Cargando…
Comparison of the performance of currently used estimated glomerular filtration rate equations with 24-hour urine creatinine clearance: sample analysis of randomised controlled trial participants
OBJECTIVE: There are several equations for estimating the glomerular filtration rate (GFR), and each method has its limitations. We compared various estimated GFR (eGFR) equations with 24 hours urine creatinine clearance (24u-CCr). DESIGN: Sample analysis of randomised controlled trial participants....
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450128/ https://www.ncbi.nlm.nih.gov/pubmed/37612109 http://dx.doi.org/10.1136/bmjopen-2022-067398 |
Sumario: | OBJECTIVE: There are several equations for estimating the glomerular filtration rate (GFR), and each method has its limitations. We compared various estimated GFR (eGFR) equations with 24 hours urine creatinine clearance (24u-CCr). DESIGN: Sample analysis of randomised controlled trial participants. SETTING AND PARTICIPANTS: We compared the mean 24u-CCr values measured 2–3 times for 211 patients with eGFR values calculated using the following equations: isotope dilution mass spectrometry-Modification of Diet in Renal Disease (IDMS-MDRD) equation, Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equation, equations for Koreans (KOR-IDMS-MDRD and KOR-CKD-EPI) and full age spectrum equation. OUTCOME MEASURES: Performance of various creatinine-based eGFR equations, including those with Korean coefficients, compared with the results of the 24u-CCr. RESULTS: IDMS-MDRD showed the best overall correlation with the 24u-CCr (R=0.949, p<0.001), and KOR-CKD-EPI showed the best agreement in terms of the intraclass correlation coefficient (ICC, 0.969, 95% CI 0.959 to 0.976, p<0.001). In subgroup analysis, IDMS-MDRD-GFR showed the highest ICCs in CKD stages 1 and 3 (ICC 0.872 in stage 1 and 0.927 in CKD stage 3, all p<0.001). KOR-CKD-EPI showed the highest ICC in CKD stage 2 (ICC 0.854, p<0.001). Overall, the accuracy of CKD-EPI (2021) was the highest at P15 (15%) and P30 (30%) (P15: 65.4 and P30: 97.6). In addition, CKD-EPI (2021) showed the highest P30 accuracy in CKD stage 1 (98.7), whereas KOR-IDMS-MDRD showed the highest P30 accuracy in CKD stages 2 and 3 (98.8 and 98.2, respectively). CONCLUSIONS: The IDMS-MDRD equation showed the best correlation and overall good agreement with the 24u-CCr; however, the accuracy was low. The most accurate measurements were obtained using the CKD-EPI (2021) equation in CKD stage 1 and the KOR-IDMS-MDRD equation in CKD stages 2–3; nevertheless, the CKD-EPI (2021) equation showed the best overall accuracy. TRIAL REGISTRATION NUMBER: NCT01552954. |
---|