Cargando…
Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience
Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DS...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455755/ https://www.ncbi.nlm.nih.gov/pubmed/37629415 http://dx.doi.org/10.3390/jcm12165373 |
_version_ | 1785096529088872448 |
---|---|
author | Yildirim, Abdullah Genc, Omer Pacaci, Emre Sen, Omer Kurt, Ibrahim Halil |
author_facet | Yildirim, Abdullah Genc, Omer Pacaci, Emre Sen, Omer Kurt, Ibrahim Halil |
author_sort | Yildirim, Abdullah |
collection | PubMed |
description | Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results. |
format | Online Article Text |
id | pubmed-10455755 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104557552023-08-26 Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience Yildirim, Abdullah Genc, Omer Pacaci, Emre Sen, Omer Kurt, Ibrahim Halil J Clin Med Article Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results. MDPI 2023-08-18 /pmc/articles/PMC10455755/ /pubmed/37629415 http://dx.doi.org/10.3390/jcm12165373 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yildirim, Abdullah Genc, Omer Pacaci, Emre Sen, Omer Kurt, Ibrahim Halil Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title | Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title_full | Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title_fullStr | Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title_full_unstemmed | Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title_short | Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience |
title_sort | real-life performance and clinical outcomes of portico transcatheter aortic valve with flexnav delivery system: one-year data from a single-center experience |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455755/ https://www.ncbi.nlm.nih.gov/pubmed/37629415 http://dx.doi.org/10.3390/jcm12165373 |
work_keys_str_mv | AT yildirimabdullah reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience AT gencomer reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience AT pacaciemre reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience AT senomer reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience AT kurtibrahimhalil reallifeperformanceandclinicaloutcomesofporticotranscatheteraorticvalvewithflexnavdeliverysystemoneyeardatafromasinglecenterexperience |