Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy
BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (L...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10457557/ https://www.ncbi.nlm.nih.gov/pubmed/37635846 http://dx.doi.org/10.1016/j.phro.2023.100477 |
_version_ | 1785096961565655040 |
---|---|
author | Rippke, Carolin Renkamp, C. Katharina Attieh, Charbel Schlüter, Fabian Buchele, Carolin Debus, Jürgen Alber, Markus Klüter, Sebastian |
author_facet | Rippke, Carolin Renkamp, C. Katharina Attieh, Charbel Schlüter, Fabian Buchele, Carolin Debus, Jürgen Alber, Markus Klüter, Sebastian |
author_sort | Rippke, Carolin |
collection | PubMed |
description | BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (LIMCA) method for double stack MLCs. MATERIALS AND METHODS: MLC leaf positions were evaluated from four cardinal angles with test patterns at measurement positions throughout the radiation field on EBT3 radiochromic film for each single stack. The accuracy of the method and repeatability of the results were assessed. The effect of MLC positioning errors was characterized for a measured output factor curve and a clinical patient plan. RESULTS: All positions in the motor step – position calibration file were optimized in the established LIMCA method. The resulting double stack mean accuracy for all angles was 0.2 ± 0.1 mm for X1 (left bank) and 0.2 ± 0.2 mm for X2 (right bank). The accuracy of the leaf position evaluation was 0.2 mm (95% confidence level). The MLC calibration remained stable over four months. Small MLC leaf position errors (e.g. 1.2 mm field size reduction) resulted in important dose errors (−5.8 %) for small quadratic fields of 0.83 × 0.83 cm(2). Single stack position accuracy was essential for highly modulated treatment plans. CONCLUSIONS: LIMCA is a new double stack MLC calibration method that increases treatment accuracy from four angles and for all moving leaves. |
format | Online Article Text |
id | pubmed-10457557 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104575572023-08-27 Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy Rippke, Carolin Renkamp, C. Katharina Attieh, Charbel Schlüter, Fabian Buchele, Carolin Debus, Jürgen Alber, Markus Klüter, Sebastian Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (LIMCA) method for double stack MLCs. MATERIALS AND METHODS: MLC leaf positions were evaluated from four cardinal angles with test patterns at measurement positions throughout the radiation field on EBT3 radiochromic film for each single stack. The accuracy of the method and repeatability of the results were assessed. The effect of MLC positioning errors was characterized for a measured output factor curve and a clinical patient plan. RESULTS: All positions in the motor step – position calibration file were optimized in the established LIMCA method. The resulting double stack mean accuracy for all angles was 0.2 ± 0.1 mm for X1 (left bank) and 0.2 ± 0.2 mm for X2 (right bank). The accuracy of the leaf position evaluation was 0.2 mm (95% confidence level). The MLC calibration remained stable over four months. Small MLC leaf position errors (e.g. 1.2 mm field size reduction) resulted in important dose errors (−5.8 %) for small quadratic fields of 0.83 × 0.83 cm(2). Single stack position accuracy was essential for highly modulated treatment plans. CONCLUSIONS: LIMCA is a new double stack MLC calibration method that increases treatment accuracy from four angles and for all moving leaves. Elsevier 2023-08-10 /pmc/articles/PMC10457557/ /pubmed/37635846 http://dx.doi.org/10.1016/j.phro.2023.100477 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Rippke, Carolin Renkamp, C. Katharina Attieh, Charbel Schlüter, Fabian Buchele, Carolin Debus, Jürgen Alber, Markus Klüter, Sebastian Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title | Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title_full | Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title_fullStr | Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title_full_unstemmed | Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title_short | Leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
title_sort | leaf-individual calibration for a double stack multileaf collimator in photon radiotherapy |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10457557/ https://www.ncbi.nlm.nih.gov/pubmed/37635846 http://dx.doi.org/10.1016/j.phro.2023.100477 |
work_keys_str_mv | AT rippkecarolin leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT renkampckatharina leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT attiehcharbel leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT schluterfabian leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT buchelecarolin leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT debusjurgen leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT albermarkus leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy AT klutersebastian leafindividualcalibrationforadoublestackmultileafcollimatorinphotonradiotherapy |