Cargando…
Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery
PURPOSE: To assess the utility of a validated wearable device (VWD) in examining preoperative and postoperative sleep patterns and how these data compare to patient-reported outcomes (PROs) after rotator cuff repair (RCR) or total shoulder arthroplasty (TSA). METHODS: Male and female adult patients...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450855/ https://www.ncbi.nlm.nih.gov/pubmed/37636255 http://dx.doi.org/10.1016/j.asmr.2023.100783 |
_version_ | 1785095289658408960 |
---|---|
author | Gadangi, Pranav V. Lambert, Bradley S. Goble, Haley Harris, Joshua D. McCulloch, Patrick C. |
author_facet | Gadangi, Pranav V. Lambert, Bradley S. Goble, Haley Harris, Joshua D. McCulloch, Patrick C. |
author_sort | Gadangi, Pranav V. |
collection | PubMed |
description | PURPOSE: To assess the utility of a validated wearable device (VWD) in examining preoperative and postoperative sleep patterns and how these data compare to patient-reported outcomes (PROs) after rotator cuff repair (RCR) or total shoulder arthroplasty (TSA). METHODS: Male and female adult patients undergoing either RCR or TSA were followed up from 34 days preoperatively to 6 weeks postoperatively. Sleep metrics were collected using a VWD in an unsupervised setting. PROs were assessed using the following validated outcome measures: Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function questionnaire; American Shoulder and Elbow Surgeons self-evaluation questionnaire; visual analog scale assessing pain; and Disabilities of the Arm, Shoulder and Hand questionnaire. Data were analyzed preoperatively and at 2-week intervals postoperatively with χ(2) analysis to evaluate device compliance. Sleep metrics and PROs were evaluated at each interval relative to preoperative values within each surgery type with an analysis of variance repeated on time point. The relation between sleep metrics and PROs was assessed with correlation analysis. RESULTS: A total of 57 patients were included, 37 in the RCR group and 20 in the TSA group. The rate of device compliance in the RCR group decreased from 84% at surgery to 46% by 6 weeks postoperatively (P < .001). Similarly, the rate of device compliance in the TSA group decreased from 81% to 52% (P < .001). Deep sleep decreased in RCR patients at 2 to 4 weeks (decrease by 10.99 ± 3.96 minutes, P = .021) and 4 to 6 weeks postoperatively (decrease by 13.37 ± 4.08 minutes, P = .008). TSA patients showed decreased deep sleep at 0 to 2 weeks postoperatively (decrease by 12.91 ± 5.62 minutes, P = .045) and increased rapid eye movement sleep at 2 to 4 weeks postoperatively (increase by 26.91 ± 10.70 minutes, P = .031). Rapid eye movement sleep in the RCR group and total sleep in the TSA group were positively correlated with more favorable PROs (P < .05). CONCLUSIONS: VWDs allow for monitoring components of sleep that offer insight into potential targets for improving postoperative fatigue, pain, and overall recovery after shoulder surgery. However, population demographic factors and ease of device use are barriers to optimized patient compliance during data collection. LEVEL OF EVIDENCE: Level IV, diagnostic case series. |
format | Online Article Text |
id | pubmed-10450855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104508552023-08-26 Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery Gadangi, Pranav V. Lambert, Bradley S. Goble, Haley Harris, Joshua D. McCulloch, Patrick C. Arthrosc Sports Med Rehabil Original Article PURPOSE: To assess the utility of a validated wearable device (VWD) in examining preoperative and postoperative sleep patterns and how these data compare to patient-reported outcomes (PROs) after rotator cuff repair (RCR) or total shoulder arthroplasty (TSA). METHODS: Male and female adult patients undergoing either RCR or TSA were followed up from 34 days preoperatively to 6 weeks postoperatively. Sleep metrics were collected using a VWD in an unsupervised setting. PROs were assessed using the following validated outcome measures: Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function questionnaire; American Shoulder and Elbow Surgeons self-evaluation questionnaire; visual analog scale assessing pain; and Disabilities of the Arm, Shoulder and Hand questionnaire. Data were analyzed preoperatively and at 2-week intervals postoperatively with χ(2) analysis to evaluate device compliance. Sleep metrics and PROs were evaluated at each interval relative to preoperative values within each surgery type with an analysis of variance repeated on time point. The relation between sleep metrics and PROs was assessed with correlation analysis. RESULTS: A total of 57 patients were included, 37 in the RCR group and 20 in the TSA group. The rate of device compliance in the RCR group decreased from 84% at surgery to 46% by 6 weeks postoperatively (P < .001). Similarly, the rate of device compliance in the TSA group decreased from 81% to 52% (P < .001). Deep sleep decreased in RCR patients at 2 to 4 weeks (decrease by 10.99 ± 3.96 minutes, P = .021) and 4 to 6 weeks postoperatively (decrease by 13.37 ± 4.08 minutes, P = .008). TSA patients showed decreased deep sleep at 0 to 2 weeks postoperatively (decrease by 12.91 ± 5.62 minutes, P = .045) and increased rapid eye movement sleep at 2 to 4 weeks postoperatively (increase by 26.91 ± 10.70 minutes, P = .031). Rapid eye movement sleep in the RCR group and total sleep in the TSA group were positively correlated with more favorable PROs (P < .05). CONCLUSIONS: VWDs allow for monitoring components of sleep that offer insight into potential targets for improving postoperative fatigue, pain, and overall recovery after shoulder surgery. However, population demographic factors and ease of device use are barriers to optimized patient compliance during data collection. LEVEL OF EVIDENCE: Level IV, diagnostic case series. Elsevier 2023-08-14 /pmc/articles/PMC10450855/ /pubmed/37636255 http://dx.doi.org/10.1016/j.asmr.2023.100783 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Gadangi, Pranav V. Lambert, Bradley S. Goble, Haley Harris, Joshua D. McCulloch, Patrick C. Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title | Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title_full | Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title_fullStr | Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title_full_unstemmed | Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title_short | Validated Wearable Device Shows Acute Postoperative Changes in Sleep Patterns Consistent With Patient-Reported Outcomes and Progressive Decreases in Device Compliance After Shoulder Surgery |
title_sort | validated wearable device shows acute postoperative changes in sleep patterns consistent with patient-reported outcomes and progressive decreases in device compliance after shoulder surgery |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450855/ https://www.ncbi.nlm.nih.gov/pubmed/37636255 http://dx.doi.org/10.1016/j.asmr.2023.100783 |
work_keys_str_mv | AT gadangipranavv validatedwearabledeviceshowsacutepostoperativechangesinsleeppatternsconsistentwithpatientreportedoutcomesandprogressivedecreasesindevicecomplianceaftershouldersurgery AT lambertbradleys validatedwearabledeviceshowsacutepostoperativechangesinsleeppatternsconsistentwithpatientreportedoutcomesandprogressivedecreasesindevicecomplianceaftershouldersurgery AT goblehaley validatedwearabledeviceshowsacutepostoperativechangesinsleeppatternsconsistentwithpatientreportedoutcomesandprogressivedecreasesindevicecomplianceaftershouldersurgery AT harrisjoshuad validatedwearabledeviceshowsacutepostoperativechangesinsleeppatternsconsistentwithpatientreportedoutcomesandprogressivedecreasesindevicecomplianceaftershouldersurgery AT mccullochpatrickc validatedwearabledeviceshowsacutepostoperativechangesinsleeppatternsconsistentwithpatientreportedoutcomesandprogressivedecreasesindevicecomplianceaftershouldersurgery |