Cargando…

Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files

AIM: To compare cyclic fatigue resistance and bending for three different nickel-titanium (NiTi) rotary files. MATERIALS AND METHODS: A sample of 90 NiTi instruments size (25.06) was divided into three groups with 30 files in each: Race Evo files (FKG Dentaire, Switzerland); Tia Tornado Blue files (...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramadan, Farah, AbuMostafa, Ammar, Alharith, Dalia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456180/
https://www.ncbi.nlm.nih.gov/pubmed/37624849
http://dx.doi.org/10.1371/journal.pone.0290744
_version_ 1785096634593443840
author Ramadan, Farah
AbuMostafa, Ammar
Alharith, Dalia
author_facet Ramadan, Farah
AbuMostafa, Ammar
Alharith, Dalia
author_sort Ramadan, Farah
collection PubMed
description AIM: To compare cyclic fatigue resistance and bending for three different nickel-titanium (NiTi) rotary files. MATERIALS AND METHODS: A sample of 90 NiTi instruments size (25.06) was divided into three groups with 30 files in each: Race Evo files (FKG Dentaire, Switzerland); Tia Tornado Blue files (TiaDent Inc., Texas- USA); One Curve files (Micro-Mega, France). Then each group was subdivided into two groups with 15 files in each; a bending test was performed for one group, and a dynamic cyclic fatigue test at body temperature was performed for the other group. Files fractured by cyclic fatigue were randomly picked from all tested groups for Scanning Electron Microscopy (SEM) (Jeol, Tokyo, Japan). In addition, the test included measuring the broken part of the files tested using (Electronic Micrometre Calliper with LCD Screen, Inch and Millimetre Conversion, Adoric- Taiwan). Data were statistically analyzed using a one-way ANOVA with Tukey-HSD post hoc test. RESULTS: It was found that maximum load [gf] was less (meaning more flexible) in the group of Tia Tornado Blue with a statistically significant difference in comparison with Race Evo and One Curve. The number of cycles to fracture (NCF) in the Race Evo group was significantly higher than the groups of One Curve and Tia Tornado Blue. CONCLUSIONS: Within the limitation of the study, it could be concluded that Race Evo files were more resistant to cyclic fatigue fracture and Tia Tornado Blue files were more flexible compared to the other tested files.
format Online
Article
Text
id pubmed-10456180
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-104561802023-08-26 Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files Ramadan, Farah AbuMostafa, Ammar Alharith, Dalia PLoS One Research Article AIM: To compare cyclic fatigue resistance and bending for three different nickel-titanium (NiTi) rotary files. MATERIALS AND METHODS: A sample of 90 NiTi instruments size (25.06) was divided into three groups with 30 files in each: Race Evo files (FKG Dentaire, Switzerland); Tia Tornado Blue files (TiaDent Inc., Texas- USA); One Curve files (Micro-Mega, France). Then each group was subdivided into two groups with 15 files in each; a bending test was performed for one group, and a dynamic cyclic fatigue test at body temperature was performed for the other group. Files fractured by cyclic fatigue were randomly picked from all tested groups for Scanning Electron Microscopy (SEM) (Jeol, Tokyo, Japan). In addition, the test included measuring the broken part of the files tested using (Electronic Micrometre Calliper with LCD Screen, Inch and Millimetre Conversion, Adoric- Taiwan). Data were statistically analyzed using a one-way ANOVA with Tukey-HSD post hoc test. RESULTS: It was found that maximum load [gf] was less (meaning more flexible) in the group of Tia Tornado Blue with a statistically significant difference in comparison with Race Evo and One Curve. The number of cycles to fracture (NCF) in the Race Evo group was significantly higher than the groups of One Curve and Tia Tornado Blue. CONCLUSIONS: Within the limitation of the study, it could be concluded that Race Evo files were more resistant to cyclic fatigue fracture and Tia Tornado Blue files were more flexible compared to the other tested files. Public Library of Science 2023-08-25 /pmc/articles/PMC10456180/ /pubmed/37624849 http://dx.doi.org/10.1371/journal.pone.0290744 Text en © 2023 Ramadan et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ramadan, Farah
AbuMostafa, Ammar
Alharith, Dalia
Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title_full Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title_fullStr Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title_full_unstemmed Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title_short Evaluation of cyclic fatigue and bending test for different Nickle-Titanium files
title_sort evaluation of cyclic fatigue and bending test for different nickle-titanium files
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456180/
https://www.ncbi.nlm.nih.gov/pubmed/37624849
http://dx.doi.org/10.1371/journal.pone.0290744
work_keys_str_mv AT ramadanfarah evaluationofcyclicfatigueandbendingtestfordifferentnickletitaniumfiles
AT abumostafaammar evaluationofcyclicfatigueandbendingtestfordifferentnickletitaniumfiles
AT alharithdalia evaluationofcyclicfatigueandbendingtestfordifferentnickletitaniumfiles