Cargando…

Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2

Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO(2)/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabricatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Meškinis, Šarunas, Gudaitis, Rimantas, Vasiliauskas, Andrius, Guobienė, Asta, Jankauskas, Šarūnas, Stankevič, Voitech, Keršulis, Skirmantas, Stirkė, Arūnas, Andriukonis, Eivydas, Melo, Wanessa, Vertelis, Vilius, Žurauskienė, Nerija
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458353/
https://www.ncbi.nlm.nih.gov/pubmed/37630958
http://dx.doi.org/10.3390/nano13162373
_version_ 1785097146536558592
author Meškinis, Šarunas
Gudaitis, Rimantas
Vasiliauskas, Andrius
Guobienė, Asta
Jankauskas, Šarūnas
Stankevič, Voitech
Keršulis, Skirmantas
Stirkė, Arūnas
Andriukonis, Eivydas
Melo, Wanessa
Vertelis, Vilius
Žurauskienė, Nerija
author_facet Meškinis, Šarunas
Gudaitis, Rimantas
Vasiliauskas, Andrius
Guobienė, Asta
Jankauskas, Šarūnas
Stankevič, Voitech
Keršulis, Skirmantas
Stirkė, Arūnas
Andriukonis, Eivydas
Melo, Wanessa
Vertelis, Vilius
Žurauskienė, Nerija
author_sort Meškinis, Šarunas
collection PubMed
description Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO(2)/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 μg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 μg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics.
format Online
Article
Text
id pubmed-10458353
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104583532023-08-27 Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2 Meškinis, Šarunas Gudaitis, Rimantas Vasiliauskas, Andrius Guobienė, Asta Jankauskas, Šarūnas Stankevič, Voitech Keršulis, Skirmantas Stirkė, Arūnas Andriukonis, Eivydas Melo, Wanessa Vertelis, Vilius Žurauskienė, Nerija Nanomaterials (Basel) Article Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO(2)/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 μg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 μg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics. MDPI 2023-08-18 /pmc/articles/PMC10458353/ /pubmed/37630958 http://dx.doi.org/10.3390/nano13162373 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Meškinis, Šarunas
Gudaitis, Rimantas
Vasiliauskas, Andrius
Guobienė, Asta
Jankauskas, Šarūnas
Stankevič, Voitech
Keršulis, Skirmantas
Stirkė, Arūnas
Andriukonis, Eivydas
Melo, Wanessa
Vertelis, Vilius
Žurauskienė, Nerija
Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title_full Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title_fullStr Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title_full_unstemmed Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title_short Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
title_sort biosensor based on graphene directly grown by mw-pecvd for detection of covid-19 spike (s) protein and its entry receptor ace2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458353/
https://www.ncbi.nlm.nih.gov/pubmed/37630958
http://dx.doi.org/10.3390/nano13162373
work_keys_str_mv AT meskinissarunas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT gudaitisrimantas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT vasiliauskasandrius biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT guobieneasta biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT jankauskassarunas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT stankevicvoitech biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT kersulisskirmantas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT stirkearunas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT andriukoniseivydas biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT melowanessa biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT vertelisvilius biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2
AT zurauskienenerija biosensorbasedongraphenedirectlygrownbymwpecvdfordetectionofcovid19spikesproteinanditsentryreceptorace2