041965
_version_ 1785094649537363968
author Lee, Sang Hyo
Park, Jong-Hyeok
Lee, Jong Beom
Lee, Ho Jin
Kim, Il Sup
Hur, Jeong Woo
Hong, Jae Taek
author_facet Lee, Sang Hyo
Park, Jong-Hyeok
Lee, Jong Beom
Lee, Ho Jin
Kim, Il Sup
Hur, Jeong Woo
Hong, Jae Taek
author_sort Lee, Sang Hyo
collection PubMed
description STUDY DESIGN: A Retrospective Cohort Study. OBJECTIVE: To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conventional technique. METHODS: This retrospective study was performed on 164 consecutive patients that underwent pedicle-based screw fixation from C2 to C6 between January 2013 and August 2020. Surgery was performed without intraoperative Doppler sonography in 84 cases (the Control group) or with intraoperative Doppler sonography in 80 cases (the Doppler group). Proper positioning of pedicle screws was graded, and the incidences of VA injury and screw breach in the Control and Doppler groups were compared. RESULTS: Three hundred and ninety-nine screws were placed in the 164 patients (Doppler, 186 screws; Control, 213 screws). The percentages of well-positioned screws in the two groups were significantly different (Doppler, 97.8%; Control, 85.0%). There were two cases of VA injury in the Control group, an incidence of 2.4%, but no case in the Doppler group. CONCLUSION: Doppler sonography can be used intraoperatively to help guide the trajectory of the cervical pedicle screw insertion. It can detect the VA inside the screw trajectory and may reduce the risk of VA injury during cervical pedicle screw fixation.
format Online
Article
Text
id pubmed-10448084
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-104480842023-08-25 Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation Lee, Sang Hyo Park, Jong-Hyeok Lee, Jong Beom Lee, Ho Jin Kim, Il Sup Hur, Jeong Woo Hong, Jae Taek Global Spine J Original Articles STUDY DESIGN: A Retrospective Cohort Study. OBJECTIVE: To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conventional technique. METHODS: This retrospective study was performed on 164 consecutive patients that underwent pedicle-based screw fixation from C2 to C6 between January 2013 and August 2020. Surgery was performed without intraoperative Doppler sonography in 84 cases (the Control group) or with intraoperative Doppler sonography in 80 cases (the Doppler group). Proper positioning of pedicle screws was graded, and the incidences of VA injury and screw breach in the Control and Doppler groups were compared. RESULTS: Three hundred and ninety-nine screws were placed in the 164 patients (Doppler, 186 screws; Control, 213 screws). The percentages of well-positioned screws in the two groups were significantly different (Doppler, 97.8%; Control, 85.0%). There were two cases of VA injury in the Control group, an incidence of 2.4%, but no case in the Doppler group. CONCLUSION: Doppler sonography can be used intraoperatively to help guide the trajectory of the cervical pedicle screw insertion. It can detect the VA inside the screw trajectory and may reduce the risk of VA injury during cervical pedicle screw fixation. SAGE Publications 2022-02-22 2023-07 /pmc/articles/PMC10448084/ /pubmed/35193407 http://dx.doi.org/10.1177/21925682211041965 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Lee, Sang Hyo
Park, Jong-Hyeok
Lee, Jong Beom
Lee, Ho Jin
Kim, Il Sup
Hur, Jeong Woo
Hong, Jae Taek
Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title_full Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title_fullStr Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title_full_unstemmed Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title_short Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation—A Retrospective Comparison with Conventional Pedicle Screw Implantation
title_sort safety and efficacy of intraoperative doppler sonography-assisted cervical pedicle screw fixation—a retrospective comparison with conventional pedicle screw implantation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10448084/
https://www.ncbi.nlm.nih.gov/pubmed/35193407
http://dx.doi.org/10.1177/21925682211041965
work_keys_str_mv AT leesanghyo safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT parkjonghyeok safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT leejongbeom safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT leehojin safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT kimilsup safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT hurjeongwoo safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation
AT hongjaetaek safetyandefficacyofintraoperativedopplersonographyassistedcervicalpediclescrewfixationaretrospectivecomparisonwithconventionalpediclescrewimplantation