Cargando…
Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience
OBJECTIVES: Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators. METHODS: Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minim...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461289/ https://www.ncbi.nlm.nih.gov/pubmed/37449675 http://dx.doi.org/10.1259/bjr.20220733 |
_version_ | 1785097818231275520 |
---|---|
author | Annoni, Andrea Daniele Mancini, Maria Elisabetta Carlicchi, Eleonora Belmonte, Marta Formenti, Alberto Mushtaq, Saima Marchetti, Francesca Cilia, Francesco Baggiano, Andrea Fusini, Laura Bonomi, Alice Gennari, Marco Montorsi, Piero Pepi, Mauro Pontone, Gianluca |
author_facet | Annoni, Andrea Daniele Mancini, Maria Elisabetta Carlicchi, Eleonora Belmonte, Marta Formenti, Alberto Mushtaq, Saima Marchetti, Francesca Cilia, Francesco Baggiano, Andrea Fusini, Laura Bonomi, Alice Gennari, Marco Montorsi, Piero Pepi, Mauro Pontone, Gianluca |
author_sort | Annoni, Andrea Daniele |
collection | PubMed |
description | OBJECTIVES: Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators. METHODS: Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with >5 years and 1 year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared. RESULTS: Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81–0.98). Good correlations were found for the distance with coronary ostia(0.75–0.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89 and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus 3.14 min), respectively. CONCLUSIONS: Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience. ADVANCES IN KNOWLEDGE: The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow. |
format | Online Article Text |
id | pubmed-10461289 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The British Institute of Radiology. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104612892023-08-29 Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience Annoni, Andrea Daniele Mancini, Maria Elisabetta Carlicchi, Eleonora Belmonte, Marta Formenti, Alberto Mushtaq, Saima Marchetti, Francesca Cilia, Francesco Baggiano, Andrea Fusini, Laura Bonomi, Alice Gennari, Marco Montorsi, Piero Pepi, Mauro Pontone, Gianluca Br J Radiol Full Paper OBJECTIVES: Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators. METHODS: Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with >5 years and 1 year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared. RESULTS: Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81–0.98). Good correlations were found for the distance with coronary ostia(0.75–0.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89 and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus 3.14 min), respectively. CONCLUSIONS: Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience. ADVANCES IN KNOWLEDGE: The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow. The British Institute of Radiology. 2023-09 2023-07-25 /pmc/articles/PMC10461289/ /pubmed/37449675 http://dx.doi.org/10.1259/bjr.20220733 Text en © 2023 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Full Paper Annoni, Andrea Daniele Mancini, Maria Elisabetta Carlicchi, Eleonora Belmonte, Marta Formenti, Alberto Mushtaq, Saima Marchetti, Francesca Cilia, Francesco Baggiano, Andrea Fusini, Laura Bonomi, Alice Gennari, Marco Montorsi, Piero Pepi, Mauro Pontone, Gianluca Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title | Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title_full | Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title_fullStr | Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title_full_unstemmed | Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title_short | Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
title_sort | pre-tavi aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience |
topic | Full Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461289/ https://www.ncbi.nlm.nih.gov/pubmed/37449675 http://dx.doi.org/10.1259/bjr.20220733 |
work_keys_str_mv | AT annoniandreadaniele pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT mancinimariaelisabetta pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT carlicchieleonora pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT belmontemarta pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT formentialberto pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT mushtaqsaima pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT marchettifrancesca pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT ciliafrancesco pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT baggianoandrea pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT fusinilaura pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT bonomialice pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT gennarimarco pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT montorsipiero pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT pepimauro pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience AT pontonegianluca pretaviaorticannulussizingcomparisonbetweenmanualandsemiautomatednewgenerationsoftwaremeasurementsinoperatorswithdifferentexperience |