Cargando…
Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays
OBJECTIVES: To evaluate whether the routine coagulation tests can be performed using platelet depleted plasma (PDP, residual platelet count <40000/μL) to achieve maximum efficiency of the automated workflow and compare results of these tests performed with platelet poor plasma (PPP residual plate...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462667/ https://www.ncbi.nlm.nih.gov/pubmed/37649543 http://dx.doi.org/10.1016/j.plabm.2023.e00324 |
_version_ | 1785098081853767680 |
---|---|
author | Barbhuiya, Mustafa A. Livingston, Ron Baranoski, Sue Creer, Michael H Oladipo, Olajumoke |
author_facet | Barbhuiya, Mustafa A. Livingston, Ron Baranoski, Sue Creer, Michael H Oladipo, Olajumoke |
author_sort | Barbhuiya, Mustafa A. |
collection | PubMed |
description | OBJECTIVES: To evaluate whether the routine coagulation tests can be performed using platelet depleted plasma (PDP, residual platelet count <40000/μL) to achieve maximum efficiency of the automated workflow and compare results of these tests performed with platelet poor plasma (PPP residual platelet count <10,000/μL) prepared manually ‘offline’. DESIGN AND METHODS: The PDP was obtained first following ‘on line’ centrifugation at 4150 RPM (3000g) for 7 min. The routine coagulation tests, Prothrombin Time (PT), Activated Partial Thromboplastin Clotting Time (aPTT), D-dimer (DD), Antithrombin III (AT3) and Fibrinogen (FBG) were performed. The PPP was obtained from an aliquot of PDP samples with additional ‘manual off line’ centrifugation at 7700 RPM (3314g) for 3 min (total 10 min, online + offline) and the same tests were performed. The statistical analysis was carried out using EP Evaluator v11 to compare results from both methods. RESULTS: The results from both PPP and PDP samples demonstrated strong correlation. For example, PT (R = 0.9989; N = 55, and of Bias −0.12 (−0.67%), aPTT(R = 0.9957; N = 60, Bias 0.26 (0.58%)), AT3(R = 0.9800; N = 49, Bias −2.0 (−2.2%)), FBG (R = 0.9956; N = 57, Bias −1.9 (−0.5%)) and DD (R = 0.9981; N = 38, Bias 0.005 (0.373%)) with insignificant bias. CONCLUSIONS: The utilization of the Roche cobas® 8100 automated ‘online’ centrifugation helps achieve optimal workflow efficiency without impacting analytical performance of the PT, aPTT, DD, AT3 and FBG assays. The use of PDP can be superior method to PPP for routine coagulation tests. |
format | Online Article Text |
id | pubmed-10462667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104626672023-08-30 Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays Barbhuiya, Mustafa A. Livingston, Ron Baranoski, Sue Creer, Michael H Oladipo, Olajumoke Pract Lab Med Short Communication OBJECTIVES: To evaluate whether the routine coagulation tests can be performed using platelet depleted plasma (PDP, residual platelet count <40000/μL) to achieve maximum efficiency of the automated workflow and compare results of these tests performed with platelet poor plasma (PPP residual platelet count <10,000/μL) prepared manually ‘offline’. DESIGN AND METHODS: The PDP was obtained first following ‘on line’ centrifugation at 4150 RPM (3000g) for 7 min. The routine coagulation tests, Prothrombin Time (PT), Activated Partial Thromboplastin Clotting Time (aPTT), D-dimer (DD), Antithrombin III (AT3) and Fibrinogen (FBG) were performed. The PPP was obtained from an aliquot of PDP samples with additional ‘manual off line’ centrifugation at 7700 RPM (3314g) for 3 min (total 10 min, online + offline) and the same tests were performed. The statistical analysis was carried out using EP Evaluator v11 to compare results from both methods. RESULTS: The results from both PPP and PDP samples demonstrated strong correlation. For example, PT (R = 0.9989; N = 55, and of Bias −0.12 (−0.67%), aPTT(R = 0.9957; N = 60, Bias 0.26 (0.58%)), AT3(R = 0.9800; N = 49, Bias −2.0 (−2.2%)), FBG (R = 0.9956; N = 57, Bias −1.9 (−0.5%)) and DD (R = 0.9981; N = 38, Bias 0.005 (0.373%)) with insignificant bias. CONCLUSIONS: The utilization of the Roche cobas® 8100 automated ‘online’ centrifugation helps achieve optimal workflow efficiency without impacting analytical performance of the PT, aPTT, DD, AT3 and FBG assays. The use of PDP can be superior method to PPP for routine coagulation tests. Elsevier 2023-07-14 /pmc/articles/PMC10462667/ /pubmed/37649543 http://dx.doi.org/10.1016/j.plabm.2023.e00324 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Barbhuiya, Mustafa A. Livingston, Ron Baranoski, Sue Creer, Michael H Oladipo, Olajumoke Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title | Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title_full | Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title_fullStr | Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title_full_unstemmed | Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title_short | Comparative analysis of platelet depleted plasma prepared on the Roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
title_sort | comparative analysis of platelet depleted plasma prepared on the roche 8100 automation line and manually centrifuged platelet poor plasma for routine coagulation assays |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462667/ https://www.ncbi.nlm.nih.gov/pubmed/37649543 http://dx.doi.org/10.1016/j.plabm.2023.e00324 |
work_keys_str_mv | AT barbhuiyamustafaa comparativeanalysisofplateletdepletedplasmapreparedontheroche8100automationlineandmanuallycentrifugedplateletpoorplasmaforroutinecoagulationassays AT livingstonron comparativeanalysisofplateletdepletedplasmapreparedontheroche8100automationlineandmanuallycentrifugedplateletpoorplasmaforroutinecoagulationassays AT baranoskisue comparativeanalysisofplateletdepletedplasmapreparedontheroche8100automationlineandmanuallycentrifugedplateletpoorplasmaforroutinecoagulationassays AT creermichaelh comparativeanalysisofplateletdepletedplasmapreparedontheroche8100automationlineandmanuallycentrifugedplateletpoorplasmaforroutinecoagulationassays AT oladipoolajumoke comparativeanalysisofplateletdepletedplasmapreparedontheroche8100automationlineandmanuallycentrifugedplateletpoorplasmaforroutinecoagulationassays |