Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
BACKGROUND: Telemedicine support virtual consultations and evaluations in hand surgery for patients in remote areas during the COVID-19 era. However, traditional physical examination is challenging in telemedicine and it is inconvenient to manually measure the hand range of motion (ROM) from images...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450288/ https://www.ncbi.nlm.nih.gov/pubmed/36721870 http://dx.doi.org/10.1177/00368504231152740 |
Sumario: | BACKGROUND: Telemedicine support virtual consultations and evaluations in hand surgery for patients in remote areas during the COVID-19 era. However, traditional physical examination is challenging in telemedicine and it is inconvenient to manually measure the hand range of motion (ROM) from images or videos. Here, we propose an automatic method using the hand pose estimation technique, aiming to measure the hand ROM from smartphone images. METHODS: Twenty-eight healthy volunteers participated in the study. An eight-hand gestures measurement protocol and the Google MediaPipe Hands were used to analyze images and calculate the ROM automatically. Manual goniometry was also performed according to the guideline of the American Medical Association. The correlation between the automatic and manual methods was analyzed by the intraclass correlation coefficient and Pearson correlation coefficient. The clinical acceptance was testified using Bland-Altman plots. RESULTS: A total of 32 parameters of each hand were measured by both methods, and 1792 measurement results were compared. The mean difference between automatic and manual methods is −2.21 ± 9.29° in the angle measurement and 0.48 ± 0.48 cm in the distance measurement. The intraclass correlation coefficient of 75% of parameters was higher than 0.75, the Pearson correlation coefficient of 84% of parameters was over 0.6, and 40.6% of parameters reached well-accepted clinical agreements. CONCLUSIONS: The proposed method provides a helpful protocol for automatic hand ROM measurement based on smartphone images and the MediaPipe Hands pose estimation technique. The automatic measurement is acceptable and comparable with existing methods, showing a possible application in the telemedicine examination of hand surgery. |
---|