Cargando…
Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring
Fabrication, characterization and testing of protective biomimetic orthopedic footwear advanced insole materials are introduced. The main objective of this material is to preserve and isolate a set of sensors for the Weight-Bearing Monitoring System (WBMS) device. Twenty-one samples of renewably sou...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452612/ https://www.ncbi.nlm.nih.gov/pubmed/37622939 http://dx.doi.org/10.3390/biomimetics8040334 |
_version_ | 1785095713188741120 |
---|---|
author | Rubtsova, Sofya Dahman, Yaser |
author_facet | Rubtsova, Sofya Dahman, Yaser |
author_sort | Rubtsova, Sofya |
collection | PubMed |
description | Fabrication, characterization and testing of protective biomimetic orthopedic footwear advanced insole materials are introduced. The main objective of this material is to preserve and isolate a set of sensors for the Weight-Bearing Monitoring System (WBMS) device. Twenty-one samples of renewably sourced Polyurethane Foam (PUF) composed of poly(trimethylene ether) glycol (PO(3)G) and unmodified castor oil (CO) were synthesized and evaluated according to predetermined criteria. Response surface methodology of Box—Behnken design was applied to study the effect of the polyols ratio, isocyanate index (II), and blowing agent ratio on the properties (hardness, density) of PUFs. Results showed that CO/PO(3)G/Tolyene Diisocyanate (TDI) PUFs with hardness Shore A 17–22 and density of 0.19–0.25 g/cm(3) demonstrate the required characteristics and can potentially be used as a durable and functional insole material. Phase separation studies have found the presence of well-segregated structures in PUFs having polyols ratio of CO:PO(3)G 1:3 and low II, which further explains their extraordinary elastic properties (400% elongation). Analysis of cushioning performance of PUF signified that five samples have Cushioning Energy (CE) higher than 70 N·mm and Cushioning Factor (CF) in the range of 4–8, hence are recommended for application in WBMS due to superior weight-bearing and pressure-distributing properties. Moreover, the developed formulation undergoes anaerobic soil bacterial degradation and can be categorized as a “green” bio-based material. |
format | Online Article Text |
id | pubmed-10452612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104526122023-08-26 Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring Rubtsova, Sofya Dahman, Yaser Biomimetics (Basel) Article Fabrication, characterization and testing of protective biomimetic orthopedic footwear advanced insole materials are introduced. The main objective of this material is to preserve and isolate a set of sensors for the Weight-Bearing Monitoring System (WBMS) device. Twenty-one samples of renewably sourced Polyurethane Foam (PUF) composed of poly(trimethylene ether) glycol (PO(3)G) and unmodified castor oil (CO) were synthesized and evaluated according to predetermined criteria. Response surface methodology of Box—Behnken design was applied to study the effect of the polyols ratio, isocyanate index (II), and blowing agent ratio on the properties (hardness, density) of PUFs. Results showed that CO/PO(3)G/Tolyene Diisocyanate (TDI) PUFs with hardness Shore A 17–22 and density of 0.19–0.25 g/cm(3) demonstrate the required characteristics and can potentially be used as a durable and functional insole material. Phase separation studies have found the presence of well-segregated structures in PUFs having polyols ratio of CO:PO(3)G 1:3 and low II, which further explains their extraordinary elastic properties (400% elongation). Analysis of cushioning performance of PUF signified that five samples have Cushioning Energy (CE) higher than 70 N·mm and Cushioning Factor (CF) in the range of 4–8, hence are recommended for application in WBMS due to superior weight-bearing and pressure-distributing properties. Moreover, the developed formulation undergoes anaerobic soil bacterial degradation and can be categorized as a “green” bio-based material. MDPI 2023-07-29 /pmc/articles/PMC10452612/ /pubmed/37622939 http://dx.doi.org/10.3390/biomimetics8040334 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rubtsova, Sofya Dahman, Yaser Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title | Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title_full | Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title_fullStr | Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title_full_unstemmed | Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title_short | Biomimetic Orthopedic Footwear Advanced Insole Materials to Be Used in Medical Casts for Weight-Bearing Monitoring |
title_sort | biomimetic orthopedic footwear advanced insole materials to be used in medical casts for weight-bearing monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452612/ https://www.ncbi.nlm.nih.gov/pubmed/37622939 http://dx.doi.org/10.3390/biomimetics8040334 |
work_keys_str_mv | AT rubtsovasofya biomimeticorthopedicfootwearadvancedinsolematerialstobeusedinmedicalcastsforweightbearingmonitoring AT dahmanyaser biomimeticorthopedicfootwearadvancedinsolematerialstobeusedinmedicalcastsforweightbearingmonitoring |