Cargando…

A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity

CRISPR/Cas12-based biosensors are emerging tools for diagnostics. However, their application of heterogeneous formats needs the efficient detection of Cas12 activity. We investigated DNA probes attached to the microplate surface and cleaved by Cas12a. Single-stranded (ss) DNA probes (19 variants) an...

Descripción completa

Detalles Bibliográficos
Autores principales: Burkin, Konstantin M., Ivanov, Aleksandr V., Zherdev, Anatoly V., Dzantiev, Boris B., Safenkova, Irina V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452489/
https://www.ncbi.nlm.nih.gov/pubmed/37622910
http://dx.doi.org/10.3390/bios13080824
_version_ 1785095682170814464
author Burkin, Konstantin M.
Ivanov, Aleksandr V.
Zherdev, Anatoly V.
Dzantiev, Boris B.
Safenkova, Irina V.
author_facet Burkin, Konstantin M.
Ivanov, Aleksandr V.
Zherdev, Anatoly V.
Dzantiev, Boris B.
Safenkova, Irina V.
author_sort Burkin, Konstantin M.
collection PubMed
description CRISPR/Cas12-based biosensors are emerging tools for diagnostics. However, their application of heterogeneous formats needs the efficient detection of Cas12 activity. We investigated DNA probes attached to the microplate surface and cleaved by Cas12a. Single-stranded (ss) DNA probes (19 variants) and combined probes with double-stranded (ds) and ssDNA parts (eight variants) were compared. The cleavage efficiency of dsDNA-probes demonstrated a bell-shaped dependence on their length, with a cleavage maximum of 50%. On the other hand, the cleavage efficiency of ssDNA probes increased monotonously, reaching 70%. The most effective ssDNA probes were integrated with fluorescein, antibodies, and peroxidase conjugates as reporters for fluorescent, lateral flow, and chemiluminescent detection. Long ssDNA probes (120–145 nt) proved the best for detecting Cas12a trans-activity for all of the tested variants. We proposed a test system for the detection of the nucleocapsid (N) gene of SARS-CoV-2 based on Cas12 and the ssDNA-probe attached to the microplate surface; its fluorescent limit of detection was 0.86 nM. Being united with pre-amplification using recombinase polymerase, the system reached a detection limit of 0.01 fM, thus confirming the effectiveness of the chosen ssDNA probe for Cas12-based biosensors.
format Online
Article
Text
id pubmed-10452489
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104524892023-08-26 A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity Burkin, Konstantin M. Ivanov, Aleksandr V. Zherdev, Anatoly V. Dzantiev, Boris B. Safenkova, Irina V. Biosensors (Basel) Article CRISPR/Cas12-based biosensors are emerging tools for diagnostics. However, their application of heterogeneous formats needs the efficient detection of Cas12 activity. We investigated DNA probes attached to the microplate surface and cleaved by Cas12a. Single-stranded (ss) DNA probes (19 variants) and combined probes with double-stranded (ds) and ssDNA parts (eight variants) were compared. The cleavage efficiency of dsDNA-probes demonstrated a bell-shaped dependence on their length, with a cleavage maximum of 50%. On the other hand, the cleavage efficiency of ssDNA probes increased monotonously, reaching 70%. The most effective ssDNA probes were integrated with fluorescein, antibodies, and peroxidase conjugates as reporters for fluorescent, lateral flow, and chemiluminescent detection. Long ssDNA probes (120–145 nt) proved the best for detecting Cas12a trans-activity for all of the tested variants. We proposed a test system for the detection of the nucleocapsid (N) gene of SARS-CoV-2 based on Cas12 and the ssDNA-probe attached to the microplate surface; its fluorescent limit of detection was 0.86 nM. Being united with pre-amplification using recombinase polymerase, the system reached a detection limit of 0.01 fM, thus confirming the effectiveness of the chosen ssDNA probe for Cas12-based biosensors. MDPI 2023-08-17 /pmc/articles/PMC10452489/ /pubmed/37622910 http://dx.doi.org/10.3390/bios13080824 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Burkin, Konstantin M.
Ivanov, Aleksandr V.
Zherdev, Anatoly V.
Dzantiev, Boris B.
Safenkova, Irina V.
A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title_full A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title_fullStr A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title_full_unstemmed A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title_short A Critical Study on DNA Probes Attached to Microplate for CRISPR/Cas12 Trans-Cleavage Activity
title_sort critical study on dna probes attached to microplate for crispr/cas12 trans-cleavage activity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452489/
https://www.ncbi.nlm.nih.gov/pubmed/37622910
http://dx.doi.org/10.3390/bios13080824
work_keys_str_mv AT burkinkonstantinm acriticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT ivanovaleksandrv acriticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT zherdevanatolyv acriticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT dzantievborisb acriticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT safenkovairinav acriticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT burkinkonstantinm criticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT ivanovaleksandrv criticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT zherdevanatolyv criticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT dzantievborisb criticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity
AT safenkovairinav criticalstudyondnaprobesattachedtomicroplateforcrisprcas12transcleavageactivity