Cargando…
Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor
The comprehension of potentiometric pH sensors with polymeric thin films for new and advanced applications is a constant technological need. The present study aimed to explore the relationship between the sensitivity and correlation coefficient of potentiometric pH sensors and the structure–property...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10459526/ https://www.ncbi.nlm.nih.gov/pubmed/37631510 http://dx.doi.org/10.3390/polym15163450 |
_version_ | 1785097432635277312 |
---|---|
author | Fraga, Vinicius M. Lovi, Isabela T. Abegão, Luis M. G. Mello, Hugo J. N. P. D. |
author_facet | Fraga, Vinicius M. Lovi, Isabela T. Abegão, Luis M. G. Mello, Hugo J. N. P. D. |
author_sort | Fraga, Vinicius M. |
collection | PubMed |
description | The comprehension of potentiometric pH sensors with polymeric thin films for new and advanced applications is a constant technological need. The present study aimed to explore the relationship between the sensitivity and correlation coefficient of potentiometric pH sensors and the structure–property relationship of polyaniline thin films. The effect of the deposition method on the sample’s properties was evaluated. Galvanostatically electrodeposited and spin-coated polyaniline thin films were used as the sensing stage. Samples were electrodeposited with a current density of 0.5 mA/cm(2) for 300, 600, and 1200 s and were spin coated for 60 s with an angular velocity of 500, 1000, and 2000 rpm. The electrodeposited set of films presented higher average sensitivity, 73.4 ± 1.3 mV/pH, compared to the spin-coated set, 59.2 ± 2.5 mV/pH. The electrodeposited films presented higher sensitivity due to their morphology, characterized by a larger roughness and thickness compared to spin-coated ones, favoring the potentiometric response. Also, their oxidation state, evaluated with cyclic voltammetry and UV-VIS spectroscopy, corroborates their sensing performance. The understanding of the structure–property relationship of the polymeric films affecting the pH detection is discussed based on the characteristics of the deposition method used. |
format | Online Article Text |
id | pubmed-10459526 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-104595262023-08-27 Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor Fraga, Vinicius M. Lovi, Isabela T. Abegão, Luis M. G. Mello, Hugo J. N. P. D. Polymers (Basel) Article The comprehension of potentiometric pH sensors with polymeric thin films for new and advanced applications is a constant technological need. The present study aimed to explore the relationship between the sensitivity and correlation coefficient of potentiometric pH sensors and the structure–property relationship of polyaniline thin films. The effect of the deposition method on the sample’s properties was evaluated. Galvanostatically electrodeposited and spin-coated polyaniline thin films were used as the sensing stage. Samples were electrodeposited with a current density of 0.5 mA/cm(2) for 300, 600, and 1200 s and were spin coated for 60 s with an angular velocity of 500, 1000, and 2000 rpm. The electrodeposited set of films presented higher average sensitivity, 73.4 ± 1.3 mV/pH, compared to the spin-coated set, 59.2 ± 2.5 mV/pH. The electrodeposited films presented higher sensitivity due to their morphology, characterized by a larger roughness and thickness compared to spin-coated ones, favoring the potentiometric response. Also, their oxidation state, evaluated with cyclic voltammetry and UV-VIS spectroscopy, corroborates their sensing performance. The understanding of the structure–property relationship of the polymeric films affecting the pH detection is discussed based on the characteristics of the deposition method used. MDPI 2023-08-18 /pmc/articles/PMC10459526/ /pubmed/37631510 http://dx.doi.org/10.3390/polym15163450 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fraga, Vinicius M. Lovi, Isabela T. Abegão, Luis M. G. Mello, Hugo J. N. P. D. Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title | Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title_full | Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title_fullStr | Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title_full_unstemmed | Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title_short | Understanding the Effect of Deposition Technique on the Structure–Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor |
title_sort | understanding the effect of deposition technique on the structure–property relationship of polyaniline thin films applied in potentiometric ph sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10459526/ https://www.ncbi.nlm.nih.gov/pubmed/37631510 http://dx.doi.org/10.3390/polym15163450 |
work_keys_str_mv | AT fragaviniciusm understandingtheeffectofdepositiontechniqueonthestructurepropertyrelationshipofpolyanilinethinfilmsappliedinpotentiometricphsensor AT loviisabelat understandingtheeffectofdepositiontechniqueonthestructurepropertyrelationshipofpolyanilinethinfilmsappliedinpotentiometricphsensor AT abegaoluismg understandingtheeffectofdepositiontechniqueonthestructurepropertyrelationshipofpolyanilinethinfilmsappliedinpotentiometricphsensor AT mellohugojnpd understandingtheeffectofdepositiontechniqueonthestructurepropertyrelationshipofpolyanilinethinfilmsappliedinpotentiometricphsensor |