Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation

PURPOSE: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). METHODS: Ten healthy participants received calf-NMES w...

Descripción completa

Detalles Bibliográficos
Autores principales: Sundström, C., Juthberg, R., Flodin, J., Guo, L., Persson, N.-K., Ackermann, P. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460736/
https://www.ncbi.nlm.nih.gov/pubmed/37145130
http://dx.doi.org/10.1007/s00421-023-05212-5
_version_ 1785097697436368896
author Sundström, C.
Juthberg, R.
Flodin, J.
Guo, L.
Persson, N.-K.
Ackermann, P. W.
author_facet Sundström, C.
Juthberg, R.
Flodin, J.
Guo, L.
Persson, N.-K.
Ackermann, P. W.
author_sort Sundström, C.
collection PubMed
description PURPOSE: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). METHODS: Ten healthy participants received calf-NMES with increasing intensity until plantar flexion (measurement level I = ML I), and an additional mean 4 mA intensity (ML II), utilizing TTE and MPE. PVV was measured with Doppler ultrasound in the popliteal and femoral veins at baseline, ML I and II. Discomfort was assessed with a numerical rating scale (NRS, 0–10). Significance was set to p < 0.05. RESULTS: TTE and MPE both induced significant increases in PVV from baseline to ML I and significantly higher increases to ML II, in both the popliteal and femoral veins (all p < 0.001). The popliteal increases of PVV from baseline to both ML I and II were significantly higher with TTE versus MPE (p < 0.05). The femoral increases of PVV from baseline to both ML I and II were not significantly different between TTE and MPE. TTE versus MPE resulted at ML I in higher mA and NRS (p < 0.001), and at ML II in higher mA (p = 0.005) while NRS was not significantly different. CONCLUSION: TTE integrated in a sock produces intensity-dependent increases of popliteal and femoral hemodynamics comparable to MPE, but results in more discomfort at plantar flexion due to higher current required. TTE exhibits in the popliteal vein higher increases of PVV compared to MPE. TRIAL REGISTRATION: Trial_ID: ISRCTN49260430. Date: 11/01/2022. Retrospectively registered.
format Online
Article
Text
id pubmed-10460736
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-104607362023-08-29 Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation Sundström, C. Juthberg, R. Flodin, J. Guo, L. Persson, N.-K. Ackermann, P. W. Eur J Appl Physiol Original Article PURPOSE: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). METHODS: Ten healthy participants received calf-NMES with increasing intensity until plantar flexion (measurement level I = ML I), and an additional mean 4 mA intensity (ML II), utilizing TTE and MPE. PVV was measured with Doppler ultrasound in the popliteal and femoral veins at baseline, ML I and II. Discomfort was assessed with a numerical rating scale (NRS, 0–10). Significance was set to p < 0.05. RESULTS: TTE and MPE both induced significant increases in PVV from baseline to ML I and significantly higher increases to ML II, in both the popliteal and femoral veins (all p < 0.001). The popliteal increases of PVV from baseline to both ML I and II were significantly higher with TTE versus MPE (p < 0.05). The femoral increases of PVV from baseline to both ML I and II were not significantly different between TTE and MPE. TTE versus MPE resulted at ML I in higher mA and NRS (p < 0.001), and at ML II in higher mA (p = 0.005) while NRS was not significantly different. CONCLUSION: TTE integrated in a sock produces intensity-dependent increases of popliteal and femoral hemodynamics comparable to MPE, but results in more discomfort at plantar flexion due to higher current required. TTE exhibits in the popliteal vein higher increases of PVV compared to MPE. TRIAL REGISTRATION: Trial_ID: ISRCTN49260430. Date: 11/01/2022. Retrospectively registered. Springer Berlin Heidelberg 2023-05-05 2023 /pmc/articles/PMC10460736/ /pubmed/37145130 http://dx.doi.org/10.1007/s00421-023-05212-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Sundström, C.
Juthberg, R.
Flodin, J.
Guo, L.
Persson, N.-K.
Ackermann, P. W.
Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title_full Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title_fullStr Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title_full_unstemmed Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title_short Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
title_sort effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460736/
https://www.ncbi.nlm.nih.gov/pubmed/37145130
http://dx.doi.org/10.1007/s00421-023-05212-5
work_keys_str_mv AT sundstromc effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation
AT juthbergr effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation
AT flodinj effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation
AT guol effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation
AT perssonnk effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation
AT ackermannpw effectsonhemodynamicenhancementanddiscomfortofanewtextileelectrodeintegratedinasockduringcalfneuromuscularelectricalstimulation