Cargando…

Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study

OBJECTIVE: The real-time PCR system is one of the most powerful research tools available in the life sciences field. The aim of this study was to preliminarily evaluate the analytical performance of QuantStudio 1 Plus real-time PCR system (QS 1 plus) for clinical procedures. METHODS: The consistency...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Ziran, Yi, Jie, Yu, Qi, Liu, Yiwei, Zhang, Rui, Zhang, Dong, Yang, Wenhang, Xu, Yingchun, Chen, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462677/
https://www.ncbi.nlm.nih.gov/pubmed/37649547
http://dx.doi.org/10.1016/j.plabm.2023.e00330
_version_ 1785098083963502592
author Wang, Ziran
Yi, Jie
Yu, Qi
Liu, Yiwei
Zhang, Rui
Zhang, Dong
Yang, Wenhang
Xu, Yingchun
Chen, Yu
author_facet Wang, Ziran
Yi, Jie
Yu, Qi
Liu, Yiwei
Zhang, Rui
Zhang, Dong
Yang, Wenhang
Xu, Yingchun
Chen, Yu
author_sort Wang, Ziran
collection PubMed
description OBJECTIVE: The real-time PCR system is one of the most powerful research tools available in the life sciences field. The aim of this study was to preliminarily evaluate the analytical performance of QuantStudio 1 Plus real-time PCR system (QS 1 plus) for clinical procedures. METHODS: The consistency of QS 1 plus with the reference system in terms of various clinical procedures was evaluated. For qualitative data, the Kappa test was used to analyze the agreement of the results. For the quantitative data, Passing-Bablok regression analysis and Bland-Altman plot analysis were used to assess the concordance between QS 1 plus and the reference instrument. RESULTS: Passing-Bablok regression showed an excellent agreement between the QS 1 plus and LC 480 systems for HBV DNA quantification (y = 0.928 + 0.970x), whereas Bland-Altman plot analysis showed very small mean deviations between the two systems. The QS 1 plus yielded perfectly consistent results with the reference instrument for methylenetetrahydrofolate reductase (MTHFR) C677T melting curve genotyping analysis, MTHFR C677T genotyping analysis, Norovirus RNA negative/positive analysis, influenza B virus (Flu B) RNA negative/positive analysis, Mycobacterium tuberculosis (MTB) DNA negative/positive analysis, Human Papillomavirus (HPV) genotyping analysis, epidermal growth factor receptor (EGFR) gene mutation analysis. Both the relative quantitative analysis and the relative quantitative analysis (standard curve) confirmed the satisfactory concordance between the QS 1 plus instrument and the ABI 7500 instrument by Passing-Bablok regression analysis (y = 0.180 + 0.817x and y = 0.012 + 1.000x, respectively) and Bland-Altman plot analysis. CONCLUSIONS: Our research has proven that QS 1 plus is adaptable to most test procedures in the clinical laboratory. This may provide the basis for its further application.
format Online
Article
Text
id pubmed-10462677
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104626772023-08-30 Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study Wang, Ziran Yi, Jie Yu, Qi Liu, Yiwei Zhang, Rui Zhang, Dong Yang, Wenhang Xu, Yingchun Chen, Yu Pract Lab Med Original Research Article OBJECTIVE: The real-time PCR system is one of the most powerful research tools available in the life sciences field. The aim of this study was to preliminarily evaluate the analytical performance of QuantStudio 1 Plus real-time PCR system (QS 1 plus) for clinical procedures. METHODS: The consistency of QS 1 plus with the reference system in terms of various clinical procedures was evaluated. For qualitative data, the Kappa test was used to analyze the agreement of the results. For the quantitative data, Passing-Bablok regression analysis and Bland-Altman plot analysis were used to assess the concordance between QS 1 plus and the reference instrument. RESULTS: Passing-Bablok regression showed an excellent agreement between the QS 1 plus and LC 480 systems for HBV DNA quantification (y = 0.928 + 0.970x), whereas Bland-Altman plot analysis showed very small mean deviations between the two systems. The QS 1 plus yielded perfectly consistent results with the reference instrument for methylenetetrahydrofolate reductase (MTHFR) C677T melting curve genotyping analysis, MTHFR C677T genotyping analysis, Norovirus RNA negative/positive analysis, influenza B virus (Flu B) RNA negative/positive analysis, Mycobacterium tuberculosis (MTB) DNA negative/positive analysis, Human Papillomavirus (HPV) genotyping analysis, epidermal growth factor receptor (EGFR) gene mutation analysis. Both the relative quantitative analysis and the relative quantitative analysis (standard curve) confirmed the satisfactory concordance between the QS 1 plus instrument and the ABI 7500 instrument by Passing-Bablok regression analysis (y = 0.180 + 0.817x and y = 0.012 + 1.000x, respectively) and Bland-Altman plot analysis. CONCLUSIONS: Our research has proven that QS 1 plus is adaptable to most test procedures in the clinical laboratory. This may provide the basis for its further application. Elsevier 2023-08-14 /pmc/articles/PMC10462677/ /pubmed/37649547 http://dx.doi.org/10.1016/j.plabm.2023.e00330 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Wang, Ziran
Yi, Jie
Yu, Qi
Liu, Yiwei
Zhang, Rui
Zhang, Dong
Yang, Wenhang
Xu, Yingchun
Chen, Yu
Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title_full Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title_fullStr Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title_full_unstemmed Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title_short Performance evaluation of QuantStudio 1 plus real-time PCR instrument for clinical laboratory analysis: A proof-of-concept study
title_sort performance evaluation of quantstudio 1 plus real-time pcr instrument for clinical laboratory analysis: a proof-of-concept study
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462677/
https://www.ncbi.nlm.nih.gov/pubmed/37649547
http://dx.doi.org/10.1016/j.plabm.2023.e00330
work_keys_str_mv AT wangziran performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT yijie performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT yuqi performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT liuyiwei performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT zhangrui performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT zhangdong performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT yangwenhang performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT xuyingchun performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy
AT chenyu performanceevaluationofquantstudio1plusrealtimepcrinstrumentforclinicallaboratoryanalysisaproofofconceptstudy