Cargando…
Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455463/ https://www.ncbi.nlm.nih.gov/pubmed/37623673 http://dx.doi.org/10.3390/jfb14080429 |
_version_ | 1785096457225764864 |
---|---|
author | Moiduddin, Khaja Mian, Syed Hammad Elseufy, Sherif Mohammed Alkhalefah, Hisham Ramalingam, Sundar Sayeed, Abdul |
author_facet | Moiduddin, Khaja Mian, Syed Hammad Elseufy, Sherif Mohammed Alkhalefah, Hisham Ramalingam, Sundar Sayeed, Abdul |
author_sort | Moiduddin, Khaja |
collection | PubMed |
description | Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive option over metal biomaterials in medical uses, but a solid PEEK implant often leads to poor osseointegration and clinical failure. Therefore, the objective of this study is to demonstrate the quantitative assessment of a custom porous PEEK implant for cranial reconstruction and to evaluate its fitting accuracy. The research proposes an efficient process for designing, fabricating, simulating, and inspecting a customized porous PEEK implant. In this study, a CT scan is utilized in conjunction with a mirrored reconstruction technique to produce a skull implant. In order to foster cell proliferation, the implant is modified into a porous structure. The implant’s strength and stability are examined using finite element analysis. Fused filament fabrication (FFF) is utilized to fabricate the porous PEEK implants, and 3D scanning is used to test its fitting accuracy. The results of the biomechanical analysis indicate that the highest stress observed was approximately 61.92 MPa, which is comparatively low when compared with the yield strength and tensile strength of the material. The implant fitting analysis demonstrates that the implant’s variance from the normal skull is less than 0.4436 mm, which is rather low given the delicate anatomy of the area. The results of the study demonstrate the implant’s endurance while also increasing the patient’s cosmetic value. |
format | Online Article Text |
id | pubmed-10455463 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104554632023-08-26 Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction Moiduddin, Khaja Mian, Syed Hammad Elseufy, Sherif Mohammed Alkhalefah, Hisham Ramalingam, Sundar Sayeed, Abdul J Funct Biomater Article Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive option over metal biomaterials in medical uses, but a solid PEEK implant often leads to poor osseointegration and clinical failure. Therefore, the objective of this study is to demonstrate the quantitative assessment of a custom porous PEEK implant for cranial reconstruction and to evaluate its fitting accuracy. The research proposes an efficient process for designing, fabricating, simulating, and inspecting a customized porous PEEK implant. In this study, a CT scan is utilized in conjunction with a mirrored reconstruction technique to produce a skull implant. In order to foster cell proliferation, the implant is modified into a porous structure. The implant’s strength and stability are examined using finite element analysis. Fused filament fabrication (FFF) is utilized to fabricate the porous PEEK implants, and 3D scanning is used to test its fitting accuracy. The results of the biomechanical analysis indicate that the highest stress observed was approximately 61.92 MPa, which is comparatively low when compared with the yield strength and tensile strength of the material. The implant fitting analysis demonstrates that the implant’s variance from the normal skull is less than 0.4436 mm, which is rather low given the delicate anatomy of the area. The results of the study demonstrate the implant’s endurance while also increasing the patient’s cosmetic value. MDPI 2023-08-17 /pmc/articles/PMC10455463/ /pubmed/37623673 http://dx.doi.org/10.3390/jfb14080429 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Moiduddin, Khaja Mian, Syed Hammad Elseufy, Sherif Mohammed Alkhalefah, Hisham Ramalingam, Sundar Sayeed, Abdul Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title | Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title_full | Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title_fullStr | Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title_full_unstemmed | Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title_short | Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction |
title_sort | polyether-ether-ketone (peek) and its 3d-printed quantitate assessment in cranial reconstruction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455463/ https://www.ncbi.nlm.nih.gov/pubmed/37623673 http://dx.doi.org/10.3390/jfb14080429 |
work_keys_str_mv | AT moiduddinkhaja polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction AT miansyedhammad polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction AT elseufysherifmohammed polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction AT alkhalefahhisham polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction AT ramalingamsundar polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction AT sayeedabdul polyetheretherketonepeekandits3dprintedquantitateassessmentincranialreconstruction |