Cargando…

Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience

Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DS...

Descripción completa

Detalles Bibliográficos
Autores principales: Yildirim, Abdullah, Genc, Omer, Pacaci, Emre, Sen, Omer, Kurt, Ibrahim Halil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455755/
https://www.ncbi.nlm.nih.gov/pubmed/37629415
http://dx.doi.org/10.3390/jcm12165373
_version_ 1785096529088872448
author Yildirim, Abdullah
Genc, Omer
Pacaci, Emre
Sen, Omer
Kurt, Ibrahim Halil
author_facet Yildirim, Abdullah
Genc, Omer
Pacaci, Emre
Sen, Omer
Kurt, Ibrahim Halil
author_sort Yildirim, Abdullah
collection PubMed
description Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results.
format Online
Article
Text
id pubmed-10455755
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104557552023-08-26 Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience Yildirim, Abdullah Genc, Omer Pacaci, Emre Sen, Omer Kurt, Ibrahim Halil J Clin Med Article Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results. MDPI 2023-08-18 /pmc/articles/PMC10455755/ /pubmed/37629415 http://dx.doi.org/10.3390/jcm12165373 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yildirim, Abdullah
Genc, Omer
Pacaci, Emre
Sen, Omer
Kurt, Ibrahim Halil
Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title_full Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title_fullStr Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title_full_unstemmed Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title_short Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
title_sort real-life performance and clinical outcomes of portico transcatheter aortic valve with flexnav delivery system: one-year data from a single-center experience
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455755/
https://www.ncbi.nlm.nih.gov/pubmed/37629415
http://dx.doi.org/10.3390/jcm12165373
work_keys_str_mv AT yildirimabdullah reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience
AT gencomer reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience
AT pacaciemre reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience
AT senomer reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience
AT kurtibrahimhalil reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience