Cargando…

Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study

Air contamination in operating rooms (ORs) depends on the conditions of the room and on activities therein performed. Methodologies of air quality assessment in ORs are often inadequately described in the scientific literature, and the time required for a change in status in air quality is never tak...

Descripción completa

Detalles Bibliográficos
Autores principales: Albertini, Prospero, Mainardi, Pierangela, Bagattini, Maria, Lombardi, Annalisa, Riccio, Patrizia, Ragosta, Maria, Pennino, Francesca, Bruzzese, Dario, Triassi, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10454192/
https://www.ncbi.nlm.nih.gov/pubmed/37623177
http://dx.doi.org/10.3390/ijerph20166592
_version_ 1785096129027768320
author Albertini, Prospero
Mainardi, Pierangela
Bagattini, Maria
Lombardi, Annalisa
Riccio, Patrizia
Ragosta, Maria
Pennino, Francesca
Bruzzese, Dario
Triassi, Maria
author_facet Albertini, Prospero
Mainardi, Pierangela
Bagattini, Maria
Lombardi, Annalisa
Riccio, Patrizia
Ragosta, Maria
Pennino, Francesca
Bruzzese, Dario
Triassi, Maria
author_sort Albertini, Prospero
collection PubMed
description Air contamination in operating rooms (ORs) depends on the conditions of the room and on activities therein performed. Methodologies of air quality assessment in ORs are often inadequately described in the scientific literature, and the time required for a change in status in air quality is never taken into account. The purpose of this study was to determine the influence of the state and the presence of human operators on air quality by implementing a precise measurement protocol that also took into account the time required for changes in the room to affect air pollution. As the main indicators of air pollution, bacterial load and concentration of airborne dust were measured. The results showed that: the use of surgical masks by operators in the OR did not significantly affect bacterial load within a distance of 2 m; keeping OR doors open did not induce a significant increase in bacterial load and of 5 μm particles while 10 μm particles concentration was positively affected; and air pollution measured with open doors was not significantly different from that due to the presence of two staff members, whether or not they were wearing masks. The results clarified the role of some factors on air pollution in ORs.
format Online
Article
Text
id pubmed-10454192
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104541922023-08-26 Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study Albertini, Prospero Mainardi, Pierangela Bagattini, Maria Lombardi, Annalisa Riccio, Patrizia Ragosta, Maria Pennino, Francesca Bruzzese, Dario Triassi, Maria Int J Environ Res Public Health Article Air contamination in operating rooms (ORs) depends on the conditions of the room and on activities therein performed. Methodologies of air quality assessment in ORs are often inadequately described in the scientific literature, and the time required for a change in status in air quality is never taken into account. The purpose of this study was to determine the influence of the state and the presence of human operators on air quality by implementing a precise measurement protocol that also took into account the time required for changes in the room to affect air pollution. As the main indicators of air pollution, bacterial load and concentration of airborne dust were measured. The results showed that: the use of surgical masks by operators in the OR did not significantly affect bacterial load within a distance of 2 m; keeping OR doors open did not induce a significant increase in bacterial load and of 5 μm particles while 10 μm particles concentration was positively affected; and air pollution measured with open doors was not significantly different from that due to the presence of two staff members, whether or not they were wearing masks. The results clarified the role of some factors on air pollution in ORs. MDPI 2023-08-17 /pmc/articles/PMC10454192/ /pubmed/37623177 http://dx.doi.org/10.3390/ijerph20166592 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Albertini, Prospero
Mainardi, Pierangela
Bagattini, Maria
Lombardi, Annalisa
Riccio, Patrizia
Ragosta, Maria
Pennino, Francesca
Bruzzese, Dario
Triassi, Maria
Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title_full Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title_fullStr Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title_full_unstemmed Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title_short Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room: An Experimental Study
title_sort risk influence of some environmental and behavioral factors on air contamination in the operating room: an experimental study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10454192/
https://www.ncbi.nlm.nih.gov/pubmed/37623177
http://dx.doi.org/10.3390/ijerph20166592
work_keys_str_mv AT albertiniprospero riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT mainardipierangela riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT bagattinimaria riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT lombardiannalisa riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT ricciopatrizia riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT ragostamaria riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT penninofrancesca riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT bruzzesedario riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy
AT triassimaria riskinfluenceofsomeenvironmentalandbehavioralfactorsonaircontaminationintheoperatingroomanexperimentalstudy