Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility

Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making m...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Hakjong, Kwak, Younghoon, Huh, Jung-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450968/
https://www.ncbi.nlm.nih.gov/pubmed/37636478
http://dx.doi.org/10.1016/j.heliyon.2023.e19093
_version_ 1785095321387270144
author Shin, Hakjong
Kwak, Younghoon
Huh, Jung-Ho
author_facet Shin, Hakjong
Kwak, Younghoon
Huh, Jung-Ho
author_sort Shin, Hakjong
collection PubMed
description Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making monitoring difficult. This study proposes a virtual sensor concept to complement the durability of NH(3) physical sensors. The study also conducts a long-term performance validation of a data-driven NH(3) concentration prediction model. Results indicate that the model's prediction performance declines sharply when the data generation pattern inside the livestock facility changes due to changes in outdoor conditions and facility operation. Furthermore, the prediction performance of the model differed depending on the training data period settings when updating the model. Hence, the model needs versioning and update management to respond to the data generation pattern in the livestock facility when operating the NH(3) concentration virtual sensor. The virtual sensor is expected to enhance monitoring and reduce sensor management costs in livestock facilities.
format Online
Article
Text
id pubmed-10450968
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104509682023-08-26 Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility Shin, Hakjong Kwak, Younghoon Huh, Jung-Ho Heliyon Research Article Livestock facilities commonly generate NH(3), a hazardous substance that may also harm livestock. Therefore, monitoring of NH(3) concentrations in livestock facilities is necessary to ensure proper control. However, NH(3) is alkaline and toxic, causing corrosion inside detection sensors and making monitoring difficult. This study proposes a virtual sensor concept to complement the durability of NH(3) physical sensors. The study also conducts a long-term performance validation of a data-driven NH(3) concentration prediction model. Results indicate that the model's prediction performance declines sharply when the data generation pattern inside the livestock facility changes due to changes in outdoor conditions and facility operation. Furthermore, the prediction performance of the model differed depending on the training data period settings when updating the model. Hence, the model needs versioning and update management to respond to the data generation pattern in the livestock facility when operating the NH(3) concentration virtual sensor. The virtual sensor is expected to enhance monitoring and reduce sensor management costs in livestock facilities. Elsevier 2023-08-12 /pmc/articles/PMC10450968/ /pubmed/37636478 http://dx.doi.org/10.1016/j.heliyon.2023.e19093 Text en © 2023 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Shin, Hakjong
Kwak, Younghoon
Huh, Jung-Ho
Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title_full Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title_fullStr Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title_full_unstemmed Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title_short Long-term performance validation of NH(3) concentration prediction model for virtual sensor application in livestock facility
title_sort long-term performance validation of nh(3) concentration prediction model for virtual sensor application in livestock facility
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450968/
https://www.ncbi.nlm.nih.gov/pubmed/37636478
http://dx.doi.org/10.1016/j.heliyon.2023.e19093
work_keys_str_mv AT shinhakjong longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility
AT kwakyounghoon longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility
AT huhjungho longtermperformancevalidationofnh3concentrationpredictionmodelforvirtualsensorapplicationinlivestockfacility