Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction

Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive...

Descripción completa

Detalles Bibliográficos
Autores principales: Moiduddin, Khaja, Mian, Syed Hammad, Elseufy, Sherif Mohammed, Alkhalefah, Hisham, Ramalingam, Sundar, Sayeed, Abdul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455463/
https://www.ncbi.nlm.nih.gov/pubmed/37623673
http://dx.doi.org/10.3390/jfb14080429
_version_ 1785096457225764864
author Moiduddin, Khaja
Mian, Syed Hammad
Elseufy, Sherif Mohammed
Alkhalefah, Hisham
Ramalingam, Sundar
Sayeed, Abdul
author_facet Moiduddin, Khaja
Mian, Syed Hammad
Elseufy, Sherif Mohammed
Alkhalefah, Hisham
Ramalingam, Sundar
Sayeed, Abdul
author_sort Moiduddin, Khaja
collection PubMed
description Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive option over metal biomaterials in medical uses, but a solid PEEK implant often leads to poor osseointegration and clinical failure. Therefore, the objective of this study is to demonstrate the quantitative assessment of a custom porous PEEK implant for cranial reconstruction and to evaluate its fitting accuracy. The research proposes an efficient process for designing, fabricating, simulating, and inspecting a customized porous PEEK implant. In this study, a CT scan is utilized in conjunction with a mirrored reconstruction technique to produce a skull implant. In order to foster cell proliferation, the implant is modified into a porous structure. The implant’s strength and stability are examined using finite element analysis. Fused filament fabrication (FFF) is utilized to fabricate the porous PEEK implants, and 3D scanning is used to test its fitting accuracy. The results of the biomechanical analysis indicate that the highest stress observed was approximately 61.92 MPa, which is comparatively low when compared with the yield strength and tensile strength of the material. The implant fitting analysis demonstrates that the implant’s variance from the normal skull is less than 0.4436 mm, which is rather low given the delicate anatomy of the area. The results of the study demonstrate the implant’s endurance while also increasing the patient’s cosmetic value.
format Online
Article
Text
id pubmed-10455463
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104554632023-08-26 Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction Moiduddin, Khaja Mian, Syed Hammad Elseufy, Sherif Mohammed Alkhalefah, Hisham Ramalingam, Sundar Sayeed, Abdul J Funct Biomater Article Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive option over metal biomaterials in medical uses, but a solid PEEK implant often leads to poor osseointegration and clinical failure. Therefore, the objective of this study is to demonstrate the quantitative assessment of a custom porous PEEK implant for cranial reconstruction and to evaluate its fitting accuracy. The research proposes an efficient process for designing, fabricating, simulating, and inspecting a customized porous PEEK implant. In this study, a CT scan is utilized in conjunction with a mirrored reconstruction technique to produce a skull implant. In order to foster cell proliferation, the implant is modified into a porous structure. The implant’s strength and stability are examined using finite element analysis. Fused filament fabrication (FFF) is utilized to fabricate the porous PEEK implants, and 3D scanning is used to test its fitting accuracy. The results of the biomechanical analysis indicate that the highest stress observed was approximately 61.92 MPa, which is comparatively low when compared with the yield strength and tensile strength of the material. The implant fitting analysis demonstrates that the implant’s variance from the normal skull is less than 0.4436 mm, which is rather low given the delicate anatomy of the area. The results of the study demonstrate the implant’s endurance while also increasing the patient’s cosmetic value. MDPI 2023-08-17 /pmc/articles/PMC10455463/ /pubmed/37623673 http://dx.doi.org/10.3390/jfb14080429 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moiduddin, Khaja
Mian, Syed Hammad
Elseufy, Sherif Mohammed
Alkhalefah, Hisham
Ramalingam, Sundar
Sayeed, Abdul
Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title_full Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title_fullStr Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title_full_unstemmed Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title_short Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
title_sort polyether-ether-ketone (peek) and its 3d-printed quantitate assessment in cranial reconstruction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455463/
https://www.ncbi.nlm.nih.gov/pubmed/37623673
http://dx.doi.org/10.3390/jfb14080429
work_keys_str_mv AT moiduddinkhaja polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction
AT miansyedhammad polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction
AT elseufysherifmohammed polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction
AT alkhalefahhisham polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction
AT ramalingamsundar polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction
AT sayeedabdul polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction