Cargando…

Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva

The development of accessible express methods to determine markers of viral diseases in saliva is currently an actual problem. Novel cross-sensitive sensors based on Donnan potential with bio-comparable perfluorosulfonic acid membranes for the determination of salivary viral markers (N-acetyl-L-meth...

Descripción completa

Detalles Bibliográficos
Autores principales: Parshina, Anna V., Safronova, Ekaterina Yu., Novikova, Svetlana A., Stretton, Nastasia, Yelnikova, Anastasia S., Zhuchkov, Timur R., Bobreshova, Olga V., Yaroslavtsev, Andrey B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456743/
https://www.ncbi.nlm.nih.gov/pubmed/37623762
http://dx.doi.org/10.3390/membranes13080701
_version_ 1785096772518936576
author Parshina, Anna V.
Safronova, Ekaterina Yu.
Novikova, Svetlana A.
Stretton, Nastasia
Yelnikova, Anastasia S.
Zhuchkov, Timur R.
Bobreshova, Olga V.
Yaroslavtsev, Andrey B.
author_facet Parshina, Anna V.
Safronova, Ekaterina Yu.
Novikova, Svetlana A.
Stretton, Nastasia
Yelnikova, Anastasia S.
Zhuchkov, Timur R.
Bobreshova, Olga V.
Yaroslavtsev, Andrey B.
author_sort Parshina, Anna V.
collection PubMed
description The development of accessible express methods to determine markers of viral diseases in saliva is currently an actual problem. Novel cross-sensitive sensors based on Donnan potential with bio-comparable perfluorosulfonic acid membranes for the determination of salivary viral markers (N-acetyl-L-methionine, L-carnitine, and L-lysine) were proposed. Membranes were formed by casting from dispersions of Nafion or Aquivion in N-methyl-2-pyrollidone or in a mixture of isopropyl alcohol and water. The influence of the polymer equivalent weight and the nature of dispersing liquid on water uptake, ion conductivity, and slope of Donnan potential for the membranes in H(+) and Na(+) form was investigated. The varying of the sorption and transport properties of perfluorosulfonic acid membranes provided a change in the distribution of the sensor sensitivity to N-acetyl-L-methionine, L-carnitine, and L-lysine ions, which was necessary for multisensory system development. The simultaneous determination of three analytes, and the group analysis of them in artificial saliva solutions, was performed. The errors of N-acetyl-L-methionine and L-carnitine determination were 4–12 and 3–11%, respectively. The determination of L-lysine was complicated by its interaction with Ca(2+) ions. The error of the group analysis was no greater than 9%. The reverse character of the viral markers’ sorption by the membranes provided long-term sensor operation.
format Online
Article
Text
id pubmed-10456743
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104567432023-08-26 Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva Parshina, Anna V. Safronova, Ekaterina Yu. Novikova, Svetlana A. Stretton, Nastasia Yelnikova, Anastasia S. Zhuchkov, Timur R. Bobreshova, Olga V. Yaroslavtsev, Andrey B. Membranes (Basel) Article The development of accessible express methods to determine markers of viral diseases in saliva is currently an actual problem. Novel cross-sensitive sensors based on Donnan potential with bio-comparable perfluorosulfonic acid membranes for the determination of salivary viral markers (N-acetyl-L-methionine, L-carnitine, and L-lysine) were proposed. Membranes were formed by casting from dispersions of Nafion or Aquivion in N-methyl-2-pyrollidone or in a mixture of isopropyl alcohol and water. The influence of the polymer equivalent weight and the nature of dispersing liquid on water uptake, ion conductivity, and slope of Donnan potential for the membranes in H(+) and Na(+) form was investigated. The varying of the sorption and transport properties of perfluorosulfonic acid membranes provided a change in the distribution of the sensor sensitivity to N-acetyl-L-methionine, L-carnitine, and L-lysine ions, which was necessary for multisensory system development. The simultaneous determination of three analytes, and the group analysis of them in artificial saliva solutions, was performed. The errors of N-acetyl-L-methionine and L-carnitine determination were 4–12 and 3–11%, respectively. The determination of L-lysine was complicated by its interaction with Ca(2+) ions. The error of the group analysis was no greater than 9%. The reverse character of the viral markers’ sorption by the membranes provided long-term sensor operation. MDPI 2023-07-27 /pmc/articles/PMC10456743/ /pubmed/37623762 http://dx.doi.org/10.3390/membranes13080701 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Parshina, Anna V.
Safronova, Ekaterina Yu.
Novikova, Svetlana A.
Stretton, Nastasia
Yelnikova, Anastasia S.
Zhuchkov, Timur R.
Bobreshova, Olga V.
Yaroslavtsev, Andrey B.
Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title_full Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title_fullStr Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title_full_unstemmed Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title_short Perfluorosulfonic Acid Membranes with Short and Long Side Chains and Their Use in Sensors for the Determination of Markers of Viral Diseases in Saliva
title_sort perfluorosulfonic acid membranes with short and long side chains and their use in sensors for the determination of markers of viral diseases in saliva
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456743/
https://www.ncbi.nlm.nih.gov/pubmed/37623762
http://dx.doi.org/10.3390/membranes13080701
work_keys_str_mv AT parshinaannav perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT safronovaekaterinayu perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT novikovasvetlanaa perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT strettonnastasia perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT yelnikovaanastasias perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT zhuchkovtimurr perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT bobreshovaolgav perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva
AT yaroslavtsevandreyb perfluorosulfonicacidmembraneswithshortandlongsidechainsandtheiruseinsensorsforthedeterminationofmarkersofviraldiseasesinsaliva