Cargando…

High-fidelity mesoscale in-vivo diffusion MRI through gSlider-BUDA and circular EPI with S-LORAKS reconstruction

PURPOSE: To develop a high-fidelity diffusion MRI acquisition and reconstruction framework with reduced echo-train-length for less T(2)* image blurring compared to typical highly accelerated echo-planar imaging (EPI) acquisitions at sub-millimeter isotropic resolution. METHODS: We first proposed a c...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Congyu, Yarach, Uten, Cao, Xiaozhi, Iyer, Siddharth Srinivasan, Wang, Nan, Kim, Tae Hyung, Tian, Qiyuan, Bilgic, Berkin, Kerr, Adam B., Setsompop, Kawin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10451786/
https://www.ncbi.nlm.nih.gov/pubmed/37187364
http://dx.doi.org/10.1016/j.neuroimage.2023.120168
Descripción
Sumario:PURPOSE: To develop a high-fidelity diffusion MRI acquisition and reconstruction framework with reduced echo-train-length for less T(2)* image blurring compared to typical highly accelerated echo-planar imaging (EPI) acquisitions at sub-millimeter isotropic resolution. METHODS: We first proposed a circular-EPI trajectory with partial Fourier sampling on both the readout and phase-encoding directions to minimize the echo-train-length and echo time. We then utilized this trajectory in an interleaved two-shot EPI acquisition with reversed phase-encoding polarity, to aid in the correction of off-resonance-induced image distortions and provide complementary k-space coverage in the missing partial Fourier regions. Using model-based reconstruction with structured low-rank constraint and smooth phase prior, we corrected the shot-to-shot phase variations across the two shots and recover the missing k-space data. Finally, we combined the proposed acquisition/reconstruction framework with an SNR-efficient RF-encoded simultaneous multi-slab technique, termed gSlider, to achieve high-fidelity 720 μm and 500 μm isotropic resolution in-vivo diffusion MRI. RESULTS: Both simulation and in-vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide distortion-corrected diffusion imaging at the mesoscale with markedly reduced T(2)*-blurring. The in-vivo results of 720 μm and 500 μm datasets show high-fidelity diffusion images with reduced image blurring and echo time using the proposed approaches. CONCLUSIONS: The proposed method provides high-quality distortion-corrected diffusion-weighted images with ~40% reduction in the echo-train-length and T(2)* blurring at 500μm-isotropic-resolution compared to standard multi-shot EPI.