Cargando…

Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature

Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intuba...

Descripción completa

Detalles Bibliográficos
Autores principales: Assiri, Abdullah M, Alhelali, Abdullah, AL-Benhassan, Ibrahim, Abo Hamed, Saeed, Alkathiri, Assaf, Miskeen, Elhadi, Alqarny, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461753/
https://www.ncbi.nlm.nih.gov/pubmed/37645239
http://dx.doi.org/10.2147/IMCRJ.S414298
_version_ 1785097907591970816
author Assiri, Abdullah M
Alhelali, Abdullah
AL-Benhassan, Ibrahim
Abo Hamed, Saeed
Alkathiri, Assaf
Miskeen, Elhadi
Alqarny, Mohammed
author_facet Assiri, Abdullah M
Alhelali, Abdullah
AL-Benhassan, Ibrahim
Abo Hamed, Saeed
Alkathiri, Assaf
Miskeen, Elhadi
Alqarny, Mohammed
author_sort Assiri, Abdullah M
collection PubMed
description Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intubation can guide the ETT through the vocal cords. However, complications can arise when the stylet is not removed after successful intubation. Herewith, we reported a patient who was two years old and suffered from respiratory failure. However, in the first 12 hours, we observed a foreign body in the trachea, a small end of a metal stylet immediately removed by bronchoscope. This case demonstrates that multiple uses of a stylet, especially by a single user, can result in impaction of the stylet in the ETT during intubation, requiring force when the stylet is withdrawn after intubation, which can result in breakage, shearing, and retention of the stylet or plastic sheath in the lumen of the ETT.
format Online
Article
Text
id pubmed-10461753
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-104617532023-08-29 Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature Assiri, Abdullah M Alhelali, Abdullah AL-Benhassan, Ibrahim Abo Hamed, Saeed Alkathiri, Assaf Miskeen, Elhadi Alqarny, Mohammed Int Med Case Rep J Case Report Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intubation can guide the ETT through the vocal cords. However, complications can arise when the stylet is not removed after successful intubation. Herewith, we reported a patient who was two years old and suffered from respiratory failure. However, in the first 12 hours, we observed a foreign body in the trachea, a small end of a metal stylet immediately removed by bronchoscope. This case demonstrates that multiple uses of a stylet, especially by a single user, can result in impaction of the stylet in the ETT during intubation, requiring force when the stylet is withdrawn after intubation, which can result in breakage, shearing, and retention of the stylet or plastic sheath in the lumen of the ETT. Dove 2023-08-24 /pmc/articles/PMC10461753/ /pubmed/37645239 http://dx.doi.org/10.2147/IMCRJ.S414298 Text en © 2023 Assiri et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Case Report
Assiri, Abdullah M
Alhelali, Abdullah
AL-Benhassan, Ibrahim
Abo Hamed, Saeed
Alkathiri, Assaf
Miskeen, Elhadi
Alqarny, Mohammed
Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title_full Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title_fullStr Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title_full_unstemmed Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title_short Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
title_sort partial obstruction of the endotracheal tube by a part of the metallic stylet; case report and review of the literature
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461753/
https://www.ncbi.nlm.nih.gov/pubmed/37645239
http://dx.doi.org/10.2147/IMCRJ.S414298
work_keys_str_mv AT assiriabdullahm partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT alhelaliabdullah partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT albenhassanibrahim partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT abohamedsaeed partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT alkathiriassaf partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT miskeenelhadi partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature
AT alqarnymohammed partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature