Cargando…

Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser

OBJECTIVES: Inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS) are increasingly prevalent disorders. Faecal calprotectin is useful in the differential diagnosis of IBD from IBS and monitoring IBD activity. We verified the Bühlmann fCAL turbo faecal calprotectin assay on the Binding...

Descripción completa

Detalles Bibliográficos
Autores principales: Handley, S.A., Dote, N.P., Wanandy, T., Prentice, L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462488/
https://www.ncbi.nlm.nih.gov/pubmed/37649548
http://dx.doi.org/10.1016/j.plabm.2023.e00318
_version_ 1785098042647511040
author Handley, S.A.
Dote, N.P.
Wanandy, T.
Prentice, L.
author_facet Handley, S.A.
Dote, N.P.
Wanandy, T.
Prentice, L.
author_sort Handley, S.A.
collection PubMed
description OBJECTIVES: Inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS) are increasingly prevalent disorders. Faecal calprotectin is useful in the differential diagnosis of IBD from IBS and monitoring IBD activity. We verified the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site, Optilite benchtop analyser. DESIGN: Accuracy, precision, lower limit of quantitation (LLoQ), and linearity of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site, Optilite benchtop analyser were ascertained. Comparison with the Bühlmann Quantum Blue fCAL extended and DiaSorin, Liaison calprotectin assays were also undertaken. Difference between assays was evaluated using the Wilcoxon signed-rank test and method comparison was undertaken using Spearman’s rank correlation (rs), difference plots and Passing-Bablok regression analyses. RESULTS: The fCAL turbo assay was linear between 25 and 10,000 μg/g, and the LLoQ was 25 μg/g. Intra-, and inter-assay imprecision was <5%. There was a good agreement (rs = 0.96) and no significant bias (3%, p = 0.10) present between the fCAL turbo and Quantum Blue extended assays. Between the fCAL turbo and DiaSorin, liaison assays there was a good agreement (rs = 0.97), but a significant bias (53%, p = <0.01) was present. CONCLUSIONS: The fCAL turbo assay performs well on the Binding Site, Optilite benchtop analyser. Calprotectin results are commutable between with Bühlmann fCAL turbo and Quantum Blue fCAL extended assays, but not between Bühlmann and DiaSorin calprotectin assays.
format Online
Article
Text
id pubmed-10462488
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104624882023-08-30 Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser Handley, S.A. Dote, N.P. Wanandy, T. Prentice, L. Pract Lab Med Short Communication OBJECTIVES: Inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS) are increasingly prevalent disorders. Faecal calprotectin is useful in the differential diagnosis of IBD from IBS and monitoring IBD activity. We verified the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site, Optilite benchtop analyser. DESIGN: Accuracy, precision, lower limit of quantitation (LLoQ), and linearity of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site, Optilite benchtop analyser were ascertained. Comparison with the Bühlmann Quantum Blue fCAL extended and DiaSorin, Liaison calprotectin assays were also undertaken. Difference between assays was evaluated using the Wilcoxon signed-rank test and method comparison was undertaken using Spearman’s rank correlation (rs), difference plots and Passing-Bablok regression analyses. RESULTS: The fCAL turbo assay was linear between 25 and 10,000 μg/g, and the LLoQ was 25 μg/g. Intra-, and inter-assay imprecision was <5%. There was a good agreement (rs = 0.96) and no significant bias (3%, p = 0.10) present between the fCAL turbo and Quantum Blue extended assays. Between the fCAL turbo and DiaSorin, liaison assays there was a good agreement (rs = 0.97), but a significant bias (53%, p = <0.01) was present. CONCLUSIONS: The fCAL turbo assay performs well on the Binding Site, Optilite benchtop analyser. Calprotectin results are commutable between with Bühlmann fCAL turbo and Quantum Blue fCAL extended assays, but not between Bühlmann and DiaSorin calprotectin assays. Elsevier 2023-06-24 /pmc/articles/PMC10462488/ /pubmed/37649548 http://dx.doi.org/10.1016/j.plabm.2023.e00318 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Short Communication
Handley, S.A.
Dote, N.P.
Wanandy, T.
Prentice, L.
Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title_full Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title_fullStr Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title_full_unstemmed Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title_short Verification of the Bühlmann fCAL turbo faecal calprotectin assay on the Binding Site Optilite benchtop analyser
title_sort verification of the bühlmann fcal turbo faecal calprotectin assay on the binding site optilite benchtop analyser
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462488/
https://www.ncbi.nlm.nih.gov/pubmed/37649548
http://dx.doi.org/10.1016/j.plabm.2023.e00318
work_keys_str_mv AT handleysa verificationofthebuhlmannfcalturbofaecalcalprotectinassayonthebindingsiteoptilitebenchtopanalyser
AT dotenp verificationofthebuhlmannfcalturbofaecalcalprotectinassayonthebindingsiteoptilitebenchtopanalyser
AT wanandyt verificationofthebuhlmannfcalturbofaecalcalprotectinassayonthebindingsiteoptilitebenchtopanalyser
AT prenticel verificationofthebuhlmannfcalturbofaecalcalprotectinassayonthebindingsiteoptilitebenchtopanalyser