Cargando…
Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report
CASE SUMMARY: A patient who underwent mechanical aortic and mitral valve replacement developed three paravalvular leaks 10 months later. We located the tracks by puncturing the apex cordis under transoesophageal echocardiography guidance alone and puncturing the femoral artery guided by fluoroscopy....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450597/ https://www.ncbi.nlm.nih.gov/pubmed/34851207 http://dx.doi.org/10.1177/00368504211058554 |
_version_ | 1785095236646600704 |
---|---|
author | Yi, Kang Ding, Fang-Hui You, Tao Li, Hong-Xin Xu, Jian-Guo Hou, Xiao-Dong Wang, Xin-Kuan Zhang, Xin |
author_facet | Yi, Kang Ding, Fang-Hui You, Tao Li, Hong-Xin Xu, Jian-Guo Hou, Xiao-Dong Wang, Xin-Kuan Zhang, Xin |
author_sort | Yi, Kang |
collection | PubMed |
description | CASE SUMMARY: A patient who underwent mechanical aortic and mitral valve replacement developed three paravalvular leaks 10 months later. We located the tracks by puncturing the apex cordis under transoesophageal echocardiography guidance alone and puncturing the femoral artery guided by fluoroscopy. Three paravalvular leaks were occluded with a hybridization method simultaneously. The patient was followed up for 24 months and maintained a good condition. CONCLUSION: Multiple paravalvular leaks after double valve replacement can be occluded in patients by the use of different approaches under echocardiographic guidance alone. |
format | Online Article Text |
id | pubmed-10450597 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-104505972023-08-26 Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report Yi, Kang Ding, Fang-Hui You, Tao Li, Hong-Xin Xu, Jian-Guo Hou, Xiao-Dong Wang, Xin-Kuan Zhang, Xin Sci Prog Case Report CASE SUMMARY: A patient who underwent mechanical aortic and mitral valve replacement developed three paravalvular leaks 10 months later. We located the tracks by puncturing the apex cordis under transoesophageal echocardiography guidance alone and puncturing the femoral artery guided by fluoroscopy. Three paravalvular leaks were occluded with a hybridization method simultaneously. The patient was followed up for 24 months and maintained a good condition. CONCLUSION: Multiple paravalvular leaks after double valve replacement can be occluded in patients by the use of different approaches under echocardiographic guidance alone. SAGE Publications 2021-12-01 /pmc/articles/PMC10450597/ /pubmed/34851207 http://dx.doi.org/10.1177/00368504211058554 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Yi, Kang Ding, Fang-Hui You, Tao Li, Hong-Xin Xu, Jian-Guo Hou, Xiao-Dong Wang, Xin-Kuan Zhang, Xin Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title | Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title_full | Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title_fullStr | Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title_full_unstemmed | Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title_short | Transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: A case report |
title_sort | transcatheter closure of multiple paravalvular leaks by a transapical approach under echocardiographic guidance: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450597/ https://www.ncbi.nlm.nih.gov/pubmed/34851207 http://dx.doi.org/10.1177/00368504211058554 |
work_keys_str_mv | AT yikang transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT dingfanghui transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT youtao transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT lihongxin transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT xujianguo transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT houxiaodong transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT wangxinkuan transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport AT zhangxin transcatheterclosureofmultipleparavalvularleaksbyatransapicalapproachunderechocardiographicguidanceacasereport |