Cargando…

Automatic range of motion measurement via smartphone images for telemedicine examination of the hand

BACKGROUND: Telemedicine support virtual consultations and evaluations in hand surgery for patients in remote areas during the COVID-19 era. However, traditional physical examination is challenging in telemedicine and it is inconvenient to manually measure the hand range of motion (ROM) from images...

Descripción completa

Detalles Bibliográficos
Autores principales: Gu, Fanbin, Fan, Jingyuan, Wang, Zhaoyang, Liu, Xiaolin, Yang, Jiantao, Zhu, Qingtang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450288/
https://www.ncbi.nlm.nih.gov/pubmed/36721870
http://dx.doi.org/10.1177/00368504231152740
_version_ 1785095163649982464
author Gu, Fanbin
Fan, Jingyuan
Wang, Zhaoyang
Liu, Xiaolin
Yang, Jiantao
Zhu, Qingtang
author_facet Gu, Fanbin
Fan, Jingyuan
Wang, Zhaoyang
Liu, Xiaolin
Yang, Jiantao
Zhu, Qingtang
author_sort Gu, Fanbin
collection PubMed
description BACKGROUND: Telemedicine support virtual consultations and evaluations in hand surgery for patients in remote areas during the COVID-19 era. However, traditional physical examination is challenging in telemedicine and it is inconvenient to manually measure the hand range of motion (ROM) from images or videos. Here, we propose an automatic method using the hand pose estimation technique, aiming to measure the hand ROM from smartphone images. METHODS: Twenty-eight healthy volunteers participated in the study. An eight-hand gestures measurement protocol and the Google MediaPipe Hands were used to analyze images and calculate the ROM automatically. Manual goniometry was also performed according to the guideline of the American Medical Association. The correlation between the automatic and manual methods was analyzed by the intraclass correlation coefficient and Pearson correlation coefficient. The clinical acceptance was testified using Bland-Altman plots. RESULTS: A total of 32 parameters of each hand were measured by both methods, and 1792 measurement results were compared. The mean difference between automatic and manual methods is −2.21 ± 9.29° in the angle measurement and 0.48 ± 0.48 cm in the distance measurement. The intraclass correlation coefficient of 75% of parameters was higher than 0.75, the Pearson correlation coefficient of 84% of parameters was over 0.6, and 40.6% of parameters reached well-accepted clinical agreements. CONCLUSIONS: The proposed method provides a helpful protocol for automatic hand ROM measurement based on smartphone images and the MediaPipe Hands pose estimation technique. The automatic measurement is acceptable and comparable with existing methods, showing a possible application in the telemedicine examination of hand surgery.
format Online
Article
Text
id pubmed-10450288
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-104502882023-08-26 Automatic range of motion measurement via smartphone images for telemedicine examination of the hand Gu, Fanbin Fan, Jingyuan Wang, Zhaoyang Liu, Xiaolin Yang, Jiantao Zhu, Qingtang Sci Prog Original Manuscript BACKGROUND: Telemedicine support virtual consultations and evaluations in hand surgery for patients in remote areas during the COVID-19 era. However, traditional physical examination is challenging in telemedicine and it is inconvenient to manually measure the hand range of motion (ROM) from images or videos. Here, we propose an automatic method using the hand pose estimation technique, aiming to measure the hand ROM from smartphone images. METHODS: Twenty-eight healthy volunteers participated in the study. An eight-hand gestures measurement protocol and the Google MediaPipe Hands were used to analyze images and calculate the ROM automatically. Manual goniometry was also performed according to the guideline of the American Medical Association. The correlation between the automatic and manual methods was analyzed by the intraclass correlation coefficient and Pearson correlation coefficient. The clinical acceptance was testified using Bland-Altman plots. RESULTS: A total of 32 parameters of each hand were measured by both methods, and 1792 measurement results were compared. The mean difference between automatic and manual methods is −2.21 ± 9.29° in the angle measurement and 0.48 ± 0.48 cm in the distance measurement. The intraclass correlation coefficient of 75% of parameters was higher than 0.75, the Pearson correlation coefficient of 84% of parameters was over 0.6, and 40.6% of parameters reached well-accepted clinical agreements. CONCLUSIONS: The proposed method provides a helpful protocol for automatic hand ROM measurement based on smartphone images and the MediaPipe Hands pose estimation technique. The automatic measurement is acceptable and comparable with existing methods, showing a possible application in the telemedicine examination of hand surgery. SAGE Publications 2023-01-31 /pmc/articles/PMC10450288/ /pubmed/36721870 http://dx.doi.org/10.1177/00368504231152740 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Manuscript
Gu, Fanbin
Fan, Jingyuan
Wang, Zhaoyang
Liu, Xiaolin
Yang, Jiantao
Zhu, Qingtang
Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title_full Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title_fullStr Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title_full_unstemmed Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title_short Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
title_sort automatic range of motion measurement via smartphone images for telemedicine examination of the hand
topic Original Manuscript
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450288/
https://www.ncbi.nlm.nih.gov/pubmed/36721870
http://dx.doi.org/10.1177/00368504231152740
work_keys_str_mv AT gufanbin automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand
AT fanjingyuan automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand
AT wangzhaoyang automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand
AT liuxiaolin automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand
AT yangjiantao automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand
AT zhuqingtang automaticrangeofmotionmeasurementviasmartphoneimagesfortelemedicineexaminationofthehand