Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach

Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Ce...

Descripción completa

Detalles Bibliográficos
Autores principales: Chemla, Denis, Agnoletti, Davide, Jozwiak, Mathieu, Zhang, Yi, Protogerou, Athanase D., Millasseau, Sandrine, Blacher, Jacques
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455683/
https://www.ncbi.nlm.nih.gov/pubmed/37623496
http://dx.doi.org/10.3390/jpm13081244
_version_ 1785096511910051840
author Chemla, Denis
Agnoletti, Davide
Jozwiak, Mathieu
Zhang, Yi
Protogerou, Athanase D.
Millasseau, Sandrine
Blacher, Jacques
author_facet Chemla, Denis
Agnoletti, Davide
Jozwiak, Mathieu
Zhang, Yi
Protogerou, Athanase D.
Millasseau, Sandrine
Blacher, Jacques
author_sort Chemla, Denis
collection PubMed
description Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP(2)/DBP) with cSBP estimated by radial tonometry. Methods. Consecutive patients referred for cardiovascular assessment and prevention were prospectively included. Using applanation tonometry with SphygmoCor device, cSBP was estimated using an inbuilt generalized transfer function derived from radial pressure waveform, which was calibrated to oscillometric brachial SBP and DBP. The time-averaged MBP was calculated from the radial pulse waveform. The minimum acceptable error (DCBP-cSBP) was set at ≤5 (mean) and ≤8 mmHg (SD). Results. We included 160 patients (58 years, 54%men). The cSBP was 123.1 ± 18.3 mmHg (range 86–181 mmHg). The (DCBP-cSBP) error was −1.4 ± 4.9 mmHg. There was a linear relationship between cSBP and DCBP (R(2) = 0.93). Forty-seven patients (29%) had cSBP values ≥ 130 mmHg, and a DCBP value > 126 mmHg exhibited a sensitivity of 91.5% and specificity of 94.7% in discriminating this threshold (Youden index = 0.86; AUC = 0.965). Conclusions. Using the DCBP formula, radial tonometry allows for the robust estimation of cSBP without the need for a generalized transfer function. This finding may have implications for risk stratification.
format Online
Article
Text
id pubmed-10455683
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104556832023-08-26 Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach Chemla, Denis Agnoletti, Davide Jozwiak, Mathieu Zhang, Yi Protogerou, Athanase D. Millasseau, Sandrine Blacher, Jacques J Pers Med Article Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP(2)/DBP) with cSBP estimated by radial tonometry. Methods. Consecutive patients referred for cardiovascular assessment and prevention were prospectively included. Using applanation tonometry with SphygmoCor device, cSBP was estimated using an inbuilt generalized transfer function derived from radial pressure waveform, which was calibrated to oscillometric brachial SBP and DBP. The time-averaged MBP was calculated from the radial pulse waveform. The minimum acceptable error (DCBP-cSBP) was set at ≤5 (mean) and ≤8 mmHg (SD). Results. We included 160 patients (58 years, 54%men). The cSBP was 123.1 ± 18.3 mmHg (range 86–181 mmHg). The (DCBP-cSBP) error was −1.4 ± 4.9 mmHg. There was a linear relationship between cSBP and DCBP (R(2) = 0.93). Forty-seven patients (29%) had cSBP values ≥ 130 mmHg, and a DCBP value > 126 mmHg exhibited a sensitivity of 91.5% and specificity of 94.7% in discriminating this threshold (Youden index = 0.86; AUC = 0.965). Conclusions. Using the DCBP formula, radial tonometry allows for the robust estimation of cSBP without the need for a generalized transfer function. This finding may have implications for risk stratification. MDPI 2023-08-10 /pmc/articles/PMC10455683/ /pubmed/37623496 http://dx.doi.org/10.3390/jpm13081244 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chemla, Denis
Agnoletti, Davide
Jozwiak, Mathieu
Zhang, Yi
Protogerou, Athanase D.
Millasseau, Sandrine
Blacher, Jacques
Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title_full Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title_fullStr Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title_full_unstemmed Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title_short Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
title_sort non-invasive estimation of central systolic blood pressure by radial tonometry: a simplified approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455683/
https://www.ncbi.nlm.nih.gov/pubmed/37623496
http://dx.doi.org/10.3390/jpm13081244
work_keys_str_mv AT chemladenis noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT agnolettidavide noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT jozwiakmathieu noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT zhangyi noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT protogerouathanased noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT millasseausandrine noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach
AT blacherjacques noninvasiveestimationofcentralsystolicbloodpressurebyradialtonometryasimplifiedapproach