Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy

BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (L...

Descripción completa

Detalles Bibliográficos
Autores principales: Rippke, Carolin, Renkamp, C. Katharina, Attieh, Charbel, Schlüter, Fabian, Buchele, Carolin, Debus, Jürgen, Alber, Markus, Klüter, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10457557/
https://www.ncbi.nlm.nih.gov/pubmed/37635846
http://dx.doi.org/10.1016/j.phro.2023.100477
_version_ 1785096961565655040
author Rippke, Carolin
Renkamp, C. Katharina
Attieh, Charbel
Schlüter, Fabian
Buchele, Carolin
Debus, Jürgen
Alber, Markus
Klüter, Sebastian
author_facet Rippke, Carolin
Renkamp, C. Katharina
Attieh, Charbel
Schlüter, Fabian
Buchele, Carolin
Debus, Jürgen
Alber, Markus
Klüter, Sebastian
author_sort Rippke, Carolin
collection PubMed
description BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (LIMCA) method for double stack MLCs. MATERIALS AND METHODS: MLC leaf positions were evaluated from four cardinal angles with test patterns at measurement positions throughout the radiation field on EBT3 radiochromic film for each single stack. The accuracy of the method and repeatability of the results were assessed. The effect of MLC positioning errors was characterized for a measured output factor curve and a clinical patient plan. RESULTS: All positions in the motor step – position calibration file were optimized in the established LIMCA method. The resulting double stack mean accuracy for all angles was 0.2 ± 0.1 mm for X1 (left bank) and 0.2 ± 0.2 mm for X2 (right bank). The accuracy of the leaf position evaluation was 0.2 mm (95% confidence level). The MLC calibration remained stable over four months. Small MLC leaf position errors (e.g. 1.2 mm field size reduction) resulted in important dose errors (−5.8 %) for small quadratic fields of 0.83 × 0.83 cm(2). Single stack position accuracy was essential for highly modulated treatment plans. CONCLUSIONS: LIMCA is a new double stack MLC calibration method that increases treatment accuracy from four angles and for all moving leaves.
format Online
Article
Text
id pubmed-10457557
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104575572023-08-27 Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy Rippke, Carolin Renkamp, C. Katharina Attieh, Charbel Schlüter, Fabian Buchele, Carolin Debus, Jürgen Alber, Markus Klüter, Sebastian Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (LIMCA) method for double stack MLCs. MATERIALS AND METHODS: MLC leaf positions were evaluated from four cardinal angles with test patterns at measurement positions throughout the radiation field on EBT3 radiochromic film for each single stack. The accuracy of the method and repeatability of the results were assessed. The effect of MLC positioning errors was characterized for a measured output factor curve and a clinical patient plan. RESULTS: All positions in the motor step – position calibration file were optimized in the established LIMCA method. The resulting double stack mean accuracy for all angles was 0.2 ± 0.1 mm for X1 (left bank) and 0.2 ± 0.2 mm for X2 (right bank). The accuracy of the leaf position evaluation was 0.2 mm (95% confidence level). The MLC calibration remained stable over four months. Small MLC leaf position errors (e.g. 1.2 mm field size reduction) resulted in important dose errors (−5.8 %) for small quadratic fields of 0.83 × 0.83 cm(2). Single stack position accuracy was essential for highly modulated treatment plans. CONCLUSIONS: LIMCA is a new double stack MLC calibration method that increases treatment accuracy from four angles and for all moving leaves. Elsevier 2023-08-10 /pmc/articles/PMC10457557/ /pubmed/37635846 http://dx.doi.org/10.1016/j.phro.2023.100477 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Rippke, Carolin
Renkamp, C. Katharina
Attieh, Charbel
Schlüter, Fabian
Buchele, Carolin
Debus, Jürgen
Alber, Markus
Klüter, Sebastian
Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title_full Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title_fullStr Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title_full_unstemmed Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title_short Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
title_sort leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10457557/
https://www.ncbi.nlm.nih.gov/pubmed/37635846
http://dx.doi.org/10.1016/j.phro.2023.100477
work_keys_str_mv AT rippkecarolin leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT renkampckatharina leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT attiehcharbel leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT schluterfabian leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT buchelecarolin leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT debusjurgen leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT albermarkus leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy
AT klutersebastian leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy