Cargando…

Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends

The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the...

Descripción completa

Detalles Bibliográficos
Autores principales: Tiwari, Anubhav, Ahmed, Ishfaq A., Gupta, Vijay Kumar, Haldkar, Rakesh Kumar, Parinov, Ivan A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458138/
https://www.ncbi.nlm.nih.gov/pubmed/37630181
http://dx.doi.org/10.3390/mi14081646
_version_ 1785097095453081600
author Tiwari, Anubhav
Ahmed, Ishfaq A.
Gupta, Vijay Kumar
Haldkar, Rakesh Kumar
Parinov, Ivan A.
author_facet Tiwari, Anubhav
Ahmed, Ishfaq A.
Gupta, Vijay Kumar
Haldkar, Rakesh Kumar
Parinov, Ivan A.
author_sort Tiwari, Anubhav
collection PubMed
description The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient’s region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions.
format Online
Article
Text
id pubmed-10458138
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104581382023-08-27 Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends Tiwari, Anubhav Ahmed, Ishfaq A. Gupta, Vijay Kumar Haldkar, Rakesh Kumar Parinov, Ivan A. Micromachines (Basel) Article The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient’s region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions. MDPI 2023-08-20 /pmc/articles/PMC10458138/ /pubmed/37630181 http://dx.doi.org/10.3390/mi14081646 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tiwari, Anubhav
Ahmed, Ishfaq A.
Gupta, Vijay Kumar
Haldkar, Rakesh Kumar
Parinov, Ivan A.
Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title_full Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title_fullStr Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title_full_unstemmed Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title_short Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends
title_sort customised implant for temporomandibular joint: new technique to design and stress analysis to balance the loading at both ends
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458138/
https://www.ncbi.nlm.nih.gov/pubmed/37630181
http://dx.doi.org/10.3390/mi14081646
work_keys_str_mv AT tiwarianubhav customisedimplantfortemporomandibularjointnewtechniquetodesignandstressanalysistobalancetheloadingatbothends
AT ahmedishfaqa customisedimplantfortemporomandibularjointnewtechniquetodesignandstressanalysistobalancetheloadingatbothends
AT guptavijaykumar customisedimplantfortemporomandibularjointnewtechniquetodesignandstressanalysistobalancetheloadingatbothends
AT haldkarrakeshkumar customisedimplantfortemporomandibularjointnewtechniquetodesignandstressanalysistobalancetheloadingatbothends
AT parinovivana customisedimplantfortemporomandibularjointnewtechniquetodesignandstressanalysistobalancetheloadingatbothends