Cargando…
Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature
Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intuba...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461753/ https://www.ncbi.nlm.nih.gov/pubmed/37645239 http://dx.doi.org/10.2147/IMCRJ.S414298 |
_version_ | 1785097907591970816 |
---|---|
author | Assiri, Abdullah M Alhelali, Abdullah AL-Benhassan, Ibrahim Abo Hamed, Saeed Alkathiri, Assaf Miskeen, Elhadi Alqarny, Mohammed |
author_facet | Assiri, Abdullah M Alhelali, Abdullah AL-Benhassan, Ibrahim Abo Hamed, Saeed Alkathiri, Assaf Miskeen, Elhadi Alqarny, Mohammed |
author_sort | Assiri, Abdullah M |
collection | PubMed |
description | Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intubation can guide the ETT through the vocal cords. However, complications can arise when the stylet is not removed after successful intubation. Herewith, we reported a patient who was two years old and suffered from respiratory failure. However, in the first 12 hours, we observed a foreign body in the trachea, a small end of a metal stylet immediately removed by bronchoscope. This case demonstrates that multiple uses of a stylet, especially by a single user, can result in impaction of the stylet in the ETT during intubation, requiring force when the stylet is withdrawn after intubation, which can result in breakage, shearing, and retention of the stylet or plastic sheath in the lumen of the ETT. |
format | Online Article Text |
id | pubmed-10461753 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-104617532023-08-29 Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature Assiri, Abdullah M Alhelali, Abdullah AL-Benhassan, Ibrahim Abo Hamed, Saeed Alkathiri, Assaf Miskeen, Elhadi Alqarny, Mohammed Int Med Case Rep J Case Report Endotracheal intubation is common in the emergency department, intensive care units, and operating rooms. It involves the insertion of an endotracheal tube (ETT) through the mouth or nose into the trachea to maintain a patent airway and facilitate mechanical ventilation. Using a stylet during intubation can guide the ETT through the vocal cords. However, complications can arise when the stylet is not removed after successful intubation. Herewith, we reported a patient who was two years old and suffered from respiratory failure. However, in the first 12 hours, we observed a foreign body in the trachea, a small end of a metal stylet immediately removed by bronchoscope. This case demonstrates that multiple uses of a stylet, especially by a single user, can result in impaction of the stylet in the ETT during intubation, requiring force when the stylet is withdrawn after intubation, which can result in breakage, shearing, and retention of the stylet or plastic sheath in the lumen of the ETT. Dove 2023-08-24 /pmc/articles/PMC10461753/ /pubmed/37645239 http://dx.doi.org/10.2147/IMCRJ.S414298 Text en © 2023 Assiri et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Case Report Assiri, Abdullah M Alhelali, Abdullah AL-Benhassan, Ibrahim Abo Hamed, Saeed Alkathiri, Assaf Miskeen, Elhadi Alqarny, Mohammed Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title | Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title_full | Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title_fullStr | Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title_full_unstemmed | Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title_short | Partial Obstruction of the Endotracheal Tube by a Part of the Metallic Stylet; Case Report and Review of the Literature |
title_sort | partial obstruction of the endotracheal tube by a part of the metallic stylet; case report and review of the literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10461753/ https://www.ncbi.nlm.nih.gov/pubmed/37645239 http://dx.doi.org/10.2147/IMCRJ.S414298 |
work_keys_str_mv | AT assiriabdullahm partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT alhelaliabdullah partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT albenhassanibrahim partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT abohamedsaeed partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT alkathiriassaf partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT miskeenelhadi partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature AT alqarnymohammed partialobstructionoftheendotrachealtubebyapartofthemetallicstyletcasereportandreviewoftheliterature |