Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making m...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450968/ https://www.ncbi.nlm.nih.gov/pubmed/37636478 http://dx.doi.org/10.1016/j.heliyon.2023.e19093 |
_version_ | 1785095321387270144 |
---|---|
author | Shin, Hakjong Kwak, Younghoon Huh, Jung-Ho |
author_facet | Shin, Hakjong Kwak, Younghoon Huh, Jung-Ho |
author_sort | Shin, Hakjong |
collection | PubMed |
description | Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making monitoring difficult. This study proposes a virtual sensor concept to complement the durability of NH(3) physical sensors. The study also conducts a long-term performance validation of a data-driven NH(3) concentration prediction model. Results indicate that the model's prediction performance declines sharply when the data generation pattern inside the livestock facility changes due to changes in outdoor conditions and facility operation. Furthermore, the prediction performance of the model differed depending on the training data period settings when updating the model. Hence, the model needs versioning and update management to respond to the data generation pattern in the livestock facility when operating the NH(3) concentration virtual sensor. The virtual sensor is expected to enhance monitoring and reduce sensor management costs in livestock facilities. |
format | Online Article Text |
id | pubmed-10450968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104509682023-08-26 Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility Shin, Hakjong Kwak, Younghoon Huh, Jung-Ho Heliyon Research Article Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making monitoring difficult. This study proposes a virtual sensor concept to complement the durability of NH(3) physical sensors. The study also conducts a long-term performance validation of a data-driven NH(3) concentration prediction model. Results indicate that the model's prediction performance declines sharply when the data generation pattern inside the livestock facility changes due to changes in outdoor conditions and facility operation. Furthermore, the prediction performance of the model differed depending on the training data period settings when updating the model. Hence, the model needs versioning and update management to respond to the data generation pattern in the livestock facility when operating the NH(3) concentration virtual sensor. The virtual sensor is expected to enhance monitoring and reduce sensor management costs in livestock facilities. Elsevier 2023-08-12 /pmc/articles/PMC10450968/ /pubmed/37636478 http://dx.doi.org/10.1016/j.heliyon.2023.e19093 Text en © 2023 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Shin, Hakjong Kwak, Younghoon Huh, Jung-Ho Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title | Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title_full | Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title_fullStr | Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title_full_unstemmed | Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title_short | Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility |
title_sort | long-term performance validation of nh(3) concentration prediction model for virtual sensor application in livestock facility |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450968/ https://www.ncbi.nlm.nih.gov/pubmed/37636478 http://dx.doi.org/10.1016/j.heliyon.2023.e19093 |
work_keys_str_mv | AT shinhakjong longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility AT kwakyounghoon longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility AT huhjungho longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility |